• 제목/요약/키워드: Ambient ammonia concentration

검색결과 18건 처리시간 0.029초

환경수의 수온과 암모니아 농도 변화에 따른 쥐노래미(Hexagrammos otakii Jordan et Starks) 육성어의 산소소비와 암모니아 배설 (Effects of Water Temperature and Ambient Ammonia Concentration on Oxygen Consumption and Ammonia Excretion of Greenling Hexagrammos otakii Jordan et Stalks)

  • 김유희;김병기;김현주;조재윤;한원민;박정환
    • 한국수산과학회지
    • /
    • 제42권4호
    • /
    • pp.373-379
    • /
    • 2009
  • This study investigated oxygen consumption rate (OCR), $Q_{10}$ coefficient and ammonia excretion rate of the greenling, Hexagrammos otakii Jordan et Starks with the average body weight of 250 g in a semi-recirculated respiratory measuring system. The experiment was done under three different water temperatures (10, 15, $20^{\circ}C$) and five different ambient ammonia concentrations (0, 2.5, 5, 10, 20 mg/L). As the water temperature and ambient ammonia concentration increased the OCR has significantly increased (P<0.05). Given experimental conditions, the OCR of greenling were $50.8{\sim}159.4\;mg\;O_2\;kg^{-1}\;hr^{-1}$ and the relationship of water temperature (T) and ambient ammonia concentration (C) on the OCR were following: OCR = 41.3 - 1.87T - 7.38C + $0.463T^2$ + $0.66lC^2$ + 0.642TC - $0.011T^3$ - $0.010C^2$ - $0.031TC^2$ - $0.001T^2$C ($r^2$= 0.9226). $Q_{10}$ coefficients were $1.88{\sim}3.50$ for $10^{\circ}C$ to $15^{\circ}C$, $1.03{\sim}2.73$ for $15^{\circ}C$ to $20^{\circ}C$ and $1.40{\sim}1.90$ for $10^{\circ}C$ to $20^{\circ}C$, respectively. In general, the ammonia excretion rate tended to increase with increasing of the water temperature within normal ambient ammonia concentration. However, interestingly, it was observed that ammonia was absorbed rather than excreted above the ambient ammonia concentration of $2.5\;mg\;L^{-1}$, regardless of the water temperature. Thus, the largest ammonia absorption rate (AAR) was obserbed at the level of $98.4\;mg\;TAN\;kg^{-1}\;hr^{-1}$. The relationship ambient ammonia concentration (C) on AAR was following: Y = 1.61 + $10.9X^{0.7}$ ($r^2$ = 0.889).

논 토양에서 암모니아 배출 특성 모니터링을 위한 수동식 암모니아 확산형 포집기 이용 사례 연구 (A case study on monitoring the ambient ammonia concentration in paddy soil using a passive ammonia diffusive sampler)

  • 김민석;박민석;민현기;채은지;현승훈;김정규;구남인
    • 환경생물
    • /
    • 제39권1호
    • /
    • pp.100-107
    • /
    • 2021
  • 국내 고농도의 초미세먼지 발생 빈도 증가와 함께 그 전구물질인 NH3와 관련한 연구가 활발히 진행 중이다. NH3 배출에 있어 농업의 기여율이 높은 것은 자명한 사실이다. 그러나 비료 사용이 농경지 대기 중 NH3 농도에 장기간 미치는 영향에 관련한 연구는 미비한 실정이다. 따라서 본 연구에서는 수동식 NH3 확산형 포집기를 활용해 11개월간 농경지 대기 중 NH3 농도를 관측하였다. 그 결과 비료 살포 직후 한 달 동안 NH3 배출의 영향이 가장 큰 것으로 나타났다. 그 이후 여름철 기온 상승으로 NH3 휘발이 촉진되어 대기 중 농도가 증가할 것으로 예상하였으나, 54일간의 지속적인 강우로 인하여 대기 중 높은 암모니아 농도는 관측되지 않았다. 그 후 NH3 농도는 가을과 겨울을 거치면서 점차 감소하였다. 비료의 영향력이 감쇠한 시점 이후에는 기온이 감소할수록, 그리고 강수량이 증가할수록 NH3 농도는 감소하는 것을 상관분석을 통해 확인할 수 있었다. 종합해 보면, 국내 NH3 배출량에서 비료의 기여율을 연구하는 데 있어 비료 살포 직후 최소 한 달 동안은 집중적으로 살펴보아야 할 것이며, 현장 연구 시 강수량과 무강우 일수 등의 기상 정보도 함께 고려해야 할 것이다.

무창산란계사의 환경분석에 관한 연구 (Environmental Analysis in the Windowless Laying Hen Houses)

  • 이성현
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.225-230
    • /
    • 2003
  • This study was carried out to analyze the environmental variation of layer house at Iowa State in the USA. The analyzed seasons for this study were summer and winter. Analyzing factors are inside temperature and relative humidity, carbon dioxide concentration, ammonia concentration and emission. All factors were collected every 30 second from each house with portable monitoring units. In this study, two types of laying hen houses were monitored at the same season. One was a manure belt house, the other was a high-rise house. In order to estimate the ventilation rates of the laying hen houses, carbon dioxide concentration balance was used in this study. Ammonia concentrations and emission rates of the manure belt house are much lower than those of the high rise house. Daily mean ammonia concentrations in the manure belt house and high-rise house ranged from 3 to 7 ppm and 5 to 34 ppm, respectively. The daily ammonia emission rates averaged 0.68g/h$\cdot$500kg and 0.73g/h$\cdot$500kg for the manure belt house and 0.93g/h$\cdot$500kg and 2.89g/h$\cdot$500kg for the high-rise house in summertime and wintertime, respectively. Summertime is associated with much higher ammonia emission rates than wintertime because of much higher ventilation rates and ambient air temperature, even though the concentrations may be lower.

가스상 암모니아 측정을 위한 분석방법별 특성 연구 (Analysis Methods for Measurement of Ammonia Concentration)

  • 사재환;윤석경;노기환;전의찬
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.43-54
    • /
    • 2008
  • Management and control of ammonia at the sources and ambient largely depend on sampling and measurement techniques. Good sampling and measurement techniques provide high quality data. The main purpose of the study is compare the analytical characteristics of the Indolphenol method which is one of the standard method in Korea with automatic analyzers for continued measuring gaseous ammonia. For comparison with other analytical methods, the verification test was designed to evaluate performance parameters; linearity, absorption efficiency, reproducibility and repeatability test, accuracy, and response time test. $R^2$ of calibration curve using IPM and CLM was very high (value is 1.000), but for EcSM $R^2$ value was estimated to be lower than IPM and CLM (as 0.991). The RSD of the CLM ranged from 0.1 to 2.3% over the nine concentration levels measured, %Ds was 0.1 to 10.7%, and average RA over all the measurements was 3.3%. The RSD of IPM and EcSM was ranged from 1.0 to 8.1, 3.9 to 14.0 respectively, and average RA were 8.71, 4.9% respectively. Rise in response times of EcSM was estimated to be 1 minute. It is found to be more sensitive than response time (which ranged from 2 to 9 minute) of CLM. For ammonia concentration measured using the IPM and the CLM from the same ammonia source, linear regression of IPM versus CLM show a slope of 0.805, an intercept of 637 ppb, and $R^2$ of 0.868.

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권8호
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.

Effects of Aerosol Hygroscopicity on Fine Particle Mass Concentration and Light Extinction Coefficient at Seoul and Gosan in Korea

  • Choi, Eun-Kyung;Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권1호
    • /
    • pp.55-61
    • /
    • 2010
  • The sensitivity of aerosol light extinction coefficient to the aerosol chemical composition change is estimated by (1) calculating the aerosol water content and chemical concentrations by a gas/particle equilibrium model and (2) calculating the aerosol light extinction coefficient by a Mie theory based optical model. The major chemical species are total (gas and particle phase) sulfuric acid, total nitric acid, and total ammonia which are based on the measurement data at Seoul and Gosan. At Seoul, since there were enough ammonia to neutralize both total sulfuric acid and total nitric acid, the dry ionic concentration is most sensitive to the variation of the total nitric acid level, while the total mass concentration (ionic concentration plus water content) and thus, the aerosol light extinction coefficient are primarily determined by the total sulfuric acid. At Gosan, since the concentration of ambient sulfuric acid was the highest among the inorganic species, sulfate salts determined aerosol hygroscopicity. Thus, both ionic and total mass concentration, and resultant aerosol light extinction coefficient are primarily determined by the sulfuric acid level.

능성어 (Epinephelus septemfasciatus) 치어의 생존율과 혈액학적 특성 변화에 미치는 암모니아 노출의 영향 (Effects of Ammonia Exposure on Survival Rate and Hematological Characteristics Changes in Juveniles of Sevenband Grouper, Epinephelus septemfasciatus)

  • 김정현;박종연;이정용;이진환;황형규;조재권
    • 한국어류학회지
    • /
    • 제29권1호
    • /
    • pp.13-21
    • /
    • 2017
  • 본 연구는 능성어(Epinephelus septemfasciatus)를 해수 순환여과양식시스템(RAS)에 적용하는데 문제가 되는 암모니아의 농도 기준을 제시하기 위하여 96시간 동안 암모니아 노출에 따른 생존율 및 혈액학적 특성 변화를 조사하였다. 생존율 실험구의 암모니아 농도는 대조구, 0.35, 0.4, 0.5, 0.8 mg/L였으며, 96-h $LC_{50}$ 농도는 0.6 mg/L로 나타났다. 능성어 치어의 암모니아 96-h $LC_{50}$ 농도인 0.6 mg/L에서 0, 3, 6, 12, 24, 48, 72, 96시간 간격으로 12마리씩 혈액 샘플링을 하였다. 실험구의 암모니아 노출 시간이 경과할수록 혈장 코티졸, 글루코스, GOT 및 GPT 농도가 증가하는 경향을 보였다. 혈장 암모니아와 총 단백질은 암모니아 노출 12시간째까지는 증가하였고 이후로는 감소하였지만, 대조구와 비교하여 유의하게 높은 값을 나타내었다. 또한 혈장 전해질이온($Na^+$, $Cl^-$)과 삼투압은 감소하는 경향이 관찰되었다.

$MoO_3$를 첨가한 ZnO 박막 센서의 암모니아 가스 검지 특성 (Ammonia Gas Sensing Characteristics of ZnO Based Thin Film Sensor Doped with $MoO_3$)

  • 김성우;최우창;최혁환;이명교;권태하
    • 센서학회지
    • /
    • 제8권1호
    • /
    • pp.24-31
    • /
    • 1999
  • 감도가 우수하고 동작온도가 낮으며 반응속도가 빠른 암모니아 가스 센서를 제작하기 위해 ZnO에 촉매불순물 $MoO_3$의 첨가비와 박막 성장분위기 가스를 변화시키면서 RF 마그네트론 스펏터링 방법으로 박막을 성장하였다. 전기적 안정성을 향상시키기 위해 성장된 박막들을 aging 하여 센서를 제작한 후 암모니아 가스의 검지 특성을 조사하였다. 촉매불순물을 첨가하거나 산소분위기에서 성장된 박막의 경우 감도가 향상되었으며, 이는 표면 캐리어 농도와 전자이동도의 증가를 나타냈다. ZnO에 $MoO_3$를 무게비로 0.875 wt.% 첨가한 박막으로 제작한 센서가 160 ppm의 암모니아 가스 농도와 $300^{\circ}C$의 동작온도에서 70정도의 최대감도를 보였다. 산소분위기에서 $330^{\circ}C$로 72시간 동안 aging한 박막으로 만든 센서는 감도가 57정도로 감소하였으나, 센서의 동작온도가 $250^{\circ}C$로 낮아졌고, 선형성이 좋았으며 더 안정된 특성을 나타냈다.

  • PDF

매립지 악취가 주변 대기질에 미치는 영향 예측 - 청주청원 광역매립지 사례연구 - (Prediction of Malodorous Landfill Substances Effect on Ambient Air Quality - A Case Study on Cheongju·Cheongwon Metropolitan Landfill -)

  • 이상우
    • 환경영향평가
    • /
    • 제21권5호
    • /
    • pp.695-705
    • /
    • 2012
  • The purpose of this study is to investigate concentration level and characteristics of malodour substances generated from landfill site in C city. Also, it is tried to predict distribution of concentration level using ISCST3 model around landfill site. From the results, it can be confirmed that twelfth-class malodour substances such as ammonia, methyl mercaptan, hydrogen sulfide, dimethyl sulfate, dimethyl disulfate, toluene, acetaldehyde, styrene, propionaldehyde, butylaldehyde, n-Valeraldehyde, xylene were generated from landfill site. The levels of the malodour substances were lower than that of permeable concentration regulated by odor control law in Korea. However, the concentration of malodour substances including methyl mercaptan, hydrogen sulfide, acetaldehyde, and propionaldehyde exceeded threshold limit value(TLV). It was seemed that these substances caused the problem of offensive odor around circumstance of landfill. The concentration of malodour substances was higher in slant than in upper part of landfill. The concentrations of malodour substances measured at night time were shown higher level than those at night time because atmospheric condition was stable at night time. It showed that the concentration of malodour substances were higher in spring. The results of atmospheric diffusion model predicted that tolerance limit level of hydrogen sulfide and methyl mercaptan was detected within nearly 5km from the boundary of landfill.