• Title/Summary/Keyword: Air Injection

Search Result 1,198, Processing Time 0.025 seconds

Stabilization of Solid Waste in Lysimeter by Air Injection Mode (공기주입 방식을 이용한 매립모형조내 폐기물 안정화)

  • Kim, Kyung;Park, Joon-Seok;Lee, Hwan;Lee, Cheol-Hyo;Kim, Joung-Dae
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2005
  • This study was conducted to evaluate air injection mode on stabilization of solid waste in lysimeter. For three lysimeters, one was maintained under anaerobic condition as control, and air was injected into two lysimeters in continuous mode (atmospheric pressure) and intermittent mode (high pressure of 2 bar). Distilled water was sprayed over solid waste in 1.4 l/$m^3$(solid waste)/day, supposing rainfall intensity of 1,200 mm/yr and 30% infiltration. Oxygen in landfill gas was not detected in control lysimeter during operational days. After 30 day-aeration, oxygen concentrations of continuous and intermittent modes were maintained in 14% and 6%, respectively. $COD_{Cr}$ removal efficiencies of continuous and intermittent modes were about 70% and 50%, and BOD5 removal efficiencies were about 80% and 20%, respectively. In view of oxygen supply, and $COD_{Cr}$ and $BOD_5$ removal, continuous air injection mode of atmospheric pressure was more effective than intermittent mode of 2 bar. Settling degree of solid waste in case of two air injection modes was 3 times higher than that of anaerobic condition as control. Considering the above results, it was thought that air injection (especially continuous atmospheric pressure) could improve degradation of solid waste and induce preliminary stabilization in landfill site.

Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test

  • Lee, Mi Hyeon;Han, Cheol Sig;Lee, Sang Hoon;Lee, Jeong Hyun;Choi, Eun Mi;Choi, Young Ryong;Chung, Mi Hwa
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.286-290
    • /
    • 2013
  • Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours.

Flow Control of a Solenoid Gas Injector and Its Application on a Natural Gas Engine (솔레노이드 가스 인젝터의 유량제어와 천연가스엔진에서의 응용)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.83-89
    • /
    • 2009
  • An air-fuel ratio control is essential in reducing hazardous exhaust emissions from a compressed natural gas(CNG) engine, and can be accomplished by accurate control of gas injection flow. In this study, theoretical research was conducted on injection characteristics of a solenoid gas injector, and injection experiments for calibration and analysis were performed. Various factors for gas injection flow such as injection pressure, gas temperature, and supply voltage are studied. A dynamic flow equation of the natural gas was proposed on the basis of flow dynamics theories and results of the injection experiment. The verification of the dynamic flow equation of the solenoid injector was carried out with a large CNG-engine applied to an urban bus. Air-fuel ratio control experiments were conducted in both steady and transient state. Results of injection experiments for the solenoid injector and the CNG-engine was proved the control method proposed herein to be effective.

  • PDF

Spray Characteristics of Air-assisted Vortex Nozzle at Low Pressure Condition (공기보조식 와류 노즐의 저압 분무특성)

  • Kim, Woojin;Subedi, Bimal;Choi, Jang-Soo
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.82-87
    • /
    • 2015
  • A nozzle with vortex generator was used to develop the low pressure nozzle with high atomization performance and the nozzle atomized the liquid by centrifugal shear forces. In order to analyze the atomization characteristics, a shadowgraphy method was used and the measurement of droplet size was performed by using laser diffraction analyzer. The liquid injection pressure was fixed as 0.03 bar which is very low pressure and the gas injection pressures were changed from 0 bar to 2.0 bar. As a result, the breakup was achieved at the air injection pressure of 0.25 bar and over. The nozzle with the orifice diameter of 0.4 mm and the orifice gap of 0.25 mm presented small droplet diameters under 50 at the air injection pressure of 0.75 bar.

A Development of Environmental-friendly Burner with High Injection Velocity by Multi-staged Fuel-injection (환경친화형 연료분할-고속분사식 버너 개발)

  • Choo, Jae-Min;Ko, Young-Ki;Kim, Jong-Woo;Kim, Cheol-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.148-155
    • /
    • 2005
  • In this study, Development of 300,000kcal/hr high velocity Injection burner with fuel multi-stage was performed using experiments. The characteristics of NOx emission in multi fuel/air staged combustor have been experimentally studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is largest access air combustion and the secondary flame is complete combustion zone, where most of fuel bums. Experiments were performed on an industrial scale in a laboratory furnace and Liquefied Natural Gas(LNG) was used as primary and secondary fuels. Comparison of outlet NOx and outlet Temperature under various air rate and primary/ secondary fuel ratio was performed. The test demonstrated that NOx emission con be reduced by 70% in accordance with operating conditions.

  • PDF

Removal Effect of malodorous Substances of Piggery Wastes by Air Injection Method (공기주입에 따른 양돈분뇨중 악취제거 특성 연구)

  • 고현준;김명중;신경섭;양진모;이명규
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.115-123
    • /
    • 1997
  • This study was conducted to investigate the removal effect of malodorous substances of piggery wastes by air injection. With 7% of TS weight of artificial piggery wastes, this study focused on the changes of the concentration of VFAs, H2S during treatment period of 14 days. As a results of this study, air injection volume for removal of malodorants in this study was 150$m\ell$ / min$.$l$.$Under this condition, we found the concentrations of VFAs, H2S, NH3 have very high relationship with the pH, ORP, BOD, {{{{ { NH}`_{4 } ^{+ } }}-N. Especially, the concentration of Volatile Fatty Acids, one of most offensive odorants and one of BOD compounds were depended on ORP which can be controled by air injection in artificial piggery wastes.

Combustion Characteristics of Flameless Combustion by Reactants Injection Conditions (반응물 분사조건에 따른 무화염 연소특성 연구)

  • Hong, Seong Weon;Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.8-16
    • /
    • 2013
  • The flameless combustion has been considered as one of the promising combustion technology for high thermal efficiency, reducing NOx and CO emissions. In this paper, the effect of air and fuel injection condition on formation of flameless combustion was analyzed using three dimensional numerical simulation. The results show that the high temperature region and the average temperature was decreased due to increase of recirculation ratio when air velocity is increased. The average temperature was also affected by entrainment length. Generally mixing effect was enhanced at low entrainment length and dilution was dominated at high entrainment length. This entrainment length was greatly affected by air and fuel injection velocity and distance between air and fuel. It is also found that the recirculation ratio and dilution effect were generally increased by entrainment length and the recirculation ratio, mixing and dilution effect are the significant factor for design of flameless combustion system.

A Study on the Spray and Combustion Characteristics of Gasoline Direct Injector (가솔린 직분식 인젝터의 분무 및 연소특성에 관한 연구)

  • 신민규;박종호;유철호;이내현;최규훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.114-122
    • /
    • 1997
  • Nowadays, gasoline direct injection engines are being commercialized by virtue of improvement in control technology of spray, flow, air fuel ratio. The stratified charge type has the advantage of improving lean limit. The homogeneous type has the advantage of reducing engine-out hydrocabon emissions in the first 30 seconds after a cold start, in addition, improving transient air fuel ratio control. The vaporization and mixing if injected fuel with air has to e completed in a short time and the fuel film in cylinder and on piston has to be minimized. So, the flow and injection should be well controlled. This paper surveyed the spray characteristics of gasoline direct injection by using laser equipment and the combustion characteristics of the single cylinder engine using homogeneousas-mixture type gasoline direct injection.

  • PDF

Effect of Secondary Air Injection on CO and NOx Emission in an Internally Circulating Fluidized Bed Combustor (이중 순환식 유동층 연소로내에서 2차 공기 주입에 의한 CO, NOx 저감효과)

  • Jang, S.D.;Shin, D.H.;Hwang, J.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.204-211
    • /
    • 2002
  • Combustion experiments are carried out to obtain the fundamental data for application of a internally circulating fluidized bed combustor to the combustion of paper sludge wastes. Experimental parameters are identified as secondary air ratio, sludge weight and water contents. The secondary air ratio was varied from 0 to 20% and water content was 14%, 25%, 35%, 45%, 62% and sludge weight was 30g, 60g, 90g. As a result, carbon conversion ratio was higher than injection of primary air. Emission of CO and NOx reduced with an increase of secondary air injection.

  • PDF