• Title/Summary/Keyword: Baby Monitoring System

Search Result 12, Processing Time 0.021 seconds

The Remote Monitoring System for Baby using by PDA (PDA를 이용한 유아 원격 감시 시스템)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1779-1782
    • /
    • 2009
  • The developed system is captured by RS-232 telecommunication receiving data (temperature and humidity of each incubator) through radio frequency sensor network system and is made by monitoring system for one person collecting each channel data. This monitoring system is capable of monitoring not only PDA through TCP/IP telecommunication but also personal computer. This system is actively application on telecommunication function of LabVIEW and PDA module and is considerably saved in processing time than using in other tools.

Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress (도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계)

  • Yang, Seong-Soo;Cho, Sung-Pil;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

Design and Implementation of a Digital Control Unit for an Oxygenaire Servo Baby Incubator

  • Zahran, Mohamed;Salem, Mahmoud;Attia, Yousry;Eliwa, Aref
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • This paper introduces a design and implementation of a digital control unit for an Oxygenaire Servo Baby Incubator. The control unit is designed and implemented according to international standards. The control unit is based on an AVR Atmel microcontroller unit. It is built for monitoring and control and displays the three main temperature values: set point temperature, baby skin temperature and air temperature. User friendly software is implemented. The implemented control unit was tested in the laboratory as well as in the field. The control unit is sensitive to change of $0.1^{\circ}C$. At startup, based on a unique control strategy, the incubator reaches its steady state in about 14 minutes. The system schematic diagrams are shown in the paper. Also, programs flow charts are presented. The control unit was designed and implemented based on a contract between the Electronics Research Institute (ERI) and ENGIMED Company. The authors would like to thank ERI and ENGIMED for introducing all required finance and shoring to complete this work.

Alarm System for Sudden Infant Death using Bio-Signals (생체 신호를 활용한 영아 돌연사 알람 시스템)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.197-202
    • /
    • 2016
  • In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.

The Development of Monitoring System for Baby (신생아 감시 시스템 개발)

  • Lee, Jeong-Ick
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.681-683
    • /
    • 2010
  • 본 연구를 통해 개발된 적외선 네트워크 시스템은 RS-232 원거리 통신 데이터 즉, 각 인큐베이터의 온도 및 습도의 획득이 가능하다는 점이다. 또한, 본 시스템은 수집된 각 유아들의 채널 데이터를 얻기 위해 감시시스템이 만들어지도록 설계되었다. 이 감시시스템은 TCP/IP 통신을 통한 PDA 모니터링 뿐만이 아니라 개인의 PC로도 동작이 가능하도록 설계되어 있다. 이 시스템은 LabVIEW 및 PDA 모듈의 원거리 무선 기능 위에서 능동적으로 동작되며 어느 다른 툴보다 처리시간이 상당히 짧다.

  • PDF

Development of Non-contact Home Monitoring System for Infant Respiration to Prevent SIDS (영아 돌연사 방지를 위한 비접촉 방식의 가정용 영아 호흡 감시 시스템 개발)

  • Heo, Il-Kang;Myoung, Hyoun-Seok;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.48-53
    • /
    • 2015
  • Sudden infant death syndrome(SIDS) continues to be general cause of infant death. Also, apnea is supposed to be one of the main risk factor of SIDS. Therefore, Infant's respiratory monitoring and real-time apnea detection is very important to prevent SIDS. In this study, we proposed a non-contact home monitoring system for infant's respiration using Doppler radar in order to prevent SIDS. The respiration data were acquired from a commercialized baby simulator(Simbaby$^{TM}$) using a Doppler radar. To evaluate a performance of the proposed system, the simulator was placed in a supine and prone position and the chest belt was used simultaneously as a reference signal. As a result, correlation coefficients between respiration rates of Doppler radar and the chest belt in each position were 0.95(p < 0.001) and 0.98(p < 0.001), respectively. The averages of difference were $-0.29{\pm}5.21(mean{\pm}1.96{\cdot}$ standard deviation) in supine and $-0.12{\pm}3.05$ in prone from Bland-Altman analysis. The results indicated an excellent performance in detecting apnea with a sensitivity of 100% and a positive predictive value of 100% in each posture respectively. These results demonstrated that a proposed Doppler radar system is suitable for non-contact respiratory monitoring in order to prevent SIDS of infant.

Development of a LonRF Intelligent Device-based Ubiquitous Home Network Testbed (LonRF 지능형 디바이스 기반의 유비쿼터스 홈네트워크 테스트베드 개발)

  • 이병복;박애순;김대식;노광현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.566-573
    • /
    • 2004
  • This paper describes the ubiquitous home network (uHome-net) testbed and LonRF intelligent devices based on LonWorks technology. These devices consist of Neuron Chip, RF transceiver, sensor, and other peripheral components. Using LonRF devices, a home control network can be simplified and most devices can be operated on LonWorks control network. Also, Indoor Positioning System (IPS) that can serve various location based services was implemented in uHome-net. Smart Badge of IPS, that is a special LonRF device, can measure the 3D location of objects in the indoor environment. In the uHome-net testbed, remote control service, cooking help service, wireless remote metering service, baby monitoring service and security & fire prevention service were realized. This research shows the vision of the ubiquitous home network that will be emerged in the near future.

Design of Apnea Monitoring System by impedance technique (임피던스를 이용한 무호흡감시 시스템 설계)

  • Park, S.B.;Jeon, D.K.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.232-235
    • /
    • 1997
  • Apnea refers to episode of apnea (or not breathing) lasting more than 10 seconds that occur while sleeping. These episodes, whitch can occur hundreds of times per night, may transiently awaken resulting in fragmentation of sleep. Although the precise cause of Sudden Infant Death Syndrome(SIDS) are still unclear, there is evidence to suggest that hypoxaemia may be a contributory actor. Transcutaneous oxygen monitor can be used, but it is very difficult to use or baby stayed at home. In this reason, monitors whitch is easy or deal with are reqiured. In 1972, Steinschieder reported that two of the five infants noted to have apnea lasting or more than 20 seconds later died of SIDS episode, he also suggested that home monitoring or neonates should be used or managing apnea at home. Transthoracic electrical impedance technique is used or acquiring respiration waveform and detecting episode of apnea state. Transthoracic electrical impedance measurements have been made from the human trunk over the frequency range 9.6KHz to 614KHz. We conclude that application of impedance technique or detecting apnea state is proper or neonates.

  • PDF

Implementation of a Baby Monitoring System for Parents (부모를 위한 아기 돌봄이 시스템 구현)

  • Park, Jun-Wan;Hong, Yoon-Ki;Song, Bo-Jeong;Ha, Na-Ri;Kang, Seok-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.83-86
    • /
    • 2011
  • 본 논문에서는 잠을 자주 깨는 아기를 키우는 부모의 어려움을 덜어주기 위한 IT 융합 시스템을 제안한다. 제안된 시스템은 필요 시 요람을 자동으로 움직여주는 기능 및 아기의 상태, 대소변 유무를 스마트폰을 통해 원격으로 전송해 주는 기능을 포함하고 있다. 제안된 시스템의 요람 내부에 설치된 소음센서가 아기 울음 소리를 인식하면, 그 신호가 중앙 제어 부로 보내지고 요람이 적당한 강도로 움직이기 시작한다. 동시에 낙수음(落水音)을 아기에게 들려줌으로써 엄마 뱃속에 있을 때와 같은 편안함을 준다. 또한, 요람에 장착된 태블릿 카메라를 통해 원격으로 아기의 현재 상태를 확인 할 수 있다. 이러한 시스템은 부모가 아기를 요람에 두고서도 스마트폰을 통해 아기의 상태를 항시 체크하면서 다른 일을 할 수 있도록 하여 생산성을 높이는 효과도 있을 것으로 기대된다.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.