• Title/Summary/Keyword: Anatomical fitting

Search Result 14, Processing Time 0.023 seconds

The review of literature;Treatment of a clavus with Fructus mume(烏梅) (("오매(烏梅)의 티눈치료(治療)" 에 관(關)한 문헌고찰(文獻考察))

  • Pang, Jong-Ki
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.43-54
    • /
    • 2008
  • The term keratosis covers a variety of growths such as warts and pressure-induced callosities. Warts develop in the absence of pressure, and often clear up again after a certain period, usually without treatment. Clavi can develop as a result of wearing poorly fitting shoes, but also deformed toes or other anatomical deformities affecting the foot. The resulting non-anatomical stressing leads to the formation of pressure callosities and even to pressure sores. It confronts hereupon, it searched the cure against the clavus with fructus mume(烏梅) and it arranged. The possibility of getting the result regarding the clavus treatment with fructus mume(烏梅) from the oriental medicine it was.

  • PDF

Automatic Segmentation of Vertebral Arteries in Head and Neck CT Angiography Images

  • Lee, Min Jin;Hong, Helen
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.67-70
    • /
    • 2015
  • We propose an automatic vessel segmentation method of vertebral arteries in CT angiography using combined circular and cylindrical model fitting. First, to generate multi-segmented volumes, whole volume is automatically divided into four segments by anatomical properties of bone structures along z-axis of head and neck. To define an optimal volume circumscribing vertebral arteries, anterior-posterior bounding and side boundaries are defined as initial extracted vessel region. Second, the initial vessel candidates are tracked using circular model fitting. Since boundaries of the vertebral arteries are ambiguous in case the arteries pass through the transverse foramen in the cervical vertebra, the circle model is extended along z-axis to cylinder model for considering additional vessel information of neighboring slices. Finally, the boundaries of the vertebral arteries are detected using graph-cut optimization. From the experiments, the proposed method provides accurate results without bone artifacts and eroded vessels in the cervical vertebra.

Development of Three-Dimensional Contact Model of Human Knee Joint During Locomotion (보행 중 인체 슬관절의 3차원 접촉 모델 개발)

  • Kim, Hyo-Shin;Park, Seong-Jin;Mun, Joung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.182-189
    • /
    • 2005
  • The human knee joint is the intermediate joint of the lower limb that is the largest and most complex joint in the body. Understanding of joint-articulating surface motion is essential for the joint wear, stability, mobility, degeneration, determination of proper diagnosis and so on. However, many studies analyzed the passive motion of the lower limb because of the skin marker artefact and some studies described medial and lateral condyle of a femur as a simple sphere due to the complexity of geometry. Thus, in this paper, we constructed a three-dimensional geometric model of the human knee from the geometry of its anatomical structures using non-uniform B-spline surface fitting as a study for the kinematic analysis of more realistic human knee model. In addition, we developed and verified 6-DOF contact model of the human knee joint using $C^2$ continuous surface of the inferior region of a femur, considering the relative motion of shank to thigh during locomotion.

Design of A Human Model of the Moving-Actuator Type Total Artificial Heart

  • Chang, Jun-Keun;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.65-70
    • /
    • 1997
  • A human version of Korean total artificial heart(TAM) was designed basso on the magnetic resonance imaging(MRI) data To obtain accurate measurement or human thoracic structure including the valvular sited we analyzed the dimensions of the natural heart of healthy persons and cardiomyopathy(CM) patients. The MRI findings were analyzed to measure the volume of the thoracic cavity that would be occupied by the TAM. The design upgrade of the mechanical performed was also performed with the computer aided design(CAD) system to develop a new version of Korean TAH.

  • PDF

Parametric Shape Modeling of Femurs Using Statistical Shape Analysis (통계적 형상 분석을 이용한 대퇴골의 파라메트릭 형상 모델링)

  • Choi, Myung Hwan;Koo, Bon Yeol;Chae, Je Wook;Kim, Jay Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1139-1145
    • /
    • 2014
  • Creation of a human skeleton model and characterization of the variation in the bone shape are fundamentally important in many applications of biomechanics. In this paper, we present a parametric shape modeling method for femurs that is based on extracting the main parameter of variations of the femur shape from a 3D model database by using statistical shape analysis. For this shape analysis, principal component analysis (PCA) is used. Application of the PCA to 3D data requires bringing all the models in correspondence to each other. For this reason, anatomical landmarks are used for guiding the deformation of the template model to fit the 3D model data. After subsequent application of PCA to a set of femur models, we calculate the correlation between the dominant components of shape variability for a target population and the anatomical parameters of the femur shape. Finally, we provide tools for visualizing and creating the femur shape using the main parameter of femur shape variation.

Transmit Receive RF Resonator Optimization at 7 T MRI System (7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화)

  • Alam, Mohammad Wajih;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1727-1730
    • /
    • 2016
  • Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.

A novel technique for large and ptotic breast reconstruction using a latissimus dorsi myocutaneous flap set at the posterior aspect, combined with a silicone implant, following tissue expander surgery

  • Ishii, Naohiro;Ando, Jiro;Shimizu, Yusuke;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.484-489
    • /
    • 2018
  • Large and ptotic breast reconstruction in patients who are not candidates for a transverse rectus abdominalis myocutaneous flap and revision surgery for the contralateral breast remains challenging. We developed a novel breast reconstruction technique using a latissimus dorsi myocutaneous (LD m-c) flap set at the posterior aspect of the reconstructed breast, combined with an anatomical silicone breast implant (SBI), following tissue expander surgery. We performed the proposed technique in four patients, in whom the weight of the resected tissue during mastectomy was >500 g and the depth of the inframammary fold (IMF) was >3 cm. After over-expansion of the lower portion of the skin envelope by a tissue expander, the LD m-c flap was transferred to cover the lower portion of the breast defect and to achieve a ptotic contour, with the skin paddle set at the posterior aspect of the reconstructed breast. An SBI was then placed in the rest of the breast defect after setting the LD m-c flap. No major complications were observed during the follow-up period. The proposed technique resulted in symmetrical and aesthetically satisfactory breasts with deep IMFs, which allowed proper fitting of the brassiere, following large and ptotic breast reconstruction.

임상전단계의 완전 이식형 인공심장 시스템 개발

  • Min, Byeong-Gu;An, Jae-Mok;Park, Chan-Yeong;Jo, Yeong-Ho;Choi, Won-Woo;Kim, Hyeon-Jeong;Park, Seong-Geun;Lee, Jong-Jin;Choi, Jae-Sun;Eom, Gyeong-Sik;Kim, Jong-Won;Jang, Jun-Geun;Kim, Hui-Chan;Kim, Won-Gon;Won, Yong-Sun;No, Jun-Ryang
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.125-128
    • /
    • 1996
  • A new type of motor-driven total artificial heart system with a moving-actuator mechanism has been developed. The prototype system consists of a brushless do motor inside of actuator, two polyurethane sacs, and peripheral devices with internal controller. In this research work, the moving-actuator type electromechanical total artificial heart was redesigned for a good anatomical fitting. For total implantation we are developing the internal controller with high reliability and stability, and automatic control algorithm in response to the physiological requirements of animal. Contents and scope of the research work on ";Development of a totally implantable artificial heart of pre-clinical stage"; is summerized below 1) Animal experiment using sheep(55-60kg) 2) Development of implantable controller 3) Automatic control algorithm 4) Improvement of biocompatibility 5) Redesign of Actuator/blood pump.

  • PDF

Experimental Implantation of Moving Actuator Type Total Artificial Heart in Sheep (양에서 시행한 이동작동기 형태(MOVING ACTUATOR TYPE) 인공심장의 삽입실험)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.533-541
    • /
    • 1995
  • We recently developed a new model of moving actuator type totally implantable artificial heart[TIAH , based on the reverse position of the aortic and pulmonary conduits. This concept was proposed by one of surgeons in our team[Joon-Ryang Rho, M.D. to facilitate anatomical fitting of TIAHs. The moving actuator type electromechanical TIAH consisted of the left and right blood sacs, and the moving actuator including a motor. The inverted umbrella type polyurethane valves were used in the blood pumps. The aortic conduit was positioned anterior to the pulmonary conduit, which was the opposite relation to the conventional configuration of other total artificial hearts. We also adapted slip-in connectors for the aortic and pulmonary conduits. Two sheep , weighing 60-69 kg, were used for implantation. After small cervical incision and trans-sternal bilateral thoracotomy, cardiopulmonary bypass [CPB was administered using an American Optical 5-head pump and a membrane oxygenator[Univox-IC, Bentley . The anterior and posterior vena cavae were drained separately for venous return. An arterial return cannula was inserted into the right common carotid artery. During CPB, almost all of the ventricular myocardium was excised down to the atrioventricular groove and the artificial heart was implanted. We achieved 3-day survival in the first sheep and 2-day survival in the second. The day after operation the first sheep was successfully extubated and the second sheep was weaned from a respirator with good condition. After extubation, the first sheep walked around in the cage and fed herself. Serial laboratory and hemodynamic examinations were done during the experiments. In both sheep, pulmonary dysfunction was gradually developed, which was accompanied by acute renal failure. The animals were sacrificed and autopsy was done. Unexpected pregnnacy was incidentally found in both sheep. To our knowledge this is the first report of significant survival cases in the orthotopic implantation of electric TIAH using sheep.

  • PDF

Resonance Changes in the External Auditory Canal Associated with the Ear Canal Volume (외이도용적에 따른 외이도공명의 변화)

  • Choi, Ah-Hyun;Lee, Mi-So;Choi, Ah-Reum;Heo, Seung-Deok
    • Phonetics and Speech Sciences
    • /
    • v.1 no.3
    • /
    • pp.151-154
    • /
    • 2009
  • The external ear generates resonance gain because of anatomical characteristics. The ear canal resonance is influenced by the length and volume of the ear canal, the pinna, the concha cavity, the body trunk, and the speed of sound wave. This study is focus on the influence of the volume of ear canal. 17-healthy-adult (32 ears) were participated. They did not have any medical and ear disease history. The maximum resonance frequency of the ear canal was 2675 (${\pm}265$) Hz at azimuth $0^{\circ}$ and 2784 (${\pm}268$) Hz at azimuth $45^{\circ}$. The resonance gain was 18.1 (${\pm}3.9$) dB at azimuth $0^{\circ}$ and 17.9 (${\pm}3.8$) dB at azimuth $45^{\circ}$, respectively. The ear canal volume was 0.78 (${\pm}0.2$) cc and 1.32 (${\pm}0.8$) cc including static compliance. The ear canal resonance was changed depending on the ear canal volume. It was also statistically correlated at azimuth $0^{\circ}$ (p=0.038) and $45^{\circ}$ (p=0.013), respectively. The resonance gain was not correlated with the ear canal volume. The change of resonance frequency according to the ear canal volume will be useful information in the field of audiological rehabilitation especially for hearing aids fitting. In addition, we expected this study can provide the basic information for the study of the external ear resonance characteristics.

  • PDF