• Title/Summary/Keyword: Application technology

Search Result 20,252, Processing Time 0.048 seconds

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

Advanced Network 응용 및 활용 사례: Application Technology 분야

  • 김종원;강신각;신지태;김현철
    • Information and Communications Magazine
    • /
    • v.20 no.10
    • /
    • pp.121-130
    • /
    • 2003
  • 1997년 활동을 시작한 APAN-KR (Asia Pacific Advanced Network - Korea) Technology Area 활동을 계승하여 2003년 초에 재구성된 ANF (Advanced Network Forum: 한국첨단망협회) Application Technology Area에 대한 전반적인 소개에 이어서 VoIP (voice over IP), DV/VC(digital video / video conferencing) 및 P2P(peer to peer)로 나누어진 각 세부 WG (working group)들의 소개, 활동 내용, 향후 계획 등을 살펴본다.

Differential die-away technology applied to detect special nuclear materials

  • Lianjun Zhang;Mengjiao Tang;Chen Zhang;Yulai Zheng;Yong Li;Chao Liu;Qiang Wang;Guobao Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2483-2488
    • /
    • 2023
  • Differential die-away analysis (DDAA) technology is a special nuclear material (SNM) active detection analysis technology. Be a nuclear material shielded or not, the technology can reveal the existence of nuclear materials by inducing fission from an external pulsed neutron source. In this paper, a detection model based on DDAA analysis technology was established by geant4 Monte Carlo simulation software, and the optimal sensitivity of the detection system is achieved by optimizing different configurations. After the geant4 simulation and optimization, a prototype was established, and experimental research was carried out. The result shows that the prototype can detect 200 g of 235U in a steel cylinder shield that's of 1.5 cm in inner diameter, 10 cm in thickness and 280 kg in weight.

The Effect of Information Technology Application on Knowledge Management Process in Clinical Nurses (간호사의 정보기술(IT)활용이 지식관리활동에 미치는 영향)

  • Jeong, Seok-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.10 no.1
    • /
    • pp.141-159
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the degree of information technology application, and to identify the effect of information technology application en knowledge management process in clinical nurses. Method: Participants were 629 regular clinical nurses who had worked for over 1 year in general units of 9 tertiary medical hospitals including 2 national university hospitals, 5 university hospitals, and 2 hospitals founded by business enterprises. Data were collected from March to May 2003 through questionnaires. Thee structured instruments were used to collect the data: Information Technology Application scale, Knowledge Management Process Scale(Jeong, Lee, Lee, & Kim, 2003), and one for general characteristics. The data were analyzed using reliability analysis, descriptive analysis, one-way ANOVA, $Scheff{\acute{e}$ test, correlation analysis, partial correlation analysis, and multiple regression analysis with the SPSS for Windows 10,0 program. Result: 1) The HIS application degree, IT application ability, and IT application frequency were significantly correlated with the degree of knowledge management process activation and 4 elements of knowledge management process, Knowledge Creation, Knowledge Storage, Knowledge Sharing, and Knowledge Utilization(p=.000). 2) The 3 variables, HIS application degree, IT application ability, and IT application frequency explained 47.2% of the total variance of the degree of knowledge management process activation, and 352% of me total variance of Knowledge Storage. And 2 variables, HIS application degree and IT application frequency explained 17.6% of the total variance of Knowledge Creation, 39.9% of the total variance of Knowledge sharing, and 33.8% of the total variance of Knowledge utilization(p=.000). 3) As a result of multiple regression analysis, the key determinant of the degree of knowledge management process activation for nurses was HIS application degree The HIS application degree, IT application frequency, position, IT application ability, and continuous total numbers of years working at the present hospital explained 51.1% of the total variance of the degree of knowledge management process activation(p=.000). Conclusions: These results suggest that the information technology application positively affects the nurses' knowledge management process. From the above findings, information technology application is empirically verified as a useful and effective method to activate knowledge management process, and knowledge management.

  • PDF

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

A field determination method of D-T neutron source yields based on oxygen prompt gamma rays

  • Xiongjie Zhang;Bin Tang ;Geng Nian;Haitao Wang ;Lijiao Zhang ;Yan Zhang ;Rui Chen ;Zhifeng Liu ;Jinhui Qu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2572-2577
    • /
    • 2023
  • A field determination method for small D-T neutron source yield based on the oxygen prompt gamma rays was established. A neutron-gamma transport equation of the determination device was developed. Two yield field determination devices with a thickness of 20 mm and 50 mm were made. The count rates of the oxygen prompt gamma rays were calculated using three energy spectra processing approaches, which were the characteristic peak of 6.13 MeV, the overlapping peak of 6.92 MeV and 7.12 MeV, and the total energy area. The R-square of the calibration curve is better than 94% and the maximum error of the yield test is 5.21%, demonstrating that it is feasible to measure the yield of D-T neutron source by oxygen prompt gamma rays. Additionally, the results meet the requirements for field determination of the conventional D-T neutron source yield.

Pulsed-laser-diode Intermittently Pumped 2-㎛ Acousto-optic Q-switched Tm:LuAG Laser

  • Wen, Ya;Jiang, Yan;Zheng, Hao;Zhang, Hongliang;Wang, Chao;Wu, Chunting;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.238-246
    • /
    • 2020
  • The heat distribution in crystals in a 2-㎛ acousto-optic Q-switched Tm:LuAG laser pumped by pulsed-laser-diode (pulsed-LD) intermittent-pumping technology was analyzed using COMSOL software. The thermal lensing effect of the Tm:LuAG crystal can be mitigated by pulsed-LD intermittent-pumping techniques. An experimental setup using this kind of approach achieved maximum output energy of 8.31 mJ, minimum pulse width of 101.9 ns, and highest peak power of 81.55 kW, reached at a Q-switched repetition rate of 200 Hz. It offers significant improvement of performance of the output laser beam, compared to pulsed-LD double-ended pumping technology at the same repetition rate.