• Title/Summary/Keyword: 60 Hz

Search Result 1,298, Processing Time 0.029 seconds

Study of 60Hz Transformer-less High Frequency Linked Grid-Connected Power Conditioners for Photovoltaic Power System (60Hz 절연변압기가 없는 고주파링크방식 계통연계형 태양광발전시스템 고찰)

  • 유권종;정영석;최주엽
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.563-569
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency DC-DC converter, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter, and an AC filter. The 20kHz switched high frequency converter is used to generate bipolar PWM pulse, and the high frequency transformer transforms its voltage twice, which is subsequently rectified by diode bridge rectifiers for a full-wave rectified 60 Hz sine wave power output. Even though the high frequency link system needs more power semiconductors, a reduced size, light weight, and saved parts cost make this system more comparative than other power conditioning systems due to elimination of 60Hz transformer.

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

A Study on the Characteristics of Cooperating Charge considering Dominant Frequency (주 주파수를 고려한 협동장약 특성에 관한 연구)

  • Kim Jong-In;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.316-323
    • /
    • 2005
  • As a result of waveform analysis, the separation of waveform found that high frequency well accomplishes but low frequency doesn't accomplish that. The data which measured less than 60 Hz and more than 60 Hz was analysed to examine the relation between cooperating charge and frequency. The measured data of more than 70 Hz was also analysed to consider the characteristics of high frequency.

A study on the combination of tests on circuit breakers at 50Hz and 60Hz (차단기의 50/60Hz공용주파수 정격의 시험방법에 관한 검토)

  • Suh Yoon Taek;Park Seung Jae;Lee Yong Han;Kim Maeng Hyun;Yun Hak Dong;Kim Dae Won
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.630-632
    • /
    • 2004
  • 본 논문에서는 전력 계통에서 보호기기로 사용되는 차단기의 50/60Hz 공용주파수 정격의 시험방법에 대하여 기술하였다. 그 과정으로 차단기의 개발시험 항목에 대한 시험목적, 전류투입차단시 차단기에 미치는 영향 및 국제적으로 적용되고 있는 관련 적용규격을 고찰하고 50 Hz 및 60 Hz 공용정격으로서 성능을 검증할 수 있는 방안을 제시한다.

  • PDF

Construction and Performance of Magnetically Shielded Room for Biomagnetic Applications (생체자기계측을 위한 자기차폐실의 설치 및 특성)

  • 이용호;권혁찬;김진목;임청무;이상길;박용기;박종철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.264-271
    • /
    • 1996
  • A magnetically shielded room has been constructed for biomagnetic applications. The room has internal dimensions of $2\;m(length){\times}2\;m(width){\times}2.5\;m(height)$ and it consists of high permeability Mumetal and high conductivity alummum, utilizing ferromagnetic shielding and eddy current shielding. The de shielding factor around the center of the room is above 60 dB, and the ac shielding factors at 1 and 10 Hz are larger than 60 and 80 dB, respectively. The internal magnetic field noise at 1 Hz is $500\;fT/{\sqrt}Hz$ and at 10 Hz is $100\;fT/{\sqrt}Hz$, and the field gradient noise at 1 Hz is below $7\;fT/cm{\sqrt}Hz$. Successful measurements of cardiomagnetic fields usmg SQUID magnetometer and neuromagnetic fields using SQUID gradiometer have been done.

  • PDF

The Effects of Laser Beam Stimulation on Blood Status and Concentration of Endocrine Substances in Dogs (레이저광선자극이 개의 혈액상과 내분비물질의 혈중농도에 미치는 영향)

  • 조용성;차용호
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.208-214
    • /
    • 1997
  • The objective of this study was (a) to examine the change of bloodchemistry and (b) to investigate the secretion trend of endocrinological substance in a dog model after laser-beam radiation at different level of frequency (250 Hz, 2,000 Hz, 5,000 Hz and 8,000 Hz). The experimental groups were divided into four groups were divided into four groups on the basis of the level of frequency radiated and stimulated for five minutes. Before stimulation and after a lapse of time (10-minute, 30-minute and 60-minute) all dogs were checked the following parameters; cortisol, ACTH, RBC, hemoglobin, hematocrit, WBC, Ca, P, ALT, AST and creatinine. The results were as follow: ten minutes after stimulation, cortisol level of 250 Hz group, 2,000 Hz group, 5,000 Hz group and 8,000 Hz group was increased 18.8%, 20.5%, 23.2% and 309%, respectively. Ten minutes after stimulation, ACTH level of 250 Hz group, 2,000 Hz group, 5,000 Hz group and 8,000 Hz group was increased 26.7%, 26.6%, 30.5% and 29.5%, respectively. It began to decrease and at 30-minute after stimulation resturned to pre-stimulation level at 60-minute after stimulation. In blood examination RBC, hemaoglobin, hematocrit and WBC level showed slight increase and decrease and returned to pre-stimulation level at 60-minute after radiation. In bloodchemical examination serum calcium, inorganic phosphorus, ALT, AST and creatinine level were within normal physiological ranges.

  • PDF

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.

Design of a 60 Hz Band Rejection FilterInsensitive to Component Tolerances (부품 허용 오차에 둔감한 60Hz 대역 억제 필터 설계)

  • Cheon, Jimin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2022
  • In this paper, we propose a band rejection filter (BRF) with a state variable filter (SVF) structure to effectively remove the influence of 60 Hz line frequency noise introduced into the sensor system. The conventional BRF of the SVF structure uses an additional operational amplifier (OPAMP) to add a low pass filter (LPF) output and a high pass filter (HPF) output or an input signal and a band pass filter. Therefore, the notch frequency and the notch depth that determine the signal attenuation of the BRF greatly depend on the tolerance of the resistors used to obtain the sum or difference of the signals. On the other hand, in the proposed BRF, since the BRF output is formed naturally within the SVF structure, there is no need for a combination between each port. The notch frequency of the proposed BRF is 59.99 Hz, and it can be confirmed that it is not affected at all by the tolerance of the resistor through the Monte Carlo simulation results. The notch depth also has an average of -42.54dB and a standard deviation of 0.63dB, confirming that normal operation as a BRF is possible. Also, with the proposed BRF, noise filtering was applied to the electrocardiogram (ECG) signal that interfered with 60 Hz noise, and it was confirmed that the 60 Hz noise was appropriately suppressed.