• Title/Summary/Keyword: Allowable Load

Search Result 506, Processing Time 0.03 seconds

Stacking Durability Analysis of Fruit , Packaging Boxes by Creep (크리이프에 의한 과실 포장입자의 층적 내구성 분석)

  • 박종민;권순홍;권순구;김만수
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.191-197
    • /
    • 1996
  • Allowable stacking duration of the corrugated fiberboard boxes being widely used for packaging fruits and vegetables was analyzed by the creep behavior and the cumulative load correction factor for the boxes. The stacking boxes were assumed to be stored at a nearly constant temperature and relative humidity condition. When the stacking duration was short period, the stacking height determined by two methods showed a little difference between them, but almost no difference was shown as the stacking duration was longer. Allowable stacking duration was rapidly decreased with the increase of static load applied on the stacking boxes, and allowable stacking duration of Box A was estimated the longer than that of Box B. A model of allowable stacking duration for the corrugated fiberboard box was developed as a function of the stacking load and the ambient relative humidity.

  • PDF

Evaluation on Structural Performance of Structural Insulated Panels in Wall Application (벽식 구조체 적용을 위한 구조용단열패널 성능 평가)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Lee, Cheol-Hee;Hwang, Sung-Wook;Jo, Hye-Jin;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.

Evaluation of Skin Friction Using Tensile Load Testing of CPR Piles (CPR 말뚝의 인발재하시험을 통한 주면마찰력 평가)

  • Ko, Chin-Surk;Kim, Jung-Han;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2020
  • Pull-out load tests were performed on a CPR (Compaction grouting compound Pile with Reinforce) test pile, with skin friction being evaluated by the yield load and allowable bearing capacity after analyzing load-displacement curves and load-settlement curves. Results of the CPR test piles analyzed from the load-displacement curves show that the yield load and allowable bearing capacity of the large-diameter CPR test pile were about 1.4 times larger than that of the small-diameter pile. Results of the load-settlement curves reveal that the allowable bearing capacity of the CPR test pile with diameter of D500 was 1.2~2.1 times greater than that of the pile with diameter of D400. However, the allowable bearing capacity calculated using Fuller's analysis differed substantially from that determined using the P (Pull-out load) - S (Settlement) and log P - log S curves. Therefore, calculation of the allowable bearing capacity using Fuller's analysis is shown to be inappropriate.

Construction of Allowable Load Set for Multi-body Systems and Application Cases (다물체 시스템에서의 허용하중 집합의 구현과 적용)

  • Kim, J.H.;Kwak, B.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.758-763
    • /
    • 2001
  • A concept called Allowable Load Set (ALS) is introduced and methods of finding its boundaries are developed. The resulting diagram allows an easy understanding of load and strength characteristics of a structure in relation to structural integrity under uncertain loading conditions. An allowable load diagram for an ALS visualizes the relation between a prescribed load and a degree of safety of the structure. During the application of the algorithms, critical areas of the structure are identified. A systematic method of finding the allowable load sets for multi-body mechanical systems is especially presented and applied to an excavator as a realistic case.

  • PDF

Relations of Safety Factor and Reliability Index for Pile Load Capacity (말뚝 기초지지력에 대한 안전율과 신뢰도지수 평가)

  • Kim, Dae-Ho;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.466-475
    • /
    • 2006
  • Reliability analysis between safety factor and reliability index for driven and bored pile load capacity was analyzed in this study. 0.1B, Chin, De Beer, and Davisson's methods were used for determining pile load capacity by using load-settlement curve from pile load test. Each method define ultimate, yield and allowable pile load capacities. LCPC method using CPT results was performed for comparing with results of pile load test. Based on FOSM analysis using load factors, it is obtained that reliability indices for ultimate pile load capacity were higher than those of yield and allowable condition. Present safety factor 2 for yield and allowable load capacities are not enough to satisfy target reliability index $2.0\sim2.5$. However, it is sufficient for ultimate pile load capacity using safety factor 3.

  • PDF

Analysis of Load-Settlement Curves in Driven and Embedded Piles (항타 및 매입말뚝의 하중-침하량 곡선의 분석)

  • 천병식;조천환
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.61-70
    • /
    • 1997
  • Although the load -settlement curve characteristics of embedded piles are different from those of driven piles, for the determination of their allowable loads the same analysis method has been adopted without any considerations. According to the related domestic chi teria, the analysis methods of load-settlement curve have some conflicts among themselves and have several vague points in obtaining the allowable capacity from ultimate or yield capacity. In order to solve those problems, the relevant literatures were reviewed. And also the result of 106 pile load tests was analysed. Analysis result indicates that analysis met hods of the load-settlement curve based on single mathematical curve are not suitable for the general analysis method of load-settlement curves due to their various characteristics. As a result, the appropriate analysis methods and safety factors for the determination of allowable capacity of pile are suggested in this paper.

  • PDF

Characteristics for Current and Power of Induction Motor by Load Variation (부하변동에 따른 유도전동기 전류와 전력 특성)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.82-87
    • /
    • 2011
  • Induction motor is most widely used as the driving power in the industrial site. Induction motor current is composed of two parts, magnetizing current and load current. Load current uses energy what is doing the work. Load current varies with load variance but magnetizing current is constant, regardless of load variation. Magnetizing current needs for establishing the rotating magnetic field of induction motor and lags behind the voltage. Generally capacitor is used for power-factor compensation of inductive load. Self-excitation occurs when the capacitive reactive current from the capacitor is greater than the magnetizing current of the induction motor. When this occurs, excessive voltages can result on the terminals of the motor. This excessive voltage can cause insulation degradation and ultimately result in motor insulation failure. In this paper, we analyzed that how the magnetizing current and condenser current is operating at the allowable limit by the load variation. Condenser current is below allowable limit of magnetizing current but magnetizing current is above allowable limit at the lower load operation condition.

Compression strength performance of multi-layer glued columns by using square lumbers produced from domestic small diameter logs (국산 간벌 소경재를 이용한 다중접착접합 기둥부재의 압축강도성능)

  • Shin, Il-Joong;Kim, Yun-Hui;Jang, Sang-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.533-540
    • /
    • 2011
  • This study is to develop a mulit-layer glued columns for construction of Korean-style houses by using domestic small diameter logs. Dried small square lumber glued each other to develop a multi-layer glued columns and evaluated its performance of strength. Then, predicted the design load of multi-layer glued columns and make a comparison between actual load and design load of multi-layer glued columns. In the results, allowable load by allowable stress of multi-layer glued columns was measured one-third of actual columns load and prediction load was measured less than 10~30% of the actual load. Therefore, muilt-layer glued member has a standard allowable stress of compressive of 13 MPa (Larix leptolepis) and 19 MPa (Chamaecyparis obtusa) when used as columns. Also, using compression strength of small diameter square logs could calculate maximum loads of multi-layer glued member as column.

Characteristics of Bearing Capacity for H pile by Model Test (모형실험을 이용한 H말뚝의 지지력 특성)

  • 오세욱;이준대
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.99-105
    • /
    • 2001
  • This paper presents results km a series of model tests oil vertically loaded single piles to compare the behaviors of H and pipe piles under the same ground condition. The aims of this paper were to compare the bearing capacity of H-pile md pipe piles under in the same ground condition and to estimate the effect of gravity acceleration and relative soil density. Relative density of soil were made to be 40%, 80% and embedded length of pile on sand was increased by 10, 12, 14, 16 times of the diameter of pile, respectively. As a results of test series, allowable load of H-pile is from 6.4% to 18.2% larger than allowable load of pipe pile in relative density 80% and from 9.1% to 39.4% larger than allowable load of pipe pile in relative density 40%. As a results of numerical analysis, we were predicted behaviour of stress-displacement of pile with model test. In the case of relative density 80% and 40%, bearing capacity of H pile represent from 17.74% to 18.6% larger than allowable load of pipe pile.

  • PDF

Study(IV) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Field Verification of Long-term Allowable Compressive Load of PHC Piles by Analyzing Pile Load Test Results - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(IV) - 압축정재하시험 및 양방향재하시험 자료 분석을 통한 매입 PHC말뚝의 장기허용압축하중의 실증 성능 검증 -)

  • Lee, Wonje;Kim, Chae Min;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.9
    • /
    • pp.29-36
    • /
    • 2019
  • Axial compressive failure loads ($P_n$) of diameter 500 mm and diameter 600 mm A type PHC pile were calculated as 7.7 MN and 10.6 MN, respectively. In the static pile load tests, the maximum axial compressive loads of the above 2 kinds of A type pile were measured as 6.9 MN and 8.8 MN respectively, therefore these measured maximum loads were at the level of 90% and 83% of $P_n$ respectively. Long-term allowable axial compressive loads ($P_a$) of the above 2 kinds of A type pile were 1.7 MN and 2.3 MN respectively. From the bi-directional pile load test data on the prebored PHC piles, it was confirmed that the allowable axial compressive bearing resistance was estimated as 131% of the long-term allowable compressive load of the PHC pile and showed higher than the allowable bearing capacity calculated by the current design method. Therefore, it has been verified that the PHC pile can be used up to the maximum long-term allowable compressive load, and it is suggested that the ultimate pile capacity formula used in the current design for prebored PHC piles should be improved to accommodate the actual capacity.