• Title/Summary/Keyword: Alarm Signals

Search Result 129, Processing Time 0.045 seconds

An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings (공동주택에서의 화재 경보음 전달특성에 관한 연구)

  • Lee, Min-Joo;Kim, Myung-Jun;Yoon, Myong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

Reduction of False Alarm Signals for PIR Sensor in Realistic Outdoor Surveillance

  • Hong, Sang Gi;Kim, Nae Soo;Kim, Whan Woo
    • ETRI Journal
    • /
    • v.35 no.1
    • /
    • pp.80-88
    • /
    • 2013
  • A passive infrared or pyroelectric infrared (PIR) sensor is mainly used to sense the existence of moving objects in an indoor environment. However, in an outdoor environment, there are often outbreaks of false alarms from environmental changes and other sources. Therefore, it is difficult to provide reliable detection outdoors. In this paper, two algorithms are proposed to reduce false alarms and provide trustworthy quality to surveillance systems. We gather PIR signals outdoors, analyze the collected data, and extract the target features defined as window energy and alarm duration. Using these features, we model target and false alarms, from which we propose two target decision algorithms: window energy detection and alarm duration detection. Simulation results using real PIR signals show the performance of the proposed algorithms.

An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings (공동주택 화재 경보음 전달특성과 개선방안 고찰)

  • Lee, Min-Joo;Yoon, Myong-O;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

A Study on the Application of Alarm Signals for the Realization of OAM Function in the WDM Optical Transmission System (WDM 광전송시스템의 감시제어 기능실현을 위한 경보신호 적용에 관한 연구)

  • Lee, Chang-Ki;Cha, Young-Wook
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.9
    • /
    • pp.2958-2968
    • /
    • 2000
  • To effectively supervise WDM systems requires that the alarm signals for each optical transport network layer is considered. The related recommendations and studies for alarm signals are defining fundamental functions without specifying the structure and configuration of the supervisory channel. In this paper, we propose the detailed alarm signals and propagation flows for each optical transport network layer. We also describe the structure of overhead and the configuration of supervisory channel. Our proposals are based on the ITU T requirements of optical transport network and the supervisory schemes of terminal & add-drop systems. We show that our proposed schemes effectively performs supervisory functions for various fault conditions which will occur in terminal & add-drop typed WDM systems.

  • PDF

Analysis of false alarm possibility using simulation of back-scattering signals from water masses (수괴 산란신호 모의를 통한 오탐 가능성 분석)

  • Ha, Yonghoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.2
    • /
    • pp.99-108
    • /
    • 2021
  • In this paper numerical wave propagation experiments have been performed to visually confirm whether the signals scattered by water masses can be a false alarm in active sonar. The numerical environments consist of exaggerated water masses as targets in free space. Using a pseudospectral time-domain model for irregular boundary, the back-scattered signals have been calculated and compared with analytic solutions. Also, the sound propagation was simulated. Consequently, it was verified that water masses themselves could not be detected as a false target.

Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings (공동주택 화재경보 발생음 특성에 관한 실험연구)

  • Lee, Min-Joo;Kang, Hee-Hyuk;Kwon, Bong-Suk;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System (디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

A Case Study of the Characteristics of Fire-Detection Signals of IoT-based Fire-Detection System (사례 분석을 통한 IoT 기반 화재탐지시스템의 화재 감지신호 특성)

  • Park, Seung Hwan;Kim, Doo Hyun;Kim, Sung Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.16-23
    • /
    • 2022
  • This study aims to provide a fundamental material for identifying fire and no-fire signals using the detection signal characteristics of IoT-based fire-detection systems. Unlike analog automatic fire-detection equipment, IoT-based fire-detection systems employ wireless digital communication and are connected to a server. If a detection signal exceeds a threshold value, the measured values are saved to a server within seconds. This study was conducted with the detection data saved from seven fire accidents that took place in traditional markets from 2020 to 2021, in addition to 233 fire alarm data that have been saved in the K institute from 2016 to 2020. The saved values demonstrated variable and continuous VC-Signals. Additionally, we discovered that the detection signals of two fire accidents in the K institution had a VC-Signal. In the 233 fire alarms that took place over the span of 5 years, 31% of smoke alarms and 30% of temperature alarms demonstrated a VC-Signal. Therefore, if we selectively recognize VC-Signals as fire signals, we can reduce about 70% of false alarms.

Effective Elimination of False Alarms by Variable Section Size in CFAR Algorithm (CFAR 적용시 섹션 크기 가변화를 이용한 오표적의 효율적 제거)

  • Roh, Ji-Eun;Choi, Beyung-Gwan;Lee, Hee-Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.100-105
    • /
    • 2011
  • Generally, because received signals from radar are very bulky, the data are divided into manageable size called section, and sections are distributed into several digital signal processors. And then, target detection algorithms are applied simultaneously in each processor. CFAR(Constant False Alarm Rate) algorithm, which is the most popular target detection algorithm, can estimate accurate threshold values to determine which signals are targets or noises within center-cut of section allocated to each processor. However, its estimation precision is diminished in section edge data because of insufficient surrounding data to be referred. Especially this edge problem of CFAR is too serious if we have many sections to be processed, because it causes many false alarms in most every section edges. This paper describes false alarm issues on MCA(Minimum Cell Average)-CFAR, and proposes a false alarm elimination method by changing section size alternatively. Real received data from multi-function radar were used to evaluate a proposed method, and we show that our method drastically decreases false alarms without missing real targets, and improves detection performance.