• Title/Summary/Keyword: Alterative refrigerant

Search Result 4, Processing Time 0.021 seconds

A Study on Characteristics of HFC-l34a and OS-l2a Refrigerant in Automobile Air-Conditioning System (자동차 에어컨용 냉매인 HFC-134a와 OS-12a의 성능 특성에 관한 연구)

  • 이종인;하옥남
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.136-142
    • /
    • 2002
  • HFC-134a is currently used as the refrigerant in automobile air-conditioner, replacing the ozone depleting refrigerant CFC-12. Although HFC-l34a has no ozone depletion potential, it has a relatively high global warming potential, approximately 1300 tins that of CO$_2$ over a 100 year time horizon. Therefore, HFC- l34a does not seem to be a perfect alternative refrigerant due to high GWP. For this reason, non-azeotrope refrigerant mixture have been proposed as a long-term and drop-in alternative to HFC-l34a in the automobile air-conditioning system which has variable operating conditions with changes in RPM and pressure ratio. In this study,OS-l2a of which thermodynamic properties are similar to those of HFC-l34a is selected among the mixed refrigerant. HFC-l34a and OS-l2a are examined experimently by the performance test in the same automobile air-conditioning system.

접촉압력을 고려한 R-134a용 냉도기유의 윤활성 평가 연구

  • 나병철;전경진;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.145-151
    • /
    • 1997
  • PAG(Polyalkylene Glycol) and esters are tested with HFC-134a as a refrigeration oil. This investigation enhances the testing method by taking the compressor's environment into account. A testing environment charged with refrigerant gas more closely simulates the conditions of a compressor. The friction coetTicient of the PAG/HFC-134a system is similar to that of the mineral oil/CFC-12 system at operating conditions. Ester oils are preferable at the start & stop condition in the lubricity aspect. PAG shows good lubricity in conditions of extreme contact pressure. Consequently, this test provides reliable results on compressor lubricity of refrigeration oils with HFC-134a. It suggests a methodological way for the proper selection of refrigeration oils that may improve the durability and performance of a compressor.

  • PDF

Friction and Wear of the Vane/Roller Surfaces Depending on Several Sliding Condition for Rotary Compressor (여러 미끄럼 조건에 따른 로터리 압축기 베인/롤러 표면의 마찰 마멸 특성)

  • Lee, Young-Ze;Oh, Se-Doo;Kim, Jong-Woo;Kim, Cheol-Woo;Choi, Jin-Kyu;Cho, Sung-Ook
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.221-226
    • /
    • 2002
  • One of the serious challenges in developing rotary compressor with HFC refrigerant is the prediction of scuffing times and wear amounts between vane and roller surfaces. In this study, the tribological characteristics of sliding surfaces using vane-roller geometry of rotary compressor were investigated. The sliding tests were carried out under various sliding speeds, normal loads and surface roughness. During the test friction force, wear depth, time to failure and surface temperature were monitored. Because severe wear was occurred on vane surface, TiN coating was applied on sliding surfaces to prolong the wear-life of vane-roller interfaces. From the sliding test it was found that there was the optimum initial surface roughness to break in and to prolong the wear life of sliding surfaces. Depending on the load and speed, the protective layers, which were composed of metallic oxide and organic compound, were formed on sliding surfaces. Those would play an important role in role amounts of friction and wear between miler and vane surfaces.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.