• Title/Summary/Keyword: Austempered Ductile Iron

Search Result 73, Processing Time 0.028 seconds

Effect of Fully and Semi Austempering Treament on the Fatigue Properties of Ductile Cast Iron (완전 및 부분 오스템퍼링 처리가 구상흑연주철의 피로특성에 미치는 영향)

  • Lim Bok-kyu;Hwang Jung-gak;Kim Dong-Youl;Kim Min-gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.462-469
    • /
    • 2005
  • Single phase bainite structure which is obtained by the conventional austempering treatment reduces the ductility of ductile cast iron. Because of the reduction of ductility it is possible to worsen the fatigue properties. Therefore, semi austempered ductile iron which is treated from ${\alpha}+{\gamma}$ is prepared to investigate the static strength and fatigue properties in comparison with fully austempered ductile iron (is treated from ${\gamma}$). In spite of semi austempered ductile iron shows the $86{\%}$ increase of ductility. Also, semi austempered ductile iron shows the higher fatigue limit and lower fatigue crack growth rate as compared with fully austempered ductile iron. By the fractographical analysis, it is revealed that the ferrite obtained by semi austempering process brings about the plastic deformation(ductile striation) of crack tip and gives the prior path of crack propagation. The relatively low crack growth rate in semi austempered specimen is caused by above fractographical reasons.

A Study on the Artificial Defect Sensitivity of Fatigue Limit in Austempered Ductile Iron (오스템퍼링처리한 구상흑연주철에서 인공결함에 대한 피로한도 민감도에 관한 연구)

  • Kim, M.G.;Kim, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.3
    • /
    • pp.215-220
    • /
    • 1999
  • Rotary bending fatigue tests were carried out to investigate the artificial defect sensitivity of fatigue limit in annealed and austempered ductile irons. Artificial defect(hole, diameter${\leq}0.4mm$) machined on specimen surface did not bring about an obvious reduction of fatigue limit in austempered ductile iron as compared with annealed. As a result of investigation on $\sqrt{area}$ c which is the critical artificial defect size. $\sqrt{area}$ c of austempered ductile iron is larger than that of annealed. This means that the crack initiation at artificial defect in austempered ductile iron is more difficult in comparison with annealed. In case that the $\sqrt{area}$ c of artificial defect and graphite nodule are same, the rate of crack initiation for graphite nodule is higher than that of artificial defect.

  • PDF

A Study on the Governing Factor of Fatigue Limit in Austempered Ductile Iron (오스템퍼링 구상흑연주철의 피로한도 지배인자에 관한 연구)

  • 정회원;김진학
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.221-229
    • /
    • 1999
  • We examined the governing factors of fatigue limit in annealed and austempered ductile iron specimens machined micro hole(dia.<0.4mm) in rotary bending fatigue test. Also, the quantitative relationship between fatigue limit and maximum defect size in specimens was investigated. Artificial defect(micro-pit type, dia.<0.4mm) on specimen surface did not bring about an obvious reduction of fatigue limit in austempered ductile iton(ADI) as compared with annealed ductile iron. According to the investigation of ${\sqrt{area}}_c$ which is the critical defect size to crack initiation at artificial defect, ${\sqrt{area}}_c$ of ADI was larger than that of annealed ductile iron. This shows that the situation of crack initiation at artificial defect in ADI is more difficult in comparison with annealed ductile iron. Maximum defect size is one of the important parameters to predict fatigue limit. And, the quantitative relationship, between the fatigue limit ${\sigma}_{\omega}$ and the maximum defect size ${\sqrt{area}}_{max}$ can be expressed to ${\sigma}_{\omega}^n{\cdot}{\sqrt{area}}_{max}=C_2$ where, $C_2$ are constant. Moreover, it is possible to explain the difference in fatigue limit between, austempered and annealed ductile iron by introducing the parameter ${\delta}(=N_{sg}/N_{total})$in a plain spectimen.

  • PDF

Influence of Artificial Defect on Fatigue Limit in Austempered Ductile Iron (오스템퍼링처리한 구상흑연주철의 피로한도에 미치는 인공결함의 영향)

  • Kim, Min-Geon;Kim, Jin-Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.1922-1928
    • /
    • 1999
  • Rotary bending fatigue tests were carried out to investigate the influence of artificial defects on fatigue limit in annealed and austempered ductile iron. Obtained main results are as follows : (1) Artificial defect(micro hole type, dia.<0.4 mm) on specimen surface did not bring about a obvious reduction of fatigue limit in austempered ductile iron(ADI) as compared with annealed ductile iron. (2) According to the investigation of $\sqrt{area}_c$ which is the critical defect size to crack initiation at artificial defect, $\sqrt{area}_c$ of ADI is larger than that of annealed ductile iron. This shows that the situation of crack initiation at artificial defect in ADI is more difficult in comparison with annealed ductile iron. (3) One of the reasons for the low rate of crack initiation from artificial defect in ADI is that the resistance of matrix to crack initiation is higher than that of annealed ductile iron. (4) In case that the $\sqrt{area}$ of artificial defect and graphite nodule is the same, the rate of crack initiation from graphite nodule is higher than that from artificial defect. This reason is that the serious ruggedness around graphite nodule is formed by austempering treatment.

A Study on the Mechanical Properties and Fatigue Limit of the Austenitizing Treatment Conditions in Austempered Ductile Iron (오스템퍼링처리한 구상흑연주철의 오스테나이트화 조건에 따른 기계적 성질 및 피로한도에 관한 연구)

  • Kim, Min-Gun;Lim, Bok-Kyu
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.3-8
    • /
    • 2004
  • This study was performed to investigate the effect of two step austenitized treatment on the mechanical properties and fracture characteristic of the ductile cast iron and austempered ductile cast iron(ADI). The obtained results of this study were as follows. The matrix structures of specimens were changed differently by austenitizing heat treatment. Microstructure of austempered ductile cast iron obtained by two step austenitized treatment was bainitic ferrite and retained austenite. With two step austenitized treatment, vield strength, tensile strength and hardness decreased, while the elongation increased.

  • PDF

Effects of Molybdenum on the Microstructure of Austempered Ductile Iron (오스템퍼드 구상흑연주철의 미세조직에 미치는 Mo의 영향)

  • Lee, Kil-Hong;Park, Yun-Woo
    • Journal of Korea Foundry Society
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 1994
  • Mechanical properties of austempered ductile iron can be guaranteed if a good knowledge of its metallugical structure is obtained. In this paper, the effects of small Mo additions to austempered ductile iron on its metallurgical structures as a function of section size are examined. From the results, it is found that ${\gamma}-pool$ region and segregation of Mo in ${\gamma}-pool$ region are increased with increase in the section size.

  • PDF

Effects of Alloying Elements on the Mechniacal Properties of Hardened and Austempered 3.60%C-2.50wt%Si Ductile Cast Irons (3.60wt%C-2.50wt%Si 구상흑연주철의 경화 및 오스템퍼링 처리시 기계적 성질에 미치는 합금 원소의 영향)

  • Park, Jung-Jee;Seo, Gap-Sung;Kwon, Hae-Wook
    • Journal of Korea Foundry Society
    • /
    • v.28 no.6
    • /
    • pp.273-281
    • /
    • 2008
  • Effects of alloying elements on the mechanical properties of hardened and austempered 3.60wt%C - 2.50wt%C ductile cast iron were investigated. Strength and hardness were increased and ductility was decreased as the amount of alloying element increased. The increasing effect of copper addition on the strength was the most pronounced. The strength and hardness were greatly increased and ductility was decreased by hardening. The effect of alloying element on the mechanical properties of the hardened ductile cast iron was not so pronounced due to the high contents of C and Si. The strength and hardness of austempered ductile cast iron were greatly increased, meanwhile the difference of strength from that of hardened one was not so big. The ductility of the former was higher than that of the latter. The strength and ductility of austempered ductile cast iron with 0.25%Mn were the maximum of all Mn added ones. The maximum strength of that was obtained with the addition of 0.80wt%Cu or 2.00wt%Ni along with this amount of Mn added.

The Study on the Strength and Toughness of Austempered Ductile Cast Iron (오스템퍼 처리(處理)한 구상흑연주철(球狀黑鉛鑄鐵)의 강인화(强靭化)에 관(關)한 연구(硏究)(1))

  • Lee, Young-Kye;Kim, Sug-Won;Kim, Dong-Keon;Lee, Bang-Sik
    • Journal of Korea Foundry Society
    • /
    • v.10 no.2
    • /
    • pp.144-153
    • /
    • 1990
  • Ductile cast iron has good ductility and toughness, for the graphite morphology is spheroidal. It has been reported that the strengthening and toughening of the ductile cast iron was resulted from the modification of matrix structure by the heat treatment or the addition of alloying elements. In this study, effects of various special heat treatments (cyclic heat treatment and intermediate heat treatment) and Ni addition on the toughness and strength of the austempered ductile cast iron were studied. The results obtained from this study were as follows : 1. The amount of fine pearlite was increased with the Ni content and the number of cycle in cyclic heat treatment. 2. When the specimens treated and not by special heat treatment at 820 was austempered, in the former the austenite was formed on grain boundary entirely, but in the latter on grain boundary partially. 3. The impact energy was decreased with the Ni content, because the coarisen austenite pools formed with the Ni content was transformed into martensite during quenching. 4. The mechanical properties of austempered ductile cast iron containing 2%Ni treated cyclic heat treatment(5 cycles)was very excellent in handness 99(HRB), impact energy 12(kg-m) maximum fracture load 1500(kg-f).

  • PDF

The Effects of Se, CaCo and CaO Addition on the 1st Stage Graphitization of Malleable Cast Iron (오스템퍼 처리한 구상흑연주철의 강인성에 미치는 전조직의 영향)

  • Kim, Sug-Won
    • Journal of Korea Foundry Society
    • /
    • v.6 no.4
    • /
    • pp.290-297
    • /
    • 1986
  • Austempered ductile cast iron has been well known for their good toughness and strength. Generally these properties were improved by the various heat treatments and alloying elements. In this study, the effects of prior heat treatment history(near ferrite, near pearlite, near martensite) on the toughness and strength of the austempered ductile cast iron were studied experimentally and theoretically. All of the test specimens was austenitized at $900^{\circ}C$ for 1 h and austempered at $300^{\circ}C$, $350^{\circ}C$, $400^{\circ}C$, $450^{\circ}C$, respectively. The prior structure of near martensite in austempered ductile cast iron was not good in term of toughness and strength because the carbon content was apt to high in austenite during ausnitizing. It was found, on the other hand, that the ferrite matrix as prior structure had good combination of toughness and strenght. The best tensile strength and good toughness were obtained at $300^{\circ}C$, austemper in the prior structure of near ferrite, while $400^{\circ}C$ austemper in that of near pearlite and martensite.

  • PDF