• Title/Summary/Keyword: Air shroud

Search Result 39, Processing Time 0.041 seconds

Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer (열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정)

  • U, Dae-Seong;Go, Dae-Gwon;An, Su-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.86-94
    • /
    • 1987
  • In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60$^{\circ}$ ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90$^{\circ}$shroud valve was larger than that of 120$^{\circ}$shroud valve, and 90$^{\circ}$shroud valve at 180$^{\circ}$shroud position had the largest turbulent intensity.

  • PDF

Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer (열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정)

  • Dae-Sung Woo;Dae-Kwon Ko;Soo-Kil Ahn
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.40-40
    • /
    • 1987
  • In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60° ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90°shroud valve was larger than that of 120°shroud valve, and 90°shroud valve at 180°shroud position had the largest turbulent intensity.

The Spray Characteristics of Simplex Atomizer under Various Shroud Air Conditions with Swirl Flow (쉬라우드 공기의 선회 유동 특성 변화에 따른 심플렉스 연료 노즐의 분무 특성)

  • Lee, D.H.;Lee, K.Y.;Choi, S.M.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.35-41
    • /
    • 2004
  • The spray characteristics were investigated to study the effect of shroud air with swirl flow on simplex type fuel injector for gas turbine combustor. The spray tests using PDA(Phase Doppler Anemometry) technique were conducted to compare the performance of simplex atomizer with $0^{\circ},\;40^{\circ},\;50^{\circ}$ swirled-shroud air conditions. In this study. we found that the injector with strong swirled-shroud air has the better atomization Performance compared with weaker swirled and non-swirled conditions.

  • PDF

Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit (실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계)

  • Ryu, Ki-Jung;Kim, Yoo-Yil;Lee, Kwan-Soo;Cha, Woo-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

Study on Noise Reduction of an Air Conditioner through Modification of Axial Flow Fans and Shrouds (축류팬 및 슈라우드 개선을 통한 공조기 저소음화에 대한 연구)

  • Kim, Chang-Joon;Yoon, Hong-Yeol;Jung, Young-Gyu;Park, Young-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.380-387
    • /
    • 2000
  • In this paper, a successful result of modification of an axial flow fan and a shroud for noise reduction of a window type air conditioner is presented especially in order to verify the importance of blade shape improvement and the searching for the optimal shape of shrouds. Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have special shapes. From the viewpoint of the shape in a shroud, several cases were examined and the particular value of a design parameter of the shroud was acquired to get the best noise reduction of an air conditioner. Through the application of the methods, the air conditioner became less noisy by 4.5 dB(A) in terms of air-borne noise produced only by the axial flow fan and consumed less energy by 20.9% compared to the current one.

  • PDF

A study on distribution of drop size and injection rate of air-shroud injector sprays under steady and transient injection condition (정상.과도 분사 조건에서의 에어슈라우드 인젝터 분무의 입경.분사량 분포에 관한 연구)

  • Lee, C.H.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.17-23
    • /
    • 2004
  • Spray characteristics of a twin-hole air shrouded nonle designed for gasoline injectors was investigated by using laser diffraction particle analyzer (LDPA) and tomography reconstruction- A confined spray chamber which is optically accessible through a pair of glass windows was made to simulate the fuel injection condition in intake manifold of gasoline engine. The measurement was applied to the twin hole injector with and without an air shroud. It demonstrates that for the case with an air shroud, fine atomization is achieved and there exists a large number of fine droplets between the region of the main spray streams, which conforms with the spray visualization. The drop size distribution was investigated as a function of elapse time after fuel injection. The distribution was greatly affected by the measurement position from the injector exit. Also, the spatially resolved spray volume fraction and Sauter Mean Diameter (SMD) from line-of-sight data of the LDPA are tomographically reconstructed by Convolution Fourier transformation under the steady injection condition.

  • PDF

Optimization of design parameters on the shroud of air conditioner outdoor unit (실외기 shroud 형상 최적 설계)

  • Ryu, Ki-Jung;Ye, Huee-Youl;Lee, Sang-Bong;Lee, Kwan-Soo;Cha, Woo-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit as function of shroud design parameters. To determine the optimal design parameters, we investigated the flow rate by changing bell mouth height, fan height, fan guide height, fan width. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. The flow rate of the optimum model, compared to that of the base model, was increased by about 6.25%.

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (에어컨 실외기의 소음원 규명 및 소음저감)

  • 서상호;임금식;이내영;진심원
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1043-1052
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan. heat exchanger and shroud. First. the fluid noise is reduced through the design of new fan and shroud. reduction of the system resistance by rearrangement of heat exchanger. and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4∼5dB (A).

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (실외기 소음원 규명 및 소음저감)

  • 서상호;이근동;이내영;진심원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

Spray Behavior and Atomization Characteristics of Dual Stream Gasoline Injectors (2중 분류 가솔린 연료분사기들의 분무거동 및 미립화 특성)

  • Song, Bhum-Keun;Kim, Won-Tae;Kang, Shin-Jae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.112-120
    • /
    • 2005
  • The injector, which is used in a 4-valve gasoline engine, is required to be maintained the dual stream because of the design of dual intake port. In addition, the spray characteristics of fuel injector have strong influence on engine performance, exhaust emission, fuel consumption, and especially the cold start condition for the port injection. So, commercial gasoline injectors off different type were inspected. Those are 2 hole,4 hole, air shroud 4 hole, and air shroud 4 hole injector with separator. The spray behavior of dual stream was researched by the visualization system and PDPA system was employed to measure the droplet size. Atomization is one of the most important characteristic, so droplet size distributions and SMD are investigated. And the spray characteristics of each injector are also analyzed such as the spray tip penetration, spray angle, and separation angle.