• Title/Summary/Keyword: Air Amplifier

Search Result 40, Processing Time 0.024 seconds

Evaluation of Liquid Pressure Amplifier Technology

  • Reindl Douglas T.;Hong Hiki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.119-127
    • /
    • 2005
  • Liquid pressure amplifiers have been proposed as an energy saving technology for vapor compression refrigeration systems configured with direct-expansion evaporators. The technology utilizes a refrigerant pump in the high pressure liquid line as a means of maintaining a suitable pressure differential across the expansion valve while lowering condensing pressure to achieve the reduction of compressor energy consumption. Applications have been proposed on systems ranging from small unitary air-conditioning to large supermarket and commercial refrigeration systems. This paper clarifies the role of such a device in a vapor compression refrigeration system. Limitations are presented and discussed. Finally, results of detailed analyses are presented to quantify the energy consumption both with and without a liquid pressure amplifier in a unitary air conditioning system. The estimated energy savings associated with the installation of a liquid pressure amplifier are minimal.

Flow Characteristics of Mass Flow Amplifier with Various Geometrical Configurations (질량유량 증폭기 형상변화에 따른 유동 특성 연구)

  • Lee, Jeong-Min;Kang, Hyun-Su;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.36-42
    • /
    • 2016
  • Mass flow amplifier, which is an aerodynamic device, makes air flow increased by ejecting small amount of compressed air with $Coand{\breve{a}}$ effect. In this study, the flow characteristics of a mass flow amplifier were studied with various flow conditions and geometrical configurations. In order to improve the performance of mass flow amplifier, various values of clearance, diffuser angle and the aspect ratio of induced flow inlet to outlet were considered as design parameter. Furthermore, four different pressure conditions of compressed air were also considered. Numerical study was performed using the commercial CFD code, ANSYS CFX 14.5 with shear stress transport(SST) turbulent model. The results of pressure and velocity distributions were graphically depicted with different geometrical configurations and operating conditions.

Design and Realization UHF Power Amplifier for Air Traffic Control (항공교통관제용 UHF대역 전력 증폭기 설계 및 구현)

  • Kang, Suk-Youb;Song, Byoung-Jin;Park, Wook-Ki;Go, Min-Ho;Park, Hyo-Dal
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.167-172
    • /
    • 2006
  • In this paper, the 25W power amplifier for UHF band radio transceiver has been designed and realized. The power amplifier was composed of drive, power amplifier and control stages. Feedback topology and coaxial line baluns were used for wide band operation. The VDMOS, which has reliable performance for linearity and efficiency, was used for power device and designed to operate as push-pull amplification at Class AB Bias. The power amplifier designed in such a way was found to show stable AM modulation performance when voice signal was detected at the gate stage, with being designed and realized to meet output specifications of commercial air traffic control transmitter.

  • PDF

Transient Analysis of Five-Layer System Laser Amplifier (오층구조 레이저 증폭기의 과도현상론적해석)

  • 김영권
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.4
    • /
    • pp.16-24
    • /
    • 1966
  • The LASER Amplifier is treated in the manner of a Fabry-Perot Resonator with an active media, five layers are considered: air, reflector, active medium(ruby), reflector and air. One dimensional scalar wave equations are derived using the method of boundary value probrems in which it is assumed that incident coherent radiation falls normally on the surface wall. All equations are treated from the transient analysis point of view using the Laplace transform nethods, and are arranged steady state region as an amplifier and transient region as a self excited oscillator. Also some remarks are given on the design problem of LASER amplifier in connection with the transient terms involved.

  • PDF

Design of High-efficiency Power Amplifier System for High-directional Speaker (고지향성 스피커를 위한 새로운 전력 증폭기 설계)

  • Kim, Jin-Young;Kim, In-Dong;Moon, Wonkyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1215-1221
    • /
    • 2017
  • Parametric array transducers are used for highly directional speaker in an air environments. Piezoelectric micromachined ultrasonic transducers for parametric array transducers need DC-biased voltage driving signals in order to get high-directional quality-sound features. The existing power amplifier such as class A amplifiers has low efficiency and require large volume heatsinks. To overcome the above-mentioned disadvantages of the conventional amplifier, this paper proposes a new power amplifier system. The proposed power amplifier system ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier. Furthermore, the proposed power amplifier system gets high efficiency because it contains the DC-DC converter-type power supply which can perform energy recovery and envelope tracking function. Also the paper suggests the detailed circuit topology. Its characteristics are verified by the detailed experimental results.

Air Density Measurement in a Narrow Test Section Using a Laser Absorption Spectroscopy (레이저 흡수 분광법을 사용한 좁은 시험 구간 내 공기 밀도 측정)

  • Shim, Hanseul;Jung, Sion;Kim, Gyeongrok;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.11
    • /
    • pp.893-900
    • /
    • 2021
  • In this study, air density in a narrow test section is measured using a laser absorption spectroscopy system that detects oxygen absorption lines. An absorption line pair at 13156.28 and 13156.62 cm-1 are detected. A gas chamber with a height of 40 mm is used as a narrow test section. A triangular spiral-shaped laser path is applied in the gas chamber to amplify absorption strength by extending laser beam path length. A well-known logarithm amplifier and a secondary amplifier are used to electrically amplify absorption signal. An AC-coupling is applied after the logarithm amplifier for signal saturation prevention and noise suppression. Procedure of calculating spectral absorbance from output signal is introduced considering the logarithm amplifier circuit configuration. Air density is determined by fitting the theoretically calculated spectral absorbance to the measured spectral absorbance. Test conditions with room temperature and a pressure range of 10~100 kPa are made in a gas chamber using a Bourdon pressure gauge. It is confirmed that air density in a narrow test section can be measured within a 16 % error through absorption signal amplification using a triangular spiral-shaped beam path and a logarithm amplifier.

High Efficiency Fuel Cell System with Air Amplifier using Waste Heat (배열이용 공기증폭기를 활용한 고효율 연료전지 시스템)

  • Jun, Jaeho;Choi, Youngjae;Jun, Joonghwan;Kim, Seontae;Kim, Seongwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.72.1-72.1
    • /
    • 2010
  • 지금까지 연료전지 시스템의 효율을 극대화시키기 위한 기술들이 개발되어 왔는데, 대표적인 방법은 CHP(Combined Heat & power)와 FCT(Fuel cell & Turbine) Hybrid 시스템이다. 그러나 본 연구의 기술은 연료전지 배열을 이용한 Coanda 공기증폭기를 장착한 새로운 개념의 고효율 연료전지 시스템이다. 원래 공기 증폭기는 완만한 곡면 주위를 흐르는 유체가 곡면의 표면을 따라 흐름의 방향이 바뀌는 원리(Coanda Effect)를 이용한 장치로서, 소량의 고압유체를 구동 에너지원으로 사용하여 최고 20배에 해당하는 많은 양의 주변 유체를 빠른 속도로 이송시키는 역할을 한다. 문제는 고압의 유체원을 만드는 것인데, 본 연구에서는 발전용 연료전지 시스템의 배기가스를 활용하여 먼저 고압의 수증기를 발생시키고, 다음으로 고압의 수증기를 공기 증폭기의 구동원으로 사용함으로써 연료전지 시스템의 Air blower를 대체하는 것이다. 이러한 개념을 검증하기 위해서 고압의 스팀작동 Coanda 공기증폭기를 제작하여 선행실험을 진행하였다. 먼저 공기증폭기의 Gap 및 스팀압력에 따른 공기유량, 압력 등의 기본특성을 조사하였고, 출력 공기의 특성을 개선하기 공기증폭기의 형상 및 재료를 새롭게 설계하였다. 그리고 실제 시스템의 적용가능성을 알아보기 위해서, 예로 300kW급 용융탄산염 연료전지 발전시스템의 Air blower 대체가능성을 확인하였고, 배열이용 Coanda 공기증폭기를 활용한 고효율 연료전지 시스템의 개념설계를 수립하였다. 결론적으로 본 기술을 활용하면 연료전지 시스템의 최종 전기효율을 향상시킬 뿐 아니라는 시스템의 장기 신뢰성을 증대시키는 효과를 기대할 수 있다.

  • PDF

Design of Fuel Cell Power Generation System Using a Waste Heat (배열을 이용한 연료전지 발전시스템 설계)

  • Choi, Young-Jae;Jun, Jae-Ho;Jun, Joong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.133-133
    • /
    • 2009
  • 연료전지는 연료의 화학적 에너지를 전기화학 반응을 통하여 직접 전기로 변환하기 때문에 에너지 전환효율이 높고 공해물질을 배출하지 않는 환경친화적인 고효율 발전방식으로, 특히 용융탄산염 연료전지(MCFC) 및 고체산화물 연료전지(SOFC)같은 고온형 연료전지의 경우 분산전원이나 중앙집중발전 같은 발전용에 적합한 연료전지로 평가받고 있다. 현재 MCFC 및 SOFC등의 발전용 연료전지 시스템의 효율은 약 50% 정도이며, 시스템의 발전효율을 높이기 위한 여러 연구가 진행되고 있다. 그 중에서 고온의 배열을 이용하여 연료전지 발전시스템의 효율을 향상시키기 위해 FuelCell Energy, Ansaldo Fuel Cells 및 Simens Westinghouse 등에서 수백 kW급의 fuel cell - gas turbine hybrid system에 대한 상용화 수준의 실증연구가 진행되었다. 본 연구에서는 발전용 연료전지 시스템의 발전효율을 높이기 위한 방안 중 하나로 배열을 이용하여 steam을 발생시켜 air amplifier에 사용함으로써 연료전지 시스템의 MBOP(Mechanical Balance of Plant)중 전력을 소비하는 air blower를 대체하여, 시스템 효율을 향상시키고 시스템의 가용성을 높일 수 있는 설계안에 대하여 논하고자 한다.

  • PDF

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.