• Title/Summary/Keyword: Accuracy

Search Result 33,401, Processing Time 0.051 seconds

Comparative study in marginal accuracy of several all ceramic crowns (전부도재관의 변연 적합도 비교평가)

  • Kim, Jeong-Mi;Jeoung, Su-Ha
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

A Study on Forecast Accuracies by the Localized Land Forecast Areas over South Korea (육상 국지 예보 구역의 예보 정확도에 관한 연구)

  • Park, Chang-Yong;Choi, Young-Eun;Kim, Seung-Bae
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.1-14
    • /
    • 2007
  • This study aimed to evaluate weather forecast accuracies of minimum temperature, maximum temperature, precipitation and sky cover by the localized land forecast areas over South Korea Average forecast accuracy score of precipitation was the lowest while that of sky cover was the highest during the study period Overall forecast accuracy scores for Gangwon-do was the lowest while those for Gyeongsangnam-do and Gyeongsangbuk-do were higher than other areas. The frequencies of perfect forecast(eight points) by seasons, were the highest during winter and the lowest during summer. pressure pattern analyses for days when forecast accuracy scores were poor, showed that precipitation forecast accuracy scores were lower due to the movement of the stationary fronts during summers. When continental polar air masses expanded, forecast accuracy of temperature became greatly lower during autumns and winters As the migratory anticyclone pattern rapidly moved, forecast accuracy became lower during springs and autumns. Forecast accuracies were compared by wind directions at 850hPa for the Young-dong region where forecast accuracy was the lowest. Forecast accuracy scores on minimum and maximum temperatures were low when winds were westerlies and forecast accuracy scores of precipitation were low when winds were easterlies.

Investigation on the Accuracy of bundle Adjustments and Exterior Orientation Parameter Estimation of Linear Pushbroom Sensor Models (선형 푸시브룸 센서모델의 번들조정 정확도 및 외부표정요소추정 정확도 분석)

  • Kim Tae Jung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.2
    • /
    • pp.137-145
    • /
    • 2005
  • In this paper, we investigate the accuracy of various sensor models developed for linear pushbroom satellite images. We define the accuracy of a sensor model in two aspects: the accuracy of bundle adjustments and the accuracy of estimating exterior orientation parameters. The first accuracy has been analyzed and reported frequently whereas the second accuracy has somewhat been neglected. We argue that the second accuracy is as important as the first one. The second accuracy describes a model's ability to predict satellite orbit and attitude, which has many direct and indirect applications. Analysis was carried out on the traditional collinearity-based sensor models and orbit-based sensor models. Collinearity-based models were originally developed for aerial photos and modified for linear pushbroom-type satellite images. Orbit-based models have been used within satellite communities for satellite control and orbit determination. Models were tested with two Kompsat-1 EOC scenes and GPS-driven control points. Test results showed that orbit-based models produced better estimation of exterior orientation parameters while maintained comparable accuracy on bundle adjustments.

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

A study of the genomic estimated breeding value and accuracy using genotypes in Hanwoo steer (Korean cattle)

  • Eun Ho, Kim;Du Won, Sun;Ho Chan, Kang;Ji Yeong, Kim;Cheol Hyun, Myung;Doo Ho, Lee;Seung Hwan, Lee;Hyun Tae, Lim
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.681-691
    • /
    • 2021
  • The estimated breeding value (EBV) and accuracy of Hanwoo steer (Korean cattle) is an indicator that can predict the slaughter time in the future and carcass performance outcomes. Recently, studies using pedigrees and genotypes are being actively conducted to improve the accuracy of the EBV. In this study, the pedigree and genotype of 46 steers obtained from livestock farm A in Gyeongnam were used for a pedigree best linear unbiased prediction (PBLUP) and a genomic best linear unbiased prediction (GBLUP) to estimate and analyze the breeding value and accuracy of the carcass weight (CWT), eye muscle area (EMA), back-fat thickness (BFT), and marbling score (MS). PBLUP estimated the EBV and accuracy by constructing a numeric relationship matrix (NRM) from the 46 steers and reference population I (545,483 heads) with the pedigree and phenotype. GBLUP estimated genomic EBV (GEBV) and accuracy by constructing a genomic relationship matrix (GRM) from the 46 steers and reference population II (16,972 heads) with the genotype and phenotype. As a result, in the order of CWT, EMA, BFT, and MS, the accuracy levels of PBLUP were 0.531, 0.519, 0.524 and 0.530, while the accuracy outcomes of GBLUP were 0.799, 0.779, 0.768, and 0.810. The accuracy estimated by GBLUP was 50.1 - 53.1% higher than that estimated by PBLUP. GEBV estimated with the genotype is expected to show higher accuracy than the EBV calculated using only the pedigree and is thus expected to be used as basic data for genomic selection in the future.

Long-term Analysis of Availability and Accuracy Variation of GPS Ionospheric Delay Model (GPS 전리층 모델의 장기간 가용성 및 정확도 변화 분석)

  • Jeongrae Kim;Yongrae Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.841-848
    • /
    • 2023
  • The Klobuchar ionospheric model included in global positioning system (GPS) navigation messages provides ionospheric correction information to single-frequency users. This ionospheric model accuracy has a significant impact on the accuracy of navigation solutions. We examine the GPS navigation messages from 1993 to 2022 and analyze their accuracy, presence of coefficients and accuracy of the Klobuchar model. Early GPS navigation messages often did not include ionospheric data, and even when they did include ionospheric models, the accuracy was often quite low. From 2002, when the accuracy of the ionospheric model was stabilized, until 2022, the accuracy of the ionospheric model is analyzed by comparing it with the ionospheric model of the International GNSS Service (IGS). Changes in accuracy per day and per year and accuracy differences along geomagnetic latitude are analyzed.

Development of Effective Test Method for Positioning Accuracy of Armed Vehicle Inertial Navigation System (기동화력장비 관성항법장치의 효과적인 위치정확도 시험방법 개발)

  • Kim, Sung Hoon;Bae, In Hwa;Kim, Sang Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.4
    • /
    • pp.619-632
    • /
    • 2023
  • Purpose: The main function of INS (Inertial Navigation System) is to measure the position of an armed vehicle and its performance is confirmed through the positioning accuracy test of Korean Defense Standards (KDS). The current standards, however, do not provide clear test methods and the conditions for performing positioning accuracy tests. Accordingly, the purpose of this study is to develop a new method for positioning accuracy test which would be effective. Methods: In this study, a new INS positioning accuracy test method is suggested based on the analysis of test data collected through a statistical experiment known as central composite design. For the positioning accuracy experiment of K105A1, a self-propelled artillery, two factors of driving velocity and driving distance are considered. Results: Based on the analysis of experimental data, a regression model for the positioning error is fitted and the positioning accuracy test of INS is so developed to maximize the positioning error. The standard proximity rate is used as an additional test criterion to evaluate the performance level of INS. Conclusion: The proposed new positioning accuracy test for INS has the advantage of finding the nonconforming items effectively. It is also expected to be utilized for the other similar INS positioning accuracy tests.

Determination of S.I.F. for Mixed Mode Crack and Development of Accuracy (혼합모드 균열의 응력확대계수 해석과 정도 개선에 대한 고찰)

  • Bae, Won-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.355-361
    • /
    • 2004
  • The finite element method were used to determine the stress intensity factor of cracked plate. The stress method, displacement method and J Integral are most popular finte element method. ANSYS proposed another a kind of displacement method. In this paper, it was examined that the accuracy and utility of the ANSYS method could believable to determine the stress intensity factors of centered inclined crack. Generally, inclined crack has two portion of stress intensity factors, tensile mode F1 and shear mode F2. For the purpose of increasing the accuracy of stress intensity factors, examined the effect of the numbers of nodes and elements, crack tip element size and number of partition of the crack tip vicinity. It was found that the method proposed by ANSYS is useful and has high accuracy. Accuracy of calculated stress intensity factors was increased by increase of the number of nodes and elements, and at the small size of crack tip elements can get more highly accuracy.

  • PDF

A Study on Measurement Accuracy of Theodolite System(III) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 3 m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(III) - 시준거리 3 m에서 기준자 거리에 따른 측정 정도)

  • Yoon Yong Sik;Lee Dong Ju;Yoon In Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.48-54
    • /
    • 2005
  • The theodolite system consists of two theodolites, a scale bar and a target bu. A measurement accuracy of theodolite system is affected by a measurement distance of each equipment. This study was performed fir measuring an accuracy when the distance from theodolite to scale bar was changed 2~ 6 m on two theodolites distance 3 a The results showed thai the measurement accuracy could be $\pm$0.021 mm when the distance from theodolite to target was 2,3 and 6 n Specially, it was found that the maximum measurement accuracy was 10.017mm on theodolite collimation distance 3m and the distance 4 m of the theodolite and scale bar.

Investigation of physical sensor models for orbit modeling

  • Kim, Tae-Jung
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.217-220
    • /
    • 2005
  • Currently, a number of control points are required in order to achieve accurate geolocation of satellite images. Control points can be generated from existing maps or surveying, or, preferably, from GPS measurements. The requirement of control points increase the cost of satellite mapping, let alone it makes the mapping over inaccessible areas troublesome. This paper investigates the possibilities of modeling an entire imaging strip with control points obtained from a small portion of the strip. We tested physical sensor models that were based on satellite orbit and attitude angles. It was anticipated that orbit modeling needed a sensor model with good accuracy of exterior orientation estimation, rather then the accuracy of bundle adjustment. We implemented sensor models with various parameter sets and checked their accuracy when applied to the scenes on the same orbital strip together with the bundle adjustment accuracy and the accuracy of estimated exterior orientation parameters. Results showed that although the models with good bundle adjustments accuracy did not always good orbit modeling and that the models with simple unknowns could be used for orbit modeling.

  • PDF