• Title/Summary/Keyword: Acoustic calibrator

Search Result 5, Processing Time 0.026 seconds

A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape (음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구)

  • Kim, Chayeong;Shin, Kumjae;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • This paper identifies the cause of the high frequency calibration limit of the acoustic chamber type calibrator for microphone calibration and presents a method to improve it. By using a commercial finite element analysis software, we analyzed the calibration frequency limit of the acoustic chamber type calibrator through eigen-frequency and frequency domain analysis. Based on this, we designed and fabricated an acoustic chamber type calibrator that can precisely calibrate within 1 dB from about 2 Hz to 6.4 kHz and verified its performance through experiments. The acoustic chamber type calibrator fabricated through this study has the advantage of being able to calibrate multiple microphones simultaneously in a wide frequency range, so it can be usefully used for simple calibration for multiple microphones.

Design of the broadband and compact phase-calibrator for array microphones (어레이 마이크로폰용 광대역 소형 위상교정기의 설계)

  • Ju, Hyeong-Sick;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1032-1035
    • /
    • 2004
  • Pressure distribution is measured by way microphones to identify noise sources in the space. For example, beam-forming method or acoustic holography use phase information to identify the source. Therefore, the phase is significant information to correctly identify the source position. However, due to the microphone characteristics and measuring systems, measured signals always have errors, which make the identification difficult. Therefore, phase calibration of microphones is needed. Duct and speaker systems are generally used as calibrators. Acoustic characteristics of the calibrator are, of course, functions of many Parameters of the system: i.e. duct size, frequency, and microphone spacing. In this paper, design parameters which effect on the performance and size of the calibrators are considered. Then the parameters would be applied to design and real product of the phase-calibrator.

  • PDF

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS에서 수행된 음향관련 교정 및 시험 동향)

  • 서재갑;권휴상;정성수;조문재;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

APMP (Asia Pacific Metrology Programme) Regional Intercomparison Results of Acoustic Calibrators (음향교정기의 아시아.태평양 지역 국제비교 결과)

  • 서상준;서재갑;조문재
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.463-471
    • /
    • 2003
  • The results of the APMP (Asia Pacific Metrology Programme) regional intercomparison of acoustic calibrators were reviewed and analyzed. The artefacts used in intercomparison are a sound level calibrator and a pistonphone. The microphones used to measure the output pressure level are 1" and 1/2" standard microphones (LS1P, LS2P) as well as 1" and 1/2" reference microphones (WS1P/F, WS2P/F). The results obtained using standard microphones are satisfactory, but those obtained by the reference microphones, even though E/sub n/ values are within ±1.0, showed great deviations. Such results had come from the inaccurate calibration of reference microphones. By using the correct calibration results which were obtained by the recently established international standards, the new results were very similar to those of the foreign standard institutes.

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS 에서 수행된 음향관련 교정 및 시험 검사 동향)

  • Suh, Jae-Gap;Jung, Sung-Soo;Jho, Moon-Jae;Suh, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1767-1771
    • /
    • 2000
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 1999. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF