• Title/Summary/Keyword: Average image difference

Search Result 430, Processing Time 0.035 seconds

An Implementation of Gaze Direction Recognition System using Difference Image Entropy (차영상 엔트로피를 이용한 시선 인식 시스템의 구현)

  • Lee, Kue-Bum;Chung, Dong-Keun;Hong, Kwang-Seok
    • The KIPS Transactions:PartB
    • /
    • v.16B no.2
    • /
    • pp.93-100
    • /
    • 2009
  • In this paper, we propose a Difference Image Entropy based gaze direction recognition system. The Difference Image Entropy is computed by histogram levels using the acquired difference image of current image and reference images or average images that have peak positions from $-255{\sim}+255$ to prevent information omission. There are two methods about the Difference Image Entropy based gaze direction. 1) The first method is to compute the Difference Image Entropy between an input image and average images of 45 images in each location of gaze, and to recognize the directions of user's gaze. 2) The second method is to compute the Difference Image Entropy between an input image and each 45 reference images, and to recognize the directions of user's gaze. The reference image is created by average image of 45 images in each location of gaze after receiving images of 4 directions. In order to evaluate the performance of the proposed system, we conduct comparison experiment with PCA based gaze direction system. The directions of recognition left-top, right-top, left-bottom, right-bottom, and we make an experiment on that, as changing the part of recognition about 45 reference images or average image. The experimental result shows that the recognition rate of Difference Image Entropy is 97.00% and PCA is 95.50%, so the recognition rate of Difference Image Entropy based system is 1.50% higher than PCA based system.

The Relationship between Nursing College Student's Major Satisfaction, Adjustment to College Life and Nurse's Image Nursing Students before Clinical Practical Education (임상실습교육 전 간호대학생의 전공만족도, 대학생활 적응 및 간호사 이미지의 관계)

  • Kim, Mi-Young;Park, Hae-Jin
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.251-259
    • /
    • 2022
  • Purpose : This study was conducted to check the effect on nursing college students' major satisfaction, adjustment to college life and nurse's image nursing students before clinical practical education. Methods : The study surveyed 209 college students majoring in nursing science in the city of B for the period of April through May 2022. The collected data were analyzed using SPSS/WIN 22.0 to determine the frequency, percentage ratio, average, and standard deviation. Statistical analyses included the t-test, analysis of variance, pearson's correlation coefficients. Results : As a result of this study, the average degree of satisfaction with majors was 3.88±.50, the average of college life adaptation was 3.26±.47, and the average of the nurse image was 3.90±.51. The major satisfaction according to the general characteristics of the study subjects showed a statistically significant difference in the motive for choosing a department (F=3.70, p=.003) and the thought of a nursing job (F=2.95, p=.004). The adjustment to college life according to the general characteristics of the study subjects showed a statistically significant difference in grade (F=3.50, p=.001), department selection motivation (F=2.69, p=.022) showed a statistically significant difference. The nurse image showed a statistically significant difference in residence type (F=6.00, p=.001) and nursing job thinking (F=2.11, p=.036). The correlation between the variables of the study subjects showed that major satisfaction was found to have a positive correlation with adjustment college life (r=.51, p<.001) and nurse image (r=.54, p<.001). It was found that adjustment college life had a positive correlation with the nurse image (r=.32, p<.001). Conclusion : The higher the degree of satisfaction with the major of nursing students prior to clinical practice education, the higher the degree of adaptation to college life. It is need to intervention studies that can improve the image of positive nursing.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Eyebrow Make-up Type Using an Average rate Sensitivity Image for the Difference of Perceived Sexiness (평균변화율을 활용한 눈썹 메이크업 유형별 섹시미 감성이미지 차이)

  • Kim, Jinkyeong;Park, Jeongshin
    • Journal of Fashion Business
    • /
    • v.19 no.5
    • /
    • pp.34-47
    • /
    • 2015
  • Sexiness is the image of a person who attracts attention regardless of his/her age, and today's society has created a more positive impression by transforming the image into something others consider even more attractive. Consequently, we begin to take interest in makeup, - a means of portraying a good impression. Eyebrow makeup in particular, being at the center of the determining factor of a good facial image, can be thought of as the makeup that can most effectively transform one's image. The purpose of this study was to analyze the difference in perceived sexiness depending on the general perception of eyebrow makeup. This study produced an eyebrow stimulus that applied the average rate of change in an image transformation of different eyebrows in order to raise the objective credibility of the sensibility evaluation so it could determine the figure of influence that eyebrows had on facial impressions. The research results showed that the majority of female university students believed that eyebrows were an effective means of expression in changing facial images and attributed a higher mature and sexy image if the average ratio of change was higher. The study, could also identify that a sexy image was perceived when the average rate of change was between 0.39~0.44. In addition, when the gradient of the shape of the viewers' own eyebrows was low, it could be verified that they perceived an image to be sexy from seeing eyebrows with a relatively high gradient.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

The Usefulness Analysis of Applying Dose Mode in Mammography Women of Childbearing Age (가임기 여성의 유방촬영에서 Dose mode 적용의 유용성 분석)

  • Lee, So-Ra;Son, Soon-Lyong;Chung, Jae-Yoen;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.19-23
    • /
    • 2013
  • Purpose : Automatic exposure system(AOP mode) in DR Mammography of the STD and DOSE apply to women of childbearing age, the average glandular dose(AGD) and image quality by comparing was to demonstrate the usefulness of DOSE. Materials and Methods : Of the under 40 age 108 patients who visit to our hospital and examined STD and DOSE mammography from January 2008 to July 2013. AGD was obtained by DICOM header information provided by GE Senographe DS. STD and DOSE images were evaluated with obtained patients, Image J program was compared by calculating the SNR. Results : The average AGD of DOSE mode was 0.99mGy, and which decreased by 19% comparing to that of STD mode which was 1.18mGy. The two the average AGDs indicated statistically significant difference(p< .01). The average SNR of STD was 40.26, DOSE displayed, and to 39.68 in, there was no statistical significance. Results : The average AGD using DOSE mode which is one of DR mammography AOP modes decreased by comparing to that of STD mode showing no difference in image quality. The use of DOSE is considered to be useful.

  • PDF

Edge Enhanced Error Diffusion based on Local Average of Original Image (원영상의 로컬 평균을 이용한 경계강조 오차확산법)

  • Kang, Tae-Ha;Hwang, Byong-Won
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.8
    • /
    • pp.2565-2574
    • /
    • 2000
  • The error diffusion method is good for reproducing continuous image to binary image. However the reproduction of edge characteristic is weak in power spectrum analysis of display error. In this paper. we present an edge-enhanced error-diffusion method which include pre-processing algorithm for edge characteristic enhancement. Pre-processing algorithm consists of the difference value between current pixel and local average of original image and weighting function of pre-filter. First. it is obtained the difference value between current pixel and the local average of peripheral pixels(5x5) in original image. Second, weighting function of pre-filter is composed by function including absolute value and sign of difference value. The improved Error diffusion algorithm using pre-processing algorithm, present a good result visually which edge characteristic is enhanced. The performance of the proposed algorithm is compared with that of the conventional edge-enhanced error diffusion by measuring the RAPSD of display error, the egde correlation and the local average accordance.

  • PDF

Vehicle Face Re-identification Based on Nonnegative Matrix Factorization with Time Difference Constraint

  • Ma, Na;Wen, Tingxin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.6
    • /
    • pp.2098-2114
    • /
    • 2021
  • Light intensity variation is one of the key factors which affect the accuracy of vehicle face re-identification, so in order to improve the robustness of vehicle face features to light intensity variation, a Nonnegative Matrix Factorization model with the constraint of image acquisition time difference is proposed. First, the original features vectors of all pairs of positive samples which are used for training are placed in two original feature matrices respectively, where the same columns of the two matrices represent the same vehicle; Then, the new features obtained after decomposition are divided into stable and variable features proportionally, where the constraints of intra-class similarity and inter-class difference are imposed on the stable feature, and the constraint of image acquisition time difference is imposed on the variable feature; At last, vehicle face matching is achieved through calculating the cosine distance of stable features. Experimental results show that the average False Reject Rate and the average False Accept Rate of the proposed algorithm can be reduced to 0.14 and 0.11 respectively on five different datasets, and even sometimes under the large difference of light intensities, the vehicle face image can be still recognized accurately, which verifies that the extracted features have good robustness to light variation.

Perceptional Difference of Sexual Image and Sexual Role between Male and Female Students in University, Korea (남녀 대학생의 성 이미지와 성 역할 인식의 차이)

  • Yang, Soon-Ok;Jeong, Geum-Hee
    • Women's Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.289-300
    • /
    • 2002
  • The purpose of this study was to identify the perceptional difference of sexual image and sexual role between male and female students at the university level.. Questionnaires were collected from 418 students of H University in Kangwon-do, Korea from September to December 1999. The research tools were Sexual Image(Joo,1996, Cronbach's $\alpha$=.83) and Sexual Role (Chang,1989, Cronbach's $\alpha$=.93). Data were analyzed by SPSS-PC. The results of this study were as follows: According to factors of sexual image, the average score of sexual attitude was 3.06, that of sexual evaluation was 2.41, and that of sexual curiosity was 2.18, therefore university students had a high degree of curiosity but also had a relatively more exclusive image related to sexuality; there was a significant difference in sexual image between male and female students (t=10.99, p=0.010), male students were perceived to have a higher sexual curiosity and more positive sexual image than female students; the average score of sexual role was 2.21, that appeared to be a moderately progressive tendency; there was a significant difference in sexual role between male and female students (t=260.46, p=0.000), female students were apt to be more progressive in sexual role than male students. According to the above results, curriculum development and the application of at university would be necessary to develop and apply some liberal courses and workshop programs so that students and professors could prepare to identify ideal sexual roles and sexual images.

  • PDF