• Title/Summary/Keyword: Aging Diagnosis

Search Result 342, Processing Time 0.025 seconds

A Conceptual Framework for Aging Diagnosis Using IoT Devices (IoT 디바이스 기반 노화진단을 위한 개념적 프레임워크)

  • Lee, Jae Yoo;Park, Jin Cheul;Kim, Soo Dong
    • Journal of KIISE
    • /
    • v.42 no.12
    • /
    • pp.1575-1583
    • /
    • 2015
  • With the emergence of Internet-of-Things (IoT) computing, it has become possible to acquire users' health-related contexts from various IoT devices and to diagnose their biological aging through analysis of the IoT health contexts. However, previous work on methods of aging diagnosis used a fixed list of aging diagnosis factors, making it difficult to handle the variability of users' IoT health contexts and to dynamically adapt the addition and deletion of aging diagnosis factors. This paper proposes a design and methods for a dynamically adaptable aging diagnosis framework that acquires a set of IoT health contexts from various IoT devices based on a set of aging diagnosis factors of the user. By using the proposed aging diagnosis framework, aging diagnosis methods can be applied without considering the variability of IoT health contexts and aging diagnosis factors can be dynamically added and deleted.

Development of Aging Diagnosis Algorithm for Photovoltaic Modules by Considering Electric Characteristics and Environment Factors (전기적특성과 환경인자를 고려한 태양광모듈의 열화진단 알고리즘 개발)

  • Lee, Kye-Ho;Choi, Sung-Sik;Kim, Byung-Ki;Jung, Jong-Yun;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1411-1417
    • /
    • 2015
  • The installation of PV system to the power distribution system is being increased as one of solutions for environmental pollution and energy crisis. However, the efficiency of PV system is getting decreased because of the aging phenomenon and several operation obstacles. Therefore, The technology development of aging diagnosis of PV modules are required in order to improve operation performance of PV modules. This paper proposes evaluation algorithm for aging state in PV modules by using the electrical characteristics of PV modules and environmental factors. And also, this paper presents a operation evaluation system of PV modules based on the proposed aging diagnosis algorithm of PV modules. From the simulation results of proposed evaluation system, it is confirmed that the proposed algorithm is a useful tool for aging diagnosis of PV systems.

A Study on Pattern Making of Degradation Type Using K-means (K-means를 이용한 열화 형태의 패턴화에 관한 연구)

  • Lee, Deok-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.12
    • /
    • pp.877-882
    • /
    • 2014
  • It has been confirmed that the inner defect of transformer and the perfect diagnosis for aging are closely related to safe electric power transmission system and that the detection of accident and diagnosis technique turn out to be very important issues. Since electric power machinery consists of various kinds of components, however, it is very difficult to make a diagnosis for aging by one parameter. Thus, diagnosis for aging is feasible only through the combination of various parameters. Recently, various expert systems have been developed and applied to diagnosis for aging, but they are not yet reliable enough to apply to the real system. In this paper, XLPE which is ultra high voltage cable insulator material were chosen to investigate the influence of void on insulator material using partial discharge. Obtained data have been processed by PRPD (phased resolved partial discharge) distribution function and K-means. And statistical and cluster distribution of partial discharge have been analysed and investigated.

Normalization Diagnosis of Aging Process on Partial Discharge Signals of CV Cable (CV케이블의 부분방전 신호를 통한 열화과정의 정량적 진단)

  • 소순열;임장섭;김진사;이준웅;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.451-455
    • /
    • 1997
  • The partial discharge has been blown as the chief breakdown of power equipments. The analysis and the recognition is much difficult because the partial discharge signal is very small and has complex aging pattern. Recently, insulation aging diagnosis based on pattern of phase(Ф), partial discharge magnitude(q), number(n) has been very important. Owing to depreciate the reappearance of aging progress at the electrical tree pattern and to be difficult to analyze visually, the study on partial discharge pattern is suggested to normalizing analysis method of partial discharge signals. This parer is purposed on prediction of life-time measurement of cv-cable, on decision of risk degree with normalization and real-time measurement of partial discharge signals for aging diagnosis of cv-cable. As normalizing the aging signals of electrical tree in cv-cable, it is able to confirm risk degree of insulation material with the distribution of Ф-q-n and recognize the process of aging pattern using neural network.

  • PDF

Diagnosis method of DC/DC converter aging based on parasitic resister (기생저항변화를 고려한 DC/DC 컨버터 열화진단)

  • Kim T.J.;Baek J.W.;Lee B.K.;Ryu M.H.;Kim C.U.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.97-101
    • /
    • 2003
  • In this paper, we propose a new diagnosis method of DC/UC converter aging. The method is based on parasitic resister change with aging process. we apply to on-line diagnosis of DC/DC converter because of observing not a device but a system. We present the mathematical analysis and experimental study.

  • PDF

Design Methodology of Expert System for aging diagnosis of Arrester (피뢰설비 열화진단 전문가 시스템의 설계 방법론)

  • Kim, Tai-Jin;Rhyu, Keel-Soo;Kil, Gyung-Suk;Seong, Chang-Gyu;Kim, Il-Kwon;Park, Jong-Il;Weon, La-Kyoung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.69-70
    • /
    • 2006
  • The arrester's condition is related directly to protected equipment's safety. The most important is, therefore, arrester aging diagnosis. In this study, arrester aging diagnosis expert system is implemented to use JESS shell-engine and the leakage current detection technique.

  • PDF

Fault Diagnosis System for Traction Motor in Electric Multiple Unit (전동차 견인전동기 고장진단시스템)

  • Park, Hyun-June;Jang, Dong-Uk;Lee, Gil-Hun;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.518-521
    • /
    • 2003
  • A new measurement system was developed by fault diagnosis system for traction motor using current signal analysis. The motor current signature analysis method is used for traction motor fault diagnosis. The diagnosis system program is constructed by artificial neural networks algorithm, those results from the program are used to train neural networks. The trained neural networks have the ability to compute adaptive results for non-trained inputs, and to calculate very fast due to original parallel structure of neural networks with high accuracy within destined tolerance. This system suggested that available test for checking, the probable extent of aging, and the rate of which aging is taking place.

  • PDF

A Operating Status Diagnosis of DC/DC Converter by System Identification (System Identification Method를 이용한 DC/DC 컨버터 상태진단)

  • Kim, Cheul-U;Kim, Tae-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.724-729
    • /
    • 2007
  • In this paper, we propose a new diagnosis method of DC/DC converter aging. The method is based on variations of the parasitic resistor for the aging process. We apply an on-line diagnosis of the DC/DC converter because the observation is not a device, but a system. This study proposes a method of DC/DC converter diagnosis by analyzing the variations of model on the variations of parasitic resistor.

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION (열화 진단 평가를 위한 직류 누설법의 활용)

  • Lee, Kwan-Woo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

Power Transformer Diagnosis Using a Modified Self Organizing Map

  • Lee J. P.;Ji P. S.;Lim J. Y.;Kim S. S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Substation facilities have become extremely large and complex parts of electric power systems. The development of condition monitoring and diagnosis techniques has been a very significant factor in the improvement of substation transformer security. This paper presents a method to analyze the cause, the degree, and the aging process power transformers by the Self Organizing Map (SOM) method. Dissolved gas data were non-linearly transformed by the sigmoid function in SOM that works much the same way as the human decision making process. The potential for failure and the degree of aging of normal transformers are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.