• Title/Summary/Keyword: Base-Excited Vibration

Search Result 29, Processing Time 0.041 seconds

Vibration Analysis of an Amplitude Proportional Friction Damper System (변위비례식 마찰댐퍼 시스템의 진동해석)

  • 박동훈;최명진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.171-179
    • /
    • 2003
  • An Amplitude Proportional Friction Damper (APFD) is considered in order to improve the characteristics of Coulomb friction damper. The frictional force is proportional to the amplitude in APFD system and the system is non-linear as is Coulomb damper system. A free vibration analysis on the 1-DOF system has made to demonstrate the characteristics of the APFD system. The results show that APFD system has similar damping characteristics to the viscous damper. Also, the solution for the response of a base-excited system with APFD is developed through the application of a Fourier series to represent the frictional force of APFD. It is assumed that no stick-slips occur during any portion of the steady-state oscillation.

A State-Space Transient Response Analysis of Rotor-Bearing System with Base Excitation (기초가진 로터-베어링 시스템의 상태공간 과도응답해석)

  • 이안성;김병옥;김영철;김영춘
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.669-674
    • /
    • 2004
  • In this study, the analytical method to evaluate the response of rotor-bearing system subjected to base excitation was presented. The equations of motion contain speed dependent gyroscopic terms, base rotation dependent parametric terms and several forcing function terms which depend on linear accelerations, rotational accelerations and a combination of linear and rotational combination. The study of rotor-bearing system excited by its base motion is not only able to predict the rotational performance, but provides the fundamental data for vibration isolation. In order to illustrate transient response, transient response analysis of a practical application sample were performed. The transient response was carried out for the given base excitation by using the state-space Newmark method that incorporates the average velocity concept.

  • PDF

Usage of Dynamic Vibration Absorbers for a Beam Subjected to Moving Forces and for a System Mounted on a Moving Base (이동하중을 받는 보와 가동 기초 위에 설치된 계에의 동흡진기의 이용)

  • Lee, Gun-Myung;Byun, Jai-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.27-34
    • /
    • 2015
  • Dynamic vibration absorbers are widely used in machinery, buildings, and structures, including bridges. Two cases of their usage are considered in this paper. One is a simply supported beam subjected to either a moving force or a sequence of moving forces, which simulates a train-bridge interaction problem. The other is a case where a primary system is mounted on a base that is not grounded and is excited by an external force. The conditions that the dynamic vibration absorbers must meet in these cases are found and compared to those for usual cases where bases of primary systems are grounded.

Nonplanar Nonlinear Phenomenon of Base Harmonic Excited Circular Cantilever Beam (기초조화가진을 받는 원형 외팔보의 비평면 비선형 현상)

  • Kim, Myoung-Gu;Park, Chul-Hui;Cho, Chong-Du;Piao, Chang-Hao
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.690-695
    • /
    • 2005
  • Flexible circular cantilever beams when excited externally introduce a lot of dynamic characteristics. The non-linear elements that these flexible beams develop include non-linearity due to inertia terms, spring, and damping. They show different characteristics of motion from each other. In the modes of lower order, the non-linearity due to spring is prevalent, while the non-linearity due to inertia Is prevalent in the modes of higher order. To analyze these effects the non-linear phenomena are analyzed experimentally. When the response characteristics of non-linear vibration are analyzed using autospectrum, it is possible to analyze the subharmonic and superharmonic mot ion by comparison. The phase change is analyzed using the method of phase portrait and the non-linear characteristics of response characteristics that are developed in flexible structures can be predicted and applied to the stage of design.

  • PDF

Vibro-acoustic Analysis for Predicting the Noise of HDD (하드디스크 드라이브 소음 예측을 위한 진동 음향 연계 해석)

  • 이상희;고상철;김준태;강성우;한윤식;황태연
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.103-108
    • /
    • 2001
  • The structure of hard disk drive(HDD) is excited by dynamic motion of a disk-spindle motor, and it makes sound noise. Therefore, the cover and the base of HDD should be designed to reduce noise and vibration induced by spindle motor. The prediction technique of sound pressure level(SPL) of a given structural shape enables us to design a cover and a base with much less vibration and noise. In this paper, we measured the force of disk-spindle motor and predicted SPL from HDD by computational simulation. To get a SPL of HDD by computational simulation, modal analysis and forced vibration analysis were performed with ANSYS, and sound radiation was computed using SYSNOISE. The calculated results were compared with experimental results and a good agreement was obtained. With this computer simulation procedure and design of experiment(DOE), optimal thickness of noise barrier and damper was calculated.

  • PDF

The design of the robust hybrid controller for the construction using an active dynamic vibration absorber

  • Lee, Sang-Kyu;Lee, Jin-Ho;Hwang, I-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.75.4-75
    • /
    • 2001
  • This paper designs the robust hybrid controller for the multi degree-of-freedom system having uncertainty caused by modeling error and disturbances. The controlled plant is the construction which has an active dynamic vibration absorber on the top and is excited by the El Centre earthquake at the base. The active controller designed by the LQR(Linear Quadratic Regulator) and H-infinity control theory. The robustness of the hybrid H$\infty$ controller is compared with that of the hybrid LQ controller from computer simulation.

  • PDF

Dynamic characteristics of structures with multiple tuned mass dampers

  • Jangid, R.S.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.5
    • /
    • pp.497-509
    • /
    • 1995
  • Effectiveness of multiple tuned mass dampers (MTMD) in suppressing the dynamic response of base excited structure for first mode vibration is investigated. The effectiveness of the MTMD is expressed by the ratio of the root mean square (RMS) displacement of the structure with MTMD to corresponding displacement without MTMD. The frequency content of base excitation is modelled as a broad-band stationary random process. The MTMD's with uniformly distributed natural frequencies are considered for this purpose. A parametric study is conducted to investigate the fundamental characteristics of the MTMD's and the effect of important parameters on the effectiveness of the MTMD's. The parameters include: the fundamental characteristics of the MTMD system such as damping, mass ratio, total number of MTMD, tuning frequency ratio, frequency spacing of the dampers and frequency content of the base excitation. It has been shown that MTMD can be more effective and more robust than a single TMD with equal mass and damping ratio.

Dynamic characteristic for vibration mount of MG-Set (전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명)

  • Yoo, Musang;Oh, Kyonghan;Joo, Ingouk;Kim, Hyojin;Roh, Cheolwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

Sliding Mode Control of an Active Magnetic Bearing System (능동자기베어링계의 슬라이딩모드 제어)

  • 강민식
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.439-448
    • /
    • 2004
  • Magnetic bearing is an attractive device in precision engineering field because of its non-contacting nature and controllability of its dynamic characteristics. This paper provides a method of designing a sliding mode control for an active magnetic hearing(AMB) system which is used to support the elevation axis of a target tracking sight instead of mechanical bearings to eliminate the effect of mechanical friction. In such system, the axis should be levitated and supported within a predetermined air gap while AMB is excited by base motion. Experimental results showed that the sliding mode control is effective in disturbance rejection than conventional PID-control without any additive measurements.

Robust Vibration Control for a Building with Parameter Uncertainty (파라미터 불확실성을 고려한 건물의 견실 진동 제어)

  • 최재원;김신종;이만형
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.575-583
    • /
    • 2000
  • In this paper, we design a vibration control system that includes a 3-D.O.F. mass-spring-damper structure for the analytical model of a building that is excited at the base of this structure by an external dynamic force, and one Active Mass Damper(AMD) on the top of this structure to generate control forces fro attenuation of the structural response. Two robust controllers based on $\mu$-synthesis and H$\infty$ optimal control are designed for the structural system to show that the performance of a control system can be degraded by some parameter uncertainties such as mass, stiffness coefficients, and/or damping coefficients. The performance of the two controllers are compared in terms of nominal performance, robust stability and robust performance by simulations.

  • PDF