• 제목/요약/키워드: Air Curtain

검색결과 136건 처리시간 0.022초

지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구 (The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel)

  • 한방우;김학준;김용진;정상현;김용민;김종률
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

외부바람의 영향을 고려한 난방공간에서의 하향토출 에어커튼의 성능 (Performance of Downward-blowing Air Curtain m Heating Space Considering External Wind Condition)

  • 성순경
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.417-423
    • /
    • 2009
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. Design data for the air curtain given by previous researchers do not mention the influence of wind speed. Thus, this paper presents a performance of single jet air curtain in heating space when the wind blows toward the opening space of the building. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A new safety factor is also proposed for determination of air curtain jet velocity under the various wind conditions.

공조공간에서 수평토출형 에어커튼의 차단 성능 (Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

흡입관 주위에 형성된 공기차단막이 흡입성능에 미치는 영향 (Effect of the Suction Performance by the Air-Curtain Blowing around a Suction Duct)

  • 조종현;김재실;조수용
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.25-32
    • /
    • 2009
  • A study is conducted to improve the suction performance on suction devices which are used to remove polluted air generated by welding or machining process in a spacious working place of industry. Air-curtain is applied around the inlet of suction duct to interrupt the inflow of fresh air from the downstream region where is located opposite to the polluted air source. Two different air-curtain devices, such as a $45^{\circ}$ backward and a fully backward, are adopted. Suction region is experimentally investigated by measuring the suction velocities using a hot-wire anemometer. Contours of the suction velocity are compared with the computed results. The suction condition is selected to 110,000 Reynolds number which is widely used on typical suction devices, and a width of blowing passage for creating the air-curtain is chosen to 9.38% of the suction duct diameter. The experimental results show that the suction performance obtained with the $45^{\circ}$ backward air-curtain was better than that obtained with the fully backward air-curtain. On the suction duct using the $45^{\circ}$ backward air-curtain, the suction region estimated on basis of the 0.4m/sec is improved by 66% at the same input power.

조리대에 급기구를 가진 주방 레인지후드의 배기 성능 (Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table)

  • 성순경
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.

에어커튼형 주방 레인지후드의 배기 특성 (Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구 (A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

압축공기에 의한 수중 기포막의 특성 (Characteristics of Underwater Air-Bubble Curtain Generating by the Compressed Air)

  • 김재오
    • 수산해양기술연구
    • /
    • 제32권4호
    • /
    • pp.381-385
    • /
    • 1996
  • 압축공기에 의한 기포막을 어구로 활용하기 위한 기초 자료를 제공하고져 압축공익의 세기별, 기포 발생 호스 구명의 크기별, 간격별 기포막의 특성과 기포 소음의 음향학적 특성을 실험, 분석한 결과는 다음과 같다. 1. 공기 압축기(290l/min$\times$1.5Kw)와 용량 10kgf/$cm^2$인 공기 탱크로 구성한 기포막 발생 장치로써 발생시킨 기포막은 송기압이 0.2kgf/$cm^2$이상이 되어야 형성되고, 구멍의 크기보다는 구멍 간격이 넓어짐에 따라 더욱 높게 형성됨을 알 수 있었다. 2. 기포 발생시 음압은 구멍이 크고 간격이 조밀하며 기포막에 가까울수록 크며 기포 중심부의 주파수 변동폭은 구명이 적고 간격이 조밀할수록 높았다. 3. 기포막의 빔 각도는 유속에 비례하여 커지며, 유속이 0.1m/sec당 $10^{\circ}$씩 변화되었다. 4. 송기압을 0.5, 1.0, 1.5kgf/cm super (2)로 변화시키면서 기포 발생 호스를 수직방향으로 $0^{\circ}$, $10^{\circ}$, $20^{\circ}$로 각각 경사시켜 측정한 결과 기포막 수평길이는 기포막 발생 호스의 경사각도에 따라 그 길이를 최대 45% 연장 할 수 있었다.

  • PDF