• 제목/요약/키워드: Air sterilizer performance

검색결과 13건 처리시간 0.027초

공기정화 살균기 개발 및 성능검증 연구 (A Study on Development and Performance Test of an Air Purify-sterilizer)

  • 정재윤;장조원
    • 한국항공운항학회지
    • /
    • 제14권3호
    • /
    • pp.51-59
    • /
    • 2006
  • The air purity-sterilizer was developed and the CFD and experimental studies were carried out in order to investigate the performance of a air purity-sterilizer. Overhaul and exchange efficiency were increased by the modularization of the air purity-sterilizer. The good performance was validated by the hot-wire measurements and flow simulations in the room. Mean velocities at the exit of the air purity-sterilizer were 0.91, 1.62, 1.99, and 6.14 m/sec according to the fan mode. And the flow visualization of pured air was shown by using CFD flow simulation in the room of 24, 50 pyeong. The results show that the air purity-sterilizer has a high performance enough to produce air purity-sterilizer on a commercial scale.

  • PDF

미생물 안전을 위한 승용차 실내 UVGI 살균기 설치에 관한 시뮬레이션 연구 (A Study on simulation analysis of UVGI air sterilizer installation in a car for microbiological safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.279-287
    • /
    • 2014
  • The recent rise in SARS and bird flu infections around the world has raised the interest in studying the habits of air borne pathogens such as germs and viruses. In this study, simulations were carried out to predict the performance of UVGI air sterilizer at preventing airborne infections inside a car, based on the installation position and the removing effect of the UVGI air sterilizer. Simulation results showed that the UVGI air sterilizer was most effective when located at the rear side of the front seats. It was also showed that when the out-air mode and the UVGI air sterilizer were set to the highest capacity, the microbial safety levels were maintained in a car for 21 hours.

공기감염 전파방지를 위한 UVC 공기살균기 성능평가에 관한 연구 (The Study on the Performance Estimation of UVC Air Sterilizer for Preventing Transmission of Air Borne Contagion)

  • 최상곤;홍진관
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.581-586
    • /
    • 2005
  • Recently, the use of UVGI system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and indoor air sterilization effect of UV ray for preventing transimission of air borne contagion was investigated by using manufactured UVC air sterilizer. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature in irradiance performance test. An individual microbiological killing effectiveness experiment also shows that the average kill rate of two microbiological samples such as bacteria and fungus is about $92\%$ by using manufactured UVC air sterilizer. Additionally irradiance performance experimental results also show that the ballast is very important factor to keep up irradiance performance of UVC lamp.

건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구 (A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

개별공간의 자외선 살균 시스템 (UV Immune System of Personalized Space)

  • 정기범;최상곤
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구 (A Study of air Sterilization System in Personalized Office Using Simulation)

  • 최상곤
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

멀티존 시뮬레이션에 의한 공동주택의 미생물 오염원 확산과 제거에 관한 연구 (A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation)

  • 홍진관;최상곤
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.291-298
    • /
    • 2007
  • The purpose of this study is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs such as bacteria and fungus and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for immune building systems.

실내 미생물오염 전파방지를 위한 멀티죤 모델링에 관한 연구 (The study on the multizone modeling for preventing transmission of air borne contagion)

  • 최상곤;이현우;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.429-435
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 which is developed by NIST is used for modeling the air disinfection system which is consist of dilution, filtration, ultra violet germicidal irradiation (UVGI) for removing the indoor microorganism such as bacteria and fungus. Developed models those protect occupants against indoor microorganism generated in our daily life are enable to use for immune building simulation tool. Also, results indicate that those models are enable to compute the real situation that is almost impossible of carrying out experiment and identify the disinfection rate with highly reliance. Results also suggest that engineers will use these models as a design tool for the immune building system.

  • PDF

멀티죤 시뮬레이션에 의한 공동주택의 미생물 오염원제거 성능평가에 관한 연구 (The study on the Performance of air sterilization of multistoried apartment by the multizone modeling)

  • 최상곤;박경수;윤영수;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.319-324
    • /
    • 2006
  • The purpose of this study Is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for Immune building systems.

  • PDF

실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구 (A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion)

  • 최상곤;이현우;홍진관
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.