• 제목/요약/키워드: 3D body scan measurement

검색결과 54건 처리시간 0.022초

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교- (Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-)

  • 백경자;이정란
    • 한국의류학회지
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

한국 청소년의 대표 인체치수 및 3D 인체형상자료에 관한 연구 (Studies on Representative Body Sizes and 3D Body Scan Data of Korean Adolescents)

  • 최승일
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.227-232
    • /
    • 2016
  • 3D 인체형상자료는 인체 적합성이 우수한 제품과 생활공간을 만들기 위해 다양한 분야에서 활용되고 있다. 본 연구는 한국인 인체치수조사 보급사업에서 2013년에 수집한 청소년층 3차원 측정 자료를 기반으로 한국 청소년의 대표 인체치수를 산출하고 대표 인체치수와 가까운 3D 인체형상자료를 선별하는 방법을 제공한다. 먼저 여러 측정항목으로 이루어진 다차원 벡터공간을 요인분석을 통해 둘레성분과 길이성분의 2차원 벡터공간으로 투영하였다. 다음으로 2차원 성분공간에서 마할라노비스 거리를 이용하여 대표 인체치수와 이에 가까운 3D 인체형상자료를 선별하였다. 2차원 성분공간에 나타난 청소년기의 성장패턴을 고려하여 남자는 4개의 연령그룹으로 여자는 3개의 연령그룹으로 구분하였다. 성분점수 계수행렬의 열벡터에 대응하는 고유형상을 이용하여 남자는 13개 측정항목, 여자는 14개 측정항목에 대한 대표 인체치수를 연령그룹별로 계산하였다. 여기서 구한 대표 인체치수와 3D 인체형상자료는 3차원 대표 형상을 만드는 데에 매우 유용하다.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석 (Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring)

  • ;임호선;천종숙
    • 복식문화연구
    • /
    • 제19권6호
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Analysis of Body Measurement and Type using 3D Body Scan Data - Adult men and women in their 20's~30's in the 6th Size Korea project -

  • Lim, Ho-Sun;Park, Chang-Kyu
    • 패션비즈니스
    • /
    • 제15권6호
    • /
    • pp.85-100
    • /
    • 2011
  • The objective of this study was to analyze body measurements, BMI and body type according to age in the male and female groups based on 3D scan body measurement data of adult men and women in their 20's~30's and to provide basic information usable in the clothing and fashion industry. For this purpose, we analyzed 3D scan body measurement data of 848 adults measured in the 6th Size Korea project and the results were as follows. First, there were differences in 3D scan body measurements according to age in the male and female groups, and in general the measurements of the height items were larger in younger adults and the measurements of the circumference, breadth and depth items were larger in older ones. Second, there were differences in 3D scan body measurements according to BMI in the male and female groups, and in general body measurements were largest in the obesity group and lowest in the underweight group. Third, BMI was different according to gender and in general BMI was higher in men and obesity and overweight were more frequent in men than in women. Moreover, BMI was significantly different according to age and was higher in the 30's than in the 20's. Fourth, the mean difference in the drop and lower drop values according to age in the male and female groups was significant, and the drop and lower drop values were lower in the 30's than in the 20's. These results are considered meaningful as data for the development of clothing size systems, patterns and grading in the areas of clothing and fashion targeting consumers in their 20's~30's.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • 대한인간공학회지
    • /
    • 제33권4호
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

A Study on the Setting of Breast Measurement Points on 3D Scan Data

  • Sohn, Boo-Hyun;Han, Hyun-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권5호
    • /
    • pp.81-90
    • /
    • 2020
  • 직접 측정방법을 기반으로 3차원 스캔 데이터에서 유방의 자동측정을 위한 유방과 관련된 측정점 설정과 이상적인 3차원 스캔 자세를 제안하였다. 특히 직접 측정법에서의 유방 바깥쪽점은 체형과 자세에 따라 변동되기 쉬우므로 3차원 측정법에서는 유방에서 찾는 새로운 방법을 제안하였다. 유방의 윤곽선이 뚜렷하지 않은 유방 위쪽의 유방 위쪽점은 겨드랑접힘점을 기준으로 설정되는데 직접측정법에서의 유방 위쪽점이 3차원 스캔데이터에서 측정된 유방위쪽점보다 높게 설정됨을 알 수 있었다. 그러므로 직접 측정치와 3차원 측정치 간의 오차를 줄이기 위해서는 유방 위쪽점 설정에 관여되는 겨드랑앞접힘점 위치가 명확해야 할 것이다. 유방과 관련된 깊이 항목에서는 유방 바깥쪽점을 제외한 모든 깊이에서 직접 측정치가 높게 나타났는데 이는 피부 눌림에 의한 것으로 판단된다. 또 유방의 굴곡이 심한 유방아래길이와 유방아래 접힘선길이, 유방 안쪽점사이 간격은 굴곡에 의해 3차원 측정치가 직접 측정치보다 높게 나타나 유방에 대한 3차원 측정법이 일반화되기 위해서는 다양한 유방유형에 따른 측정치의 변화를 연구할 필요가 있다.

A Study on Use of Anthropometric Data and 3D Body Scan Data at Apparel Industry

  • Chun, Jongsuk
    • The International Journal of Costume Culture
    • /
    • 제6권1호
    • /
    • pp.19-29
    • /
    • 2003
  • The 3D measurement data expected be useful to give appropriate garment fit and development of MTM(Made-to-Measure) CAD software. The researcher surveyed the need and use of national anthropometric data of the apparel industry. 17 Korean apparel manufacturers participated in the study. The need of anthropometric data at 5 different apparel business sectors was measured: men's suit, women's dress, casual-wear, underwear, and active sportswear. The result of the survey shows that height and bust, waist, hip circumferences are needed by all of the business sectors. The body measurements at the scye and upper arm area were need most by the men's suit manufacturers. The women's foundation garment manufacturers were well prepared for the use of the 3D body scan data and they expected the potential benefits of 3D body scan data would be great. The researcher also conducted a case study and found a pro and con of the using 3D body scan data for apparel product developing process. In the current stage of technical advance, a reasonable method was required to get nude like scan data for the women's foundation garment manufacturer. The researcher concluded that the apparel designer could use the 3D scan data for developing tremendous style garment design and pattern making.

  • PDF

Verification of the Accuracy of Photogrammetry in 3D Full-Body Scanning -A Case Study for Apparel Applications-

  • Eun Joo Ryu;Lu Zhang;Hwa Kyung Song
    • 한국의류학회지
    • /
    • 제47권1호
    • /
    • pp.137-151
    • /
    • 2023
  • Stationary 3D whole-body scanners generally require 5 to 20 seconds of scanning time and cannot effectively detect armpit and crotch areas. Therefore, this study aimed to analyze the accuracy of a photogrammetric technique using a multi-camera system. First, dimensional accuracy was analyzed using a mannequin scan, comparing the differences between the scan-derived measurements and the direct measurements, with an allowable tolerance of ISO 20685-1:2018. Only 2 of 59 measurement items (ankle height and upper arm circumference, specifically) exceeded the ISO 20685-1:2018 criteria. When compared with the results of the eight stationary whole-body scanners assessed by the literature, the photogrammetric technique was found to have the advantage of scanning the top of the head, armpit, and crotch areas clearly. Second, this study found the photogrammetric technique is suitable for obtaining the body scans because it can minimize the perform scanning, resulting in a reduction of measurement errors due to breathing and uncontrolled movements. The error rate of the photogrammetry method was much lower than that of stationary 3D whole-body scanners.

3D Scanner를 이용한 인체계측방법 및 플레어스커트의 착의형태평가방법에 관한 연구 (A Study on the Feasibility of the 3D Scanning Method of Body Measurement and Wearing Evaluation)

  • 김혜경;석은영;서추연
    • 한국의류학회지
    • /
    • 제24권6호
    • /
    • pp.895-906
    • /
    • 2000
  • The study planned to testify the accuracy of the 3D scanner through analyzing the human body measurement method and the evaluation of flare skirt with 3D scanner. The results obtained from this study were as follows; First, the results of measurement for the dress form and human body by 3D scanner were more accurate than one or two dimensional measurement method. Second, from the results of the scan for the flare skirts as worn the human body, we could obtain very accurate horizontal section map. Third, in the clothing ergonomics viewpoint, the accuracy of the 3D scanner was very excellent and its utility was higher than that of the moir photography method. Therefore, the 3D scanner is very useful for the human body measurement and the wearing evaluation. In a nutshell, this study illustrates that we have to develop a program of automatic human body measurement system which will enhance the application of the 3D scanner.

  • PDF