• Title/Summary/Keyword: Air quality issues

Search Result 120, Processing Time 0.033 seconds

Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning (저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해)

  • Jo, Wan Geun;Gwon, Gi Dong;Choe, Sang Jun;Song, Dong Ik
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

A Comparative Study of Measuring Air Liners′ Service Quality (항공사 서비스 품질 측정방법의 비교 연구)

  • 장대성
    • Journal of Korean Society for Quality Management
    • /
    • v.31 no.4
    • /
    • pp.36-54
    • /
    • 2003
  • There have been academic debates upon which measure is more desirable in measuring service qualify between SERVQUAL and SERVPERF. In addition, Korean air lines industry is rapidly growing due to the increase of Koren family income and globalization. This study tried to contribute to both academic and practical issues. This study compared SERVQUAL and SERVPERF measures to determine which is superior to measure service quality in Korean air lines industry. Data was collected from two airliners' customers of Korea. According to the results of confirmatory factor analyses, regression analyses and analyses of goodness of fit, SERVPERF appears to be better in measuring service quality in Korean air lines industry than SERVQUAL. We suggest that SERVPERF be used to measure service quality in Korean air lines industry.

Indoor Air Quality in Aircraft: The Impact of Increased Mobility and Health Effects and the Influence of Bleed Air (항공기 내 실내공기질에 관한 고찰: 이동의 증가와 건강에 미치는 영향 및 블리드에어의 영향)

  • Seunghon Ham
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.129-133
    • /
    • 2023
  • Background: With the rise in global mobility, aircraft indoor air quality has become a significant public health concern. This study focuses on the health implications of increased travel and bleed air-air drawn from aircraft engines for cabin pressurization and air conditioning. Objectives: This research aims to review the potential health effects related to exposure to aircraft cabin air, particularly the effects of bleed air during fume events. Methods: We conducted a literature review of existing studies on aircraft cabin air quality. We focused on both the immediate and health effects of exposure to cabin air, particularly those related to bleed air contaminants. Results: The review found a possible link between exposure to aircraft cabin air and certain health issues, especially in cabin crew and frequent flyers. There was an increased incidence of respiratory and neurological symptoms related to bleed air exposure. However, the cumulative health effects of frequent air travel remain inconclusive due to limited data. Conclusions: This study highlights the need for improving air quality in aircraft to protect public health. While further research is needed to understand the cumulative effects of frequent air travel, the reduction of exposure to bleed air contaminants should be a priority. These findings underline the need for regulatory changes and technological improvements in aircraft cabin air quality.

Photocatalytic Oxidation of Indoor Air Volatile Organic Compounds (VOCs) in pub Level

  • Jo, Wan-Kuen;Kim, Dong-Hyun;Ki, Jae-Chang;Huh, Jeung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E4
    • /
    • pp.157-168
    • /
    • 2003
  • This study evaluated the technical feasibility of the application of titanium oxide (TiO$_2$) photocatalysis for the removal of VOCs in low ppb concentrations commonly associated with non -occupational indoor air quality issues. A series of experiments were conducted to evaluate four parameters (relative humidity (RH), hydraulic diameter (HD), photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs presented significant dependency on the RH, which is inconsistent with a few previous studies. However, it is noted that the three parameters (HD, RM and IPS) should be considered for better VOCs removal efficiencies for the application of TiO$_2$ photocatalytic technology for cleansing non -occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO would be negligible in comparison to the indoor CO levels. These results can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Critical Evaluation of and Suggestions for a Comprehensive Project Based on the Special Act on Seoul Metropolitan Air Quality Improvement (수도권 대기환경 개선사업-진단과 제언)

  • Baek, Sung-Ok;Koo, Youn-Seo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2008
  • On January 1, 2005, the Korean Ministry of Environment put into operation a comprehensive program, so called 'Blue Sky 21' project, for the improvement of air quality in greater Seoul metropolitan area. This program was legally based on the 'Special Act on Metropolitan Air Quality Improvement' for Greater Seoul area, which was established in 2003, and should be updated every 10 years. The principal objective of this program is to improve the air quality in Seoul and surrounding area by 2014 to the levels of air quality in Tokyo and Paris, with particular emphases on reducing the concentrations of nitrogen dioxide and $PM_{10}$. Any regulation of the emission of toxic air pollutants in general, and $NO_2$ and $PM_{10}$ in particular, should be based on human exposure levels and consequential health effects. In this article, the contents and feasibility of the special program were critically evaluated with respect to the reduction of health risks. Important issues for improving not only air quality but public health are discussed, and future requirements for the success of the special program are suggested.

Assessment of Indoor Air Quality(IAQ), Comfort and Safety in Metro Subway Station

  • Choi, Gi-Heung
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • With ever increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants (mostly metro personnel) have become important social issues. Considering the fact that various physical variables and pollutants such as particulate, VOCs and biological agents are closely related to indoor air quality (IAQ) which may cause health problems, a method of quantitative assessment using information-theoretic measure on such variables needs to be devised and implemented for comfort, health and safety of passengers and occupants in the subway station. A basic framework for assessing indoor air quality (for comfort and health) and safety in subway station is suggested. In particular, application of information-theoretic measure for the assessment of indoor air quality, comfort and safety in subway station is discussed. Some examples are presented as well.

Key air pollution problems in the early 21st century

  • Brlmblecombe, Peter
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.5-10
    • /
    • 2003
  • This paper explores not only emerging scientific problems but also the difficulties communicating air quality issues into an increasingly sensitive the public and policy arena. The public understanding and trust in air pollution information and indices may be very different to the notions of validity or accuracy that are important for a scientist. We operate in a world where openness requires us to reveal both the difficulties and disagreements in our understanding of the polluted atmosphere. Yet this can be confusing and increase complexity in situations where clear political and social decisions are required. I am going to examine these issues, starting with questions of what substances we regard as pollutants and the difficulties of getting the correct balance of concern given the broadening the base of chemicals emitted to the environment. There are also questions of exposure particularly in terms of vulnerable populations, who may spend large amounts of time indoors, where air is rarely monitored. In contemporary society there are pollution problems that extend far beyond urban areas and we have to consider regional issues such as windblown dusts, smoke from forest fires along with issues of the emission of green house gases and ozone depleting substances. Finally I will discuss the issues of communicating with a concerned public and sceptical politicians and the troubling interface between technological and sociological control. Such complexity is often missed in a maze of seemingly stronger political and social needs.

  • PDF

Characteristic of indoor air quality according to ventilation in a temporary residential building

  • Chae, Ho-Byung;Nam, Yujin;Sung, Min-Ki;Kim, Jong-Hun
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.5-12
    • /
    • 2015
  • Recently, natural disasters have unexpectedly occurred at various places in the world and the countermeasure of them become the social issues. Many of victims in disasters need temporary residential facilities above all things and many of researches have been conducted in order to develop simple, safe, and economic designs of them. Moreover, indoor thermal comfort and air quality must be considered in the facilities against a disaster, because clean and healthy space should be provided to the suffered victims. In this research, in order to estimate the indoor environment of the developed modular building for disaster preparation, CFD simulation was conducted in the various condition. In this paper, indoor air quality such as the age of air, the concentration of $CO_2$ was estimated by the case study

Design and Development of GIS-based Air Quality Information System for Ubiquitous Public Access (Ubiquitous Public Access 구현을 위한 GIS 기반 대기환경 정보시스템 설계 및 개발)

  • Hong, Sungchul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.195-201
    • /
    • 2017
  • Urbanization and industrialization have led to a severe deterioration in urban air qualities. As an air pollution is closely associated with human health, citizen has a growing concern about the air quality policy to improve their residential environment. Due to the recently advance in web- and mobile computing technologies, citizens can easily access various air quality information and public authorities utilize the social media service to communicate citizens with air quality issues. Also citizens' participation and role has been increased to improve urban air qualities. Thus, to meet the technical and societal changes, a GIS-based air quality information system is developed based upon the Ubiquitous Public Access (UPA) model in ISO19154. The proposed system employs the context information model to provide air quality information depending on citizens' health conditions and locations. Also, citizens can present their perceptions of an air quality at their current location Public authorities can thus utilize the citizens' perceptions when establishing new air quality policies.

Indoor Air Condition Measurement and Regression Analysis System Through Sensor Measurement Device and Gated Recurrent Unit (센서 측정기와 회로형 순환 유닛(GRU)을 이용한 실내 공기 품질 측정 및 추세 예측 시스템)

  • Ahn, Jaehyun;Shin, Dongil;Kim, Kyuho;Yang, Jihoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.9
    • /
    • pp.457-464
    • /
    • 2017
  • Indoor air quality analysis is conducted to understand abnormal atmospheric phenomena and the external factor affecting indoor air quality. By recording indoor air quality measurements periodically, we are able to observe patterns in air quality. However, it difficult to predict the number of potential parameters, set parameters for a given observation and find the coefficients. Moreover, the results are time-dependent. Thus to address these issues, we introduce a microchip capable of periodically recording indoor air quality and a model that estimates atmospheric changes based on time series data.