• Title/Summary/Keyword: Absorbable suture material

Search Result 26, Processing Time 0.026 seconds

Comparison of Tracheal Anastomosis by Interrupted and Continuous Technique of Absorbable polydioxanone (PDS) Suture Material in Rabbit (가토에서 흡수성 PDS 봉합사의 단속봉합술식과 연속봉합술식에 따른 기관문합의 비교)

  • 이석열;양성린;이길노
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2001
  • Background: Tracheal resection and end-to-end anastomosis are the preferred treatment for tracheal tumor or tracheal stenosis. Absorbable suture material has been commonly used in case of tracheal anastomosis. But anastomosis technique is controversial. This experimental study compared between interrupted suture and continuous suture using Polydioxanone (PDS) absorbable suture material after tracheal resection and end-to-end anastomosis in rabbits. Methods : Twenty-four rabbits were used, divided into two groups of 12 animals each. The trachea was resected and then anastomosed with continuous 6-0 polydioxanone (PDS) (group 1), and intermittent 6-0 polydioxanone (PDS) (group 2). The animals were followed up for 6 months. Stenosis of the trachea was assessed at the time of death. Results : In two groups, anteroposterior diameter, transverse diameter, cross sectional area, and perimeter were greater in group 2 than in group 1 but, not significantly different. In addition, histologic findings were not different in two groups. Conclusions : This study suggest that stenosis after tracheal resection and end-to-end anastomosis using absorbable polydioxanone (PDS) suture material be not significantly different in both groups.

  • PDF

Fixation with Absorbable Suture Material in Akin Osteotomy (흡수성 봉합사를 이용한 무지외반증 Akin 절골술)

  • Song, Moo-Ho;Kim, Bu-Hwan;Ahn, Seong-Jun;Yoo, Seong-Ho;Lee, Doo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.149-152
    • /
    • 2011
  • Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also, any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.

Treatment of Achilles Tendon Rupture with Absorbable Suture (흡수성 봉합사를 이용한 아킬레스건 파열의 치료)

  • Kang, Chan;Hwang, Deuk-Soo;Hwang, Jung-Mo;Song, Jae-Hwang;Shin, Byung-Kon;Park, Jong-Hwa
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.3
    • /
    • pp.115-118
    • /
    • 2014
  • Purpose: The purpose of this study is to report on the result of repairing Achilles tendon using absorbable suture under nerve block. Materials and Methods: We retrospectively reviewed 20 patients with acute Achilles tendon rupture who were followed up for at least six months after the operation. We repaired Achilles tendon using two absorbable sutures using the Krackow technique for the proximal stump and the Kessler technique for the distal stump. A programmed postoperative management including non-weight bearing with a short leg cast for four weeks after the operation was applied for all patients. We evaluated clinical results using American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) for satisfaction, range of motion of ankle, functional recovery rate, and the starting time of single heel raise. Results: The mean VAS score for satisfaction and AOFAS score was 9.2 and 93.0, respectively. The affected ankle showed a mean dorsiflexion rate of 90% and plantar-flexion rate of 94% compared to the uninjured side. The single heel raise could start at a mean of 3.5 months after the operation. Conclusion: Treatment of Achilles tendon rupture with absorbable suture material using the hybrid suture technique of proximal Krackow and distal Kessler showed sufficient stability and minimal chronic inflammatory reaction.

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF

Importance of various skin sutures in cheiloplasty of cleft lip

  • Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.374-376
    • /
    • 2019
  • Last week, after our receiving online journal regarding Journal of the Korean Association of Oral and Maxillofacial Surgeons, we found a recently published original article by Alawode et al., entitled "A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures". Although this clinical article was well written and provided a great deal of information regarding the suture materials in the cleft lip repair, I would like to add a few additional comments based on the importance of skin suture during cheiloplasties in the primary cleft lip or secondary revision patients with representative figures.

Eyebrow Lift and Malar Fat Lift by Absorbable Suture Fixation with Subperiosteal Dissection (골막하 박리와 흡수성 봉합사에 의한 눈썹과 광대지방층의 거상술)

  • Chung, Jaehoon;Lee, Yoonhoo;Jang, Chunghyun
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.262-266
    • /
    • 2005
  • In some blepharochalasis patients, upper blepharoplasty alone is not satisfactory because of narrow distance between eyebrow and eyelash. On that occasion, eyebrow lift is advisable. There are many methods of classical eyebrow lift, such as direct excision, transblepharoplasty approach, anterior hairline technique, and so on. But they are not so effective, have a tendency to recur and also give rise to side effects; unacceptable scar, facial nerve palsy, sensory loss and hematoma, etc. Some patients who have prominent nasolabial folds, are reluctant to perform face lift procedure due to psychologic or economic burden. The authors performed the eyebrow lift procedure separately or simultaneously with face lift or forehead lift. After making 2 or 3 slit incisions, we passed absorbable suture material, 3-0 vicryl, through suborbicularis oculi fat layer. Then it was passed through subperiosteal plane and fixated to the temporalis fascia. When patients complain prominent nasolabial folds, malar fat pad was elevated also in the same manner. This methods is effective and has minimal complication such as facial nerve palsy, scar, sensory loss. Recurrent tendency was rarely observed during follow-up. Dimples were observed at slit incision sites but they disappeared within 2 or 3 weeks. Eyebrow lift and malar fat lift by absorbable suture elevation with subperiosteal dissection is a simple and less morbid. Because of its effectiveness and little side effect or complication, this procedure can be a useful method.

TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS (Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응)

  • Suh, Min-Jung;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study

  • Khiste, Sujeet Vinayak;Ranganath, V.;Nichani, Ashish Sham
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.3
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods: Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-${\epsilon}$-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results: During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions: 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10.