• Title/Summary/Keyword: AC

Search Result 8,831, Processing Time 0.037 seconds

Removal Characteristics of Phenol at Advanced Oxidation Process with Ozone/Activated Carbon Impregnated Metals (오존/촉매 산화공정에서 금속담지 활성탄을 이용한 페놀의 분해 특성)

  • Choi, Jae Won;Yoon, Ji Young;Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2012
  • Advanced oxidation processes (AOP) such as O3/activated carbon process and O3/catalysts process were used to compare the decomposition of phenol. Catalysts such as Pd/activated carbon (Pd/AC), Mn/activated carbon (Mn/AC), Co/activated carbon (Co/AC) and Fe/activated carbon (Fe/AC) were prepared by impregnation of Pd, Mn, Co and Fe into the activated carbon of pellet form, respectively. Based on an hour of reactions, the following descending order for the decomposition ratios of dissolved O3 to the 1.48 mg/L of saturated dissolved O3 was observed: Mn/AC (45%) > Pd/AC (42%) > Co/AC (33%) > AC (31%) > Fe/AC (27%). The removal efficiencies of phenol were also arranged in the descending order of AOP as follows: Mn/AC (89%) > Pd/AC (85%) > Co/AC (77%) > AC (76%) > Fe/AC (71%). The remaining ratios (C/Co) of TOC (total organic carbon) after an hour of experiments were arranged in the ascending order of AOP as follows : Pd/AC (0.29) < Mn/AC (0.36) < AC (0.40) < Co/AC (0.49) < Fe/AC (0.51). However, the catalytic effects in the Co/AC and the Fe/AC processes were little in comparison with O3/AC process. The maximum concentrations of intermediates such as hydroquinone and catechol formed from the decomposition of phenol were arranged in the ascending order of AOP as follows: Pd/AC < Fe/AC < Co/AC < AC < Mn/AC. In the case of Pd/AC process, these intermediates were almost disappeared after an one hour of reaction.

Study on Proximal Convergence/Accommodation(PC/A) Ratio by Comparison of Gradient AC/A Ratio and Calculated AC/A Ratio (Gradient AC/A비와 Calculated AC/A비의 비교에 의한 근접성 폭주비(PC/A)에 관한 연구)

  • Han, Gyeong-Ae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.223-231
    • /
    • 2004
  • In most previous studies, the assessment of accommodative convergence to accommodative stimulus (AC/A) ratio was commonly made by measuring gradient AC/A ratio. This study deals with the proximal convergence/accommodation(PC/A)ratio measured by comparing values of the gradient AC/A ratio and the calculated AC/A ratio to prevail the clinical use of the AC/A ratio. Visual acuities of All 124 subjects had been corrected to at least 1.0 with either eye through their habitual refractive correction and the MEM dynamic retinoscopy was performed to estimate their accommodative response. And then the PC/A ratio was calculated by making use of the calculated AC/A ratio and the gradient AC/A ratio. This study showed that the difference between the mean calculated AC/A ratio and the mean gradient AC/A ratio in subgroups may be attributable to proximal convergence. Consequently, further studies on proximity cues including the PC/A ratio could be helpful to prevail the clinical use of the AC/A ratio.

  • PDF

Static Characteristics Analysis of PWM Cuk AC-AC Converter for Power Quality Improvement of Custom Power (Custom Power의 전력품질 향상을 위한 PWM Cuk AC-AC 컨버터의 정적 특성 해석)

  • 최남섭
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.513-516
    • /
    • 2004
  • In this paper, a PWM Cuk AC-AC converter for power quality improvement of custom power is presented. The PWM Cuk AC-AC converter that is used in VVCF applications such as AC line conditioner, phase shifter is modelled by using complex circuit DQ transformation whereby the static characteristics equations such as voltage gain and power factor is analytically obtained. Finally, the PSIM simulation show the validity of the modelling and analysis.

  • PDF

Effluent and Aerobic Stability of Cellulase and LAB-Treated Silage of Napier Grass (Pennisetum purpureum Schum)

  • Zhang, J.;Kumai, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.8
    • /
    • pp.1063-1067
    • /
    • 2000
  • The effects of acremonium cellulase (AC) additive and lactic acid bacteria (LAB) inoculant on effluent production and aerobic stability of silage were investigated. Napier grass (Pennisetum purpureum Schum) was treated with AC at the rates of 0.05 ($AC_1$) and 0.1 g/kg $(AC_2)$ and/or with LAB at the rate of $1.0{\times}10^8cfu/kg$ fresh grass at ensiling. The treatments of LAB, $AC_1$, $AC_2$, $LAB+AC_1$ and $LAB+AC_2$ significantly (p<0.01) decreased pH and contents of volatile basic nitrogen and butyric acid, and significantly (p<0.01) increased lactic acid content compared with the control. All treated silages were well preserved with pH of lower than 4.2. There were no significant differences in fermentation quality between the application rates of AC ($AC_1$ and $AC_2$) and between the mixtures ($AC_1+LAB$ and $AC_2+LAB$). AC ($AC_1$ and $AC_2$) and AC plus LAB ($AC_1+LAB$ and $AC_2+LAB$) resulted in more silage effluent than the control and LAB inoculant alone. When the experimental silos were opened, the silages treated with AC and/or LAB were not as stable as the control silage, as shown by pH increase and lactic acid decomposition.

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

Analysis of REBA, RULA, OWAS of Wearing and Taking off Skinscuba Equipment for Prevention of Musculoskeletal Injuries (스킨스쿠버 장비 착용 및 벗는 자세의 근골격계 상해 예방을 위한 REBA, RULA, OWAS 분석)

  • Son, Sung-Min;Kim, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2011
  • The study was constructed an analysis of postures of a expert diver's wearing and taking off with skinscuba equipment using ergonomics tools(REBA, RULA, OWAS) for prevention of Musculoskeletal injuries. This survey is consisted of 4 postures in terms of wearing and taking off : Crouching(alone), Standing(alone), Helping of assistance, Using of stanchion. Their rate of injuries is getting higher due to instability postures, exposed dangers and excessive physical actions. So this study provides basic and educational information for prevention of that. The result is as follows : The result of crouching postures of wearing alone was REBA 9(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 2, and crouching postures of taking off alone was REBA 12(Ac Level 4), RULA 7(Ac Level 4), OWAS AC 4. The result of standing postures of wearing alone was REBA 8(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 3, and standing postures of taking off alone was REBA 8(Ac Level 3), RULA 7(Ac Level 4), OWAS AC 3. The result of helping of assistance postures of wearing was REBA 4(Ac Level 2), RULA 3(Ac Level 2), OWAS AC 2, and standing postures of taking off alone was REBA 4(Ac Level 2), RULA 4(Ac Level 2), OWAS AC 1. The result of using of stanchion postures of wearing was REBA 3(Ac Level 1), RULA 3(Ac Level 2), OWAS AC 1, and standing postures of taking off alone was REBA 3(Ac Level 1), RULA 3(Ac Level 2), OWAS AC 1. Especially both postures of wearing and taking off alone showed high results in the analysis of postures using ergonomics tools(REBA, RULA, OWAS).

Four quadrant output AC voltage control using a single quasi Z-source AC-AC converter (단일 Quasi Z-소스 AC-AC 컨버터에 의한 4상한 출력 AC전압 제어)

  • Eom, Jun-Hyun;Park, Hong-Soon;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.141-142
    • /
    • 2013
  • 본 논문에서는 단일 Quasi Z-소스 AC-AC 컨버터에 의한 4상한 출력 AC전압 제어를 제안하였다. 제안된 듀티비 제어방법을 통하여 한 대의 Quasi Z-소스 AC-AC 컨버터로도 동상의 벅-부스트 모드와 역상의 벅-부스트 모드를 모두 출력하는 4상한 출력 AC전압 제어를 하였다. 한 대의 Quasi Z-소스 AC-AC 컨버터만으로 종전의 듀티비 제어에 의해 동상의 부스트 모드와 역상의 벅-부스트 모드의 출력 전압이 발생되며, 제안한 듀티비 제어에 의해 동상의 벅 모드가 출력되는 4상한 출력 AC전압 제어법을 PSIM시뮬레이션에 의하여 입증하였다.

  • PDF

Geographical Variation in Sex Pheromone Composition of Adoxophyes spp. (Lepidoptera: Tortricidae) in Pear Orchards (배 과원에 발생하는 애모무늬잎말이나방 성페로몬 조성의 지리적 변이)

  • Yang Chang-Yeol;Jeon Heung-Yong;Boo Kyung-Saeng
    • Korean journal of applied entomology
    • /
    • v.44 no.1 s.138
    • /
    • pp.31-36
    • /
    • 2005
  • Adoxophyes spp. are the major rests of a pear. The larvae attack both leaves and fruits. (Z)-9-tetradecenyl acetate (Z9-14:Ac), (Z)-11-tetradecenyl acetate (Z11-14:Ac), (E)-11-tetradecenyl acetate (E11-14:Ac) and 10-methyldodecyl acetate (10me-12:Ac) have been reported as the sex pheromone components of the genus Adoxophyes. Our objective was to determine the difference in sex pheromone composition of three different A. spp. populations each from Cheonan, Sangju, and Naju area orchards in Korea. Gas chromatography (GC) analyses of pheromone gland extracts of virgin females confirmed the presence of two compounds (Z9-14:Ac and Z11-14:Ac) in Cheonan and Sangju populations, and four compounds (Z9-14:Ac, Z11-14:Ac, E11-14:Ac and tome-12:Ac) in Naju population. The Z9-14:Ac and Z11-14:Ac were detected in the ratio of 80:20 in the Cheonan population and 3:97 in the Sangju population. Females of Naju population produced sex pheromone blend consisting of Z9-14:Ac, Z11-14:Ac, E11-14:Ac and 10me-12:Ac at a ratio of 31:62:6:1. Field trapping tests in pear orchards with Z9-14:Ac and Z11-14:Ac indicated that maximum captures of the male were obtained with traps baited by 80:20 in Cheonan, 10:90 in Sangju, and 30:70 in Naju. These results suggest that there are remarkable geographical variations in the sex pheromone composition of A. spp. in pear orchards in Korea, and taxonomic classification of these species must be carefully assessed.

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Performance Comparison of Optimal Power Flow Algorithms for LMP Calculations of the Full Scale Korean Power System

  • Lee, Sungwoo;Kim, Wook;Kim, Balho H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.109-117
    • /
    • 2015
  • This paper proposes the comparison results of various optimal power flow algorithms (OPF) to calculate the locational marginal prices (LMP) of the unreduced full scale Korean transmission system. Five different types of optimal power flow models are employed: Full AC OPF, Cubic AC OPF, Quadratic AC OPF, Linear AC OPF and DC OPF. As the results, full AC OPF and cubic AC OPF model provides LMP calculation results very similar to each other while the calculation time of cubic AC OPF model is faster than that of the Full AC OPF. Other simplified OPF models, quadratic AC OPF, linear AC OPF and DC OPF offer erroneous results even though the calculation times are much faster than the Full AC OPF and the Cubic AC OPF. Given the condition that the OPF models sometimes fail to find the optimal solution due to the severe complexity of the Korean transmission power system, the Full AC OPF should be used as the primary OPF model while the Cubic AC OPF can be a promising backup OPF model for the LMP calculations and/or real-time operation.