• Title/Summary/Keyword: Anchor tension

Search Result 115, Processing Time 0.027 seconds

Development of Composite Tension.Compression Anchor System based on the pull out resistance characteristics of Ground Anchor (지반앵커의 인발저항 특성에 따른 인장.압축 복합 시스템 개발)

  • Yeom, Ho-Hyeong;Im, Jong-Chul;Hong, Seok-Woo;Kim, Chul-Ung;Shin, Chul-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.788-795
    • /
    • 2005
  • In this study, the progressive failure and creep of the traditional ground anchor structure were decreased and a new ground anchor that can attain the required pull-out resistance even in soft sandy soils with low confining pressure was developed. Ground anchors are classified depending on the kind of stress the grout is subjected. If the grout material is subjected to tension then it is classified as tension anchor while when the grout material is subjected to compression it is classified as compression anchor. The ground anchor that possesses both the tension and compression mechanism mentioned above is known as composition anchor. It is the objective of this study to develope this type of composition anchor. The structure of the newly developed ground anchor was presented. Pull-out test in different types of soil and the behaviour during Pull-out test was also presented.

  • PDF

Experimental Study on Pullout Behavior of Composite Type Ground Anchor (복합형 앵커의 인발거동에 관한 실험적 연구)

  • Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.143-155
    • /
    • 2008
  • Ground anchors are classified depending on the kind of stress the grout is subjected to. If the grout material is subjected to tension then it is classified as tension anchor while when the grout material is subjected to compression it is classified as compression anchor. In this study a composite type anchor that possesses both the tension and compression mechanism was developed. For field tests, strain gauges were installed inside the anchor body in soft: soil. From the strain monitoring results, pull-out resistance mechanism that possesses both tension and compression strain was seen.

The Study on Pullout Resistance Characteristics of the Compression Anchor by Pullout Tests on the Field (현장실험에 의한 압축형 앵커의 인발거동특성 연구)

  • 홍석우
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.44-52
    • /
    • 2002
  • The mechanism of pullout resistance of compression anchor is analysed. This anchor is developed through the field pullout tests and the laboratory element test. The compression anchor is characterized by decrease of progressive failure, simple site work, economy and durability compared with tension anchor. The characteristics of compression anchor, compared with tension anchor. mainly are summarized as follows ; (1) The plastic displacement of anchor body is very small during pullout of anchor. (2) Total anchor length decreases by the shortening of free length; (3) The progressive failure is decreased.; (4) The safety factor for pullout resistance increases with time after construction of anchor.

Pullout Behavior of Typical friction Anchors and Development of Design Method (앵커 형식별 인발거동과 설계법 개발)

  • 송일준;김가야;홍석우
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.43-51
    • /
    • 2003
  • The resistance mechanism of anchor changes according to the types of anchor. Friction anchors are classified into tension and compression types. In this study, the characteristics and mechanism of pullout are analysed, and the design method of anchor and computer program for design are developed through compression test results of anchor body grout. The characteristics of compression anchor, compared with tension anchor, are summarized mainly as follows: (1) The effect of progressive failure of compression anchor body are much smaller than those of tension anchor during pullout of anchor: (2) The skin friction resistance is increased by Possion effect of grout (anchor body) during pullout of compression anchor.

Strength of Anchors under Load Applied Angles (앵커볼트의 내력평가에 관한 실험적 연구)

  • Kim, Sung-Yong;Han, Duck-Jeon;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.1 s.16
    • /
    • pp.69-76
    • /
    • 2005
  • The pull-out capacity of expansion anchor(heavy duty anchor and wedge anchor) was studied experimentally in this paper. Loading conditions included tension, shear, and combined tension and shear. The heavy duty anchor and wedge anchor were manufactured in domestic and installed In plain concrete. The failure mode of steel and concrete were studied carefully for the analytical formula of the anchorage design and the experimental data were compared with different models for the interaction of tension and shear capacities. Based on the research, the following conclusion may be drawn : The interaction of forces is well-described by an elliptical interaction relationship.

A Study on the Change of Tensile Force of Friction Type Anchor under Shear Deformation of Ground (지반의 전단변형에 따른 마찰형 앵커의 긴장력 변화에 대한 연구)

  • You, Min-Ku;Kwon, O-Il;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.13-25
    • /
    • 2018
  • When deformation occurs on slope reinforced with anchor, shear stress and bending stress are applied on the shear surface along the slip surface and increase of the shear deformation causes the tension force variation of the anchor. In this study, shear test was performed by measuring the tension force of the anchor by inducing shear deformation in vertical direction of the anchor using a large-scale direct shear test equipment in order to confirm the tension force variation of the anchor induced by shear deformation. The shear test was performed for 8 conditions which were classified according to the anchor reinforcement, separation distance (1D, 2D, 4D) from the shear surface to bonded part and the lateral-pressure condition (0.1 MPa, 0.2 MPa) of adjacent ground. As a result of the shear test, it was found that the separation distance and the lateral-pressure condition affect the shear force of the ground reinforced by anchor and the tension force of the anchor, and experimentally verified that the shear force variation is related to axial force variation of the anchor head and tip. Therefore, it was confirmed that the behavior of the bonded part induced by the shear deformation can be indirectly predicted by analyzing the tendency of the tension force variation of the anchor head.

Characteristic of holding power due to nature of seabed at anchor (묘박중 해저 저질에 따른 파주력 특성)

  • KIM, Byung-Yeob;KIM, Kwang-il;KIM, Min-son;NOBUO, Kimura;LEE, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.3
    • /
    • pp.230-240
    • /
    • 2022
  • In general, a high tension on the anchor and chain is placed when a ship at anchor is subjected to heavy weather. Mariners have to pay attention to whether dragging anchor occurs to keep the safety of the ship at anchorage since it is difficult to maintain the stable motion of ship and it causes collisions with other ships nearby. In this paper, the ship motion against the external forces was shown to obtain the fundamental data about characteristic of holding power due to nature of seabed at anchor, so practical trials were carried out in rocky area and muddy area using a trial ship around coastal area of South Korea. In muddy seabed, holding power showed reasonable tension values depending on the distance from anchor position of continuing swing motions of a ship corresponding to wind force. Meanwhile in rocky seabed, tension values on the chain appeared very high occasionally regardless of the distance from the anchor position and seemed to exceed its holding power to be the breaking strain of the chain although weather was not in a severe condition. Therefore, some of the cables laid on the seabed were presumed to be caught in a crack on the rock. It is assumed that even a small amount of external force may cause the chain to break in a moment in rocky seabed. Additionally, wind and current forces had a somewhat contradictory effect on holding power of the ship between them.

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

Development of Removable-Strand Compression Anchor (압축형 제거 앵커의 개발 및 성능 평가)

  • 김낙경;김성규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.339-346
    • /
    • 2001
  • For temporary excavation support in private land area, the strand of ground anchor should be removed In order to get permission to install anchors. The extractable or removable-strand compression anchor system was developed and evaluated by a series of pull-out load tests. Anchor pull-out tests were performed on seven instrumented full-scale low-pressure grouted anchors installed in weathered soil at the Geotechnical Experimentation Site at Sungkyunkwan University, Four anchors are the compression type anchors and three are the tension anchors. Performance test, creep test, and long term relaxation test were performed and presented. Load distributor was developed in order to distribute large compressive stresses in grout.

  • PDF