Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.