• Title/Summary/Keyword: Antecedent day

Search Result 28, Processing Time 0.021 seconds

Determination of Suitable Antecedent Precipitation Day for the Application of NRCS Method in the Korean Basin (NRCS 유효우량 산정방법의 국내유역 적용을 위한 적정 선행강우일 결정 방안)

  • Lee, Myoung Woo;Yi, Choong Sung;Kim, Hung Soo;Shim, Myung Pil
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Generally the estimation of effective rainfall is important in the rainfall-runoff analysis. So, we must pay attention to selecting more accurate effective rainfall estimation method. Although there are many effective rainfall estimation methods, the NRCS method is widely used for the estimation of effective rainfall in the ungaged basin. However, the NRCS method was developed based on the characteristics of the river basin in USA. So, it may have problems to use the NRSC method in Korea without its verification. In the NRCS method, the antecedent precipitation of 5-day is usually used for the estimation of effective rainfall. The main purpose of this study is to investigate the suitable antecedent precipitation day in Korea river basin through the case study. This study performs the rainfall-runoff simulation for the Tanbu river basin by HEC-HMS model under the condition of varying the antecedent precipitation day from 1-day to 7-day and performs goodness of fit test by Monte Carlo simulation method. The antecedent precipitation of 2-day shows the most preferable result in the analysis. This result indicates that the NRCS method should be applied with caution according to the characteristics of the river basin.

  • PDF

The Effect of Antecedent Moisture Conditions on the Contributions of Runoff Components to Stormflow in the Coniferous Forest Catchment

  • Choi, Hyung-Tae;Kim, Kyong-Ha;Lee, Choong-Hwa
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.5
    • /
    • pp.755-761
    • /
    • 2010
  • This study analyzed water quality data from a coniferous forest catchment in order to quantify the contributions of runoff components to stormflow, and to understand the effects of antecedent moisture conditions within catchment on the contributions of runoff components. Hydrograph separation by the twocomponent mixing model analysis was used to partition stormflow discharge into pre-event and event components for total 10 events in 2005 and 2008. To simplify the analysis, this study used single geochemical tracer with Na+. The result shows that the average contributions of event water and pre-event water were 34.8% and 65.2% of total stormflow of all 10 events, respectively. The event water contributions for each event varied from 18.8% to 47.9%. As the results of correlation analysis between event water contributions versus some storm event characteristics, 10 day antecedent rainfall and 1 day antecedent streamflow are significantly correlated with event water contributions. These results can provide insight which will contribute to understand the importance of antecedent moisture conditions in the generation of event water, and be used basic information to stormflow generation process in forest catchment.

Re-establishing the Antecedent Moisture Condition of NRCS-CN Method Considering Rainfall-Runoff Characteristics in Watershed Based on Antecedent 5-Day Rainfall (유역의 강우-유출 특성을 고려한 NRCS-CN 방법의 선행토양함수조건의 재설정: 선행5일강우량을 기준으로)

  • Yoo, Ji-Young;Moon, Geon-Woo;Ahn, Jae-Hyun;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.849-858
    • /
    • 2014
  • The mount of antecedent 5-day rainfall (P5) is usually used to determine the antecedent soil moisture condition for estimating effective rainfall using the NRCS-CN method. In order to re-establish the threshold of P5 considering basin characteristics, this study investigated the sensitivity of the threshold of P5 to effective rainfall by comparing the corresponding observed direct runoff. The overall results indicate that the direct runoff estimated using the re-establihed threshold of P5 has smaller mean error (RMSE of 27.3 mm) than those using the conventional threshold (RMSE of 35.2 mm). In addition, after evaluating the effectiveness of threshold of P5 using the improvement index, the threshold re-established in this study improved the ability to estimate the direct runoff by 30% on average. This study also suggested to employ regression models using topographic indices to re-establish the threshold for ungauged basins. When using the re-established threshold from the regression model, the RMSE decreased ranging from 0.4 mm to 15.1 mm and the efficiency index of Nash and Sutcliffe increased up to 0.33.

Revised AMC for the Application of SCS Method (SCS 유효우량 산정방법 적용을 위한 선행토양함수조건의 재설정(장평유역을 중심으로))

  • Park, Cheong-Hoon;Yoo, Chul-Sang;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.578-582
    • /
    • 2005
  • In this study, the conceptual foundation and development process of the Antecedent soil Moisture Condition(AMC) in SCS runoff curve number method are reviewed. Although the runoff volume is very sensitive with AMC condition, the AMC class limits developed in SCS(1972) are used in rainfall-runoff analysis without careful consideration. Tn this study, following the SCS curve number development process, rainfall-runoff characteristics of the Jang-Pyung subbasin subject to the Pyung-Chang River basin are analyzed to evaluate the reasonability of the AMC class limits at present. The New AMC class limits are proposed by the sensitive analysis of the antecedent rainfall - curve number value. As a result, the classification value of AMC-I with II is 22mm of antecedent 5-day rainfall amount, and the classification of AMC-II with III is 117mm in growing season. When the New AMC class limits are applied to Jang-Pyung subbasin, AMC probability distribution shows that the AMC-II has increased remarkably even though the AMC-I has a little higher value. But the AMC-III has the smallest one. According to the conceptual basis of the curve number method, the AMC probability distribution, the New AMC class limits adopted, gives reasonable results.

  • PDF

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Sweet Potato Plot - (강우시 비점오염원의 오염부하 특성 - 고구마 재배지를 대상으로 -)

  • Kang, Mee-A;Jo, Soo-Hyun;Choi, Byoung-Woo;Yoon, Young-Sam;Lee, Jae-Kwan
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.365-371
    • /
    • 2009
  • This paper address the characteristics of loading pollutants caused by the unit agricultural area to establish an efficient management method in NPS (non-point source). The relationship between rainfall and runoff shows good coefficient with 0.92, when the event which shows relatively long antecedent dry days is excepted. The impact of runoff volume on the runoff coefficient can be described by the rainfall intensity strongly. The pollutant EMCs (event mean concentrations) in runoff increased by the increase of antecedent dry days due to dry soil conditions. As the similar pattern of pollutant's loads such as TSS, BOD, COD, TN and TP, it is cleared that other pollutants can be removed when TSS is removed. Therefore the system using only runoff coefficients is not sufficient for the prediction of pollutant loads. It is necessary to consider soil conditions such as rainfall, antecedent dry day, antecedent rainfall etc. for the prediction system.

Water conservation effect of concave greenroof system and its influential factors (오목형 옥상녹화의 수자원확보효과와 영향인자)

  • Baek, So-Young;Han, Moo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.165-169
    • /
    • 2015
  • Green roofs are gaining much interest in many cities around the world due to its multi-purpose effects of water conservation, flood mitigation and aesthetic benefits. However it may cause additional water demand to maintain green plants, which may intensify the current and future water shortage problems. While ordinary concrete roofs and normal green roof drains off rain water, concave green roof system can retain rain water because of its water holding capability. In this study, the water conservation effect of concave green roof was compared to normal roof on #35 building in Seoul National University, Seoul, Korea. For seven rainfall events the amount of stored rainwater and runoff were measured and proved water conservation effect of the concave green roof system. The concave green roof system of which area is 140m2 showed effect of water conservation from 1.8ton to 7.2ton and the most influence factors on water conservation in green roof are rainfall and antecedent day. If this concave green roof is applied to many buildings in the cities, it is expected as a way to water conservation through rainfall storage.

Analysis of pollutant build-up model applied to various urban landuse

  • Choi, Jiyeon;Na, Eunhye;Ryu, Jichul;Kim, Jinsun;Kim, Hongtae;Shin, Dongsuk
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • This study was conducted to analyse the application of pollutant build-up model on various urban landuses and to characterize pollutant build-up on urban areas as a source of stormwater runoff pollution. The monitored data from impervious surfaces in urban areas such as commercial (8 sites), industrial (10 sites), road (8 sites), residential (10 sites), recreational (5 sites) from 2008 to 2016 were used for the analysis of pollutant build-up model. Based on the results, the average runoff coefficients vary from 0.35 to 0.61. In all landuses except recreational landuse, the runoff coefficient is 0.5 or more, which is the highest in the commercial area. Commercial landuse where pollutants occur at the highest EMC in all landuse, and it is considered that NPS management is necessary compared with other landuses. The maximum build-up load for organic matter (BOD) was highest in the commercial area ($4.59g/m^2$), and for particular matter (TSS) in the road area ($5.90g/m^2$) while for nutrient (TN and TP) in the residential area ($0.40g/m^2$, $0.14g/m^2$). The rate constants ranged from 0.1 to 1.3 1/day depending on landuse and pollutant parameters, which means that pollutant accumulation occurs between 1 and 10 days during dry day. It is clear that these build-up curves can generally be classified based on landuse. Antecedent dry day (ADD) is a suitable and reasonable variable for developing pollutant build-up functions. The pollutant build-up curves for different landuse shows that these build-up curves can be generally categorized based on landuse.

Investigation of Water Quality and Hydrological Characteristic When Red Tide Develop in the Mouth of Hyeongsan River (형산강 하류 적조발생시 수질 및 수문학적 특성 검토)

  • Lee, Chang-Soo
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1155-1162
    • /
    • 2009
  • To investigate the influence of water area calmness on the red tide development, runoff phenomena due to antecedent precipitation of red tide development day were analyzed. There were examined the water quality variation properties at about the same time of the red tide develop. The red tide was developed when the stage and discharge nearly had not changed. It was estimated that the stability of particle behavior in the mouth of river effected on the red tide develop. Also, the concentrations of $COD_{Mn}$ were increased about 241~629% when the red tide developed.

A Study on the Characteristics of Antecedent Meteorologic Conditions on High Ozone Days in Busan (부산지역 고농도 오존일의 선행 기상 특성 연구)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.993-1001
    • /
    • 2015
  • Comparing to the other air pollutants like $SO_2$, CO, the number of exceedance of the ozone national ambient air quality standard(NAAQS) and the ozone warning increased recently in Busan. The purpose of this study is to find out the preliminary symptoms for high ozone days in Busan area. In order to find out the preliminary symptoms, the hourly ozone data at air quality monitoring stations and the hourly meterological parameters at Busan regional meteorological 2007 to 2013 were used for the analysis. Averaged daily max ozone concentration was the highest(0.055 ppm) at Noksan and Youngsuri in the ozone season from 2007 to 2013. The horizontal distributions of daily max. ozone including all stations in Busan at high ozone days(the day exceeding 0.1 ppm of ozone concentration at least one station) were classified from two to five clusters by hierarchial cluster analysis. The meteorological variables showing strong correlation with daily max. ozone were the daily mean dew point temperature, averaged total insolation, the daily mean relative humidity and the daily mean cloud amount. And the most frequent levels were $19-23^{\circ}C$ in dew point temperature, $21-24 MJ/m^2$ in total insolation on the day before, $2.6-3.0 MJ/m^2$ on the very day, 67-80% in relative humidity and 0-3 in cloud amount.

Derivation of Transfer Function Models in each Antecedent Precipitation Index for Real-time Streamflow Forecasting (실시간 유출예측을 위한 선행강우지수별 TF모형의 유도)

  • Nahm, Sun Woo;Park, Sang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 1992
  • Stochastic rainfall-runoff process model which is mainly used in real-time streamflow forecasting is Transfer Function(TF) model that has a simple structure and can be easy to formulate state-space model. However, in order to forecast the streamflow accurately in real-time using the TF model, it is not only necessary to determine accurate structure of the model but also required to reduce forecasting error in early stage. In this study, after introducing 5-day Antecedent Precipitation Index (API5), which represents the initial soil moisture condition of the watershed, by using the threshold concept, the TF models in each API5 are identified by Box-Jenkins method and the results are compared with each other.

  • PDF