Design of a Cascade Adaptive Filter for the Removal of Baseline Drift (기저선 변동 제거를 위한 종속 적응필터의 설계)

  • Park, Kwang-Li;Lee, Se-Jin;Lee, Kyoung-Joung;Yoon, Hyung-Ro
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.101-104
    • /
    • 1995
  • In this paper, we designed a cascade adaptive filter for elimination of the baseline drift and the distortion of the filtered signal. The cascade adaptive filter(CAF) consists of two filters. The first adaptive filter which has the cutoff frequency of 0.3Hz eliminate the noisy signal. The second adaptive filter remove the remnant baseline drift which is not eliminated by the first adaptive filter. Comparing the performance of the CAF with standard filter, recursive notch filter(RNF) and a adaptive impulse correlated filter(AICF), the CAF showed a higher performance in removal of the baseline drift than standard filler, and RNF. Also, considering the distortion of filtered signal, CAF is better than AICF and is comparable to the standard filter.

  • PDF

A study of estimation and removal of baseline drift for the automated diagnosis of electrocardiogram (심전도 자동 진단을 위한 기저선 동요 평가 및 제거에 관한 연구)

  • 권혁제;이명호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.99-106
    • /
    • 1996
  • Estimation and removal procedures for baseline drift have been developed using linear, cubic spline, and bilineared transformed high pass filter. Linear and cubic spline interpolation with the PQ and TP segmens, which are considered to be isoelectric, as fiducial points ahve been estimated respectively. For a quantitative validation of the estimation procedure, 4 ECGs with arfificial baseline drift were constructed and analyzed by mean square error calculations and amplitude histograms. Also real ECGs were analyzed in a test set of the CSE data set 3 and set 4. Baseline drift detecton rule were designed and new method for the decision of fiducial point were constructed to avoid distorting as the case of premature ventricular or atrial contraction. From these comparison, proposed cubic spline method with PQ and TP segment (CS_PQ & TP) emerged as the most efficient method.

  • PDF

Short term Sensor's Drift Compensation by using Three Drift Correction Techniques (세 가지 드리프트 보정 기법을 이용한 단기 센서 드리프트 보정)

  • Jeon, Jin-Young;Choi, Jang-Sik;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.291-296
    • /
    • 2016
  • The ideal chemical sensor must show the similar result under the same condition for accurate measurement of gases regardless of time. However, the actual responses of chemical sensors have been shown the lacks of repeatability and reproducibility because of the drift which has been caused by aging and pollution of the sensor and the environment change such as temperature and humidity. If the problems are not properly taken into considerations, the stability and reliability of the system using chemical sensors would be decreased. In this paper, we analyzed the sensor's drift and applied the three different compensation methods(DWT( Discrete Wavelets Transform), Baseline Manipulation, Internal Normalization) for reducing the effects of the drift in order to improve the stability and the reliability of short term of the chemical sensors. And in order to compare the results of the methods, the standard deviation was used as a criterion. The sensor drift was analyzed by a trend line graph. We applied the three methods to the successive data measured for three days and compared the results. As a result of comparison, the standard deviation of DWT showed lowest value. (Before compensation: 7.1219, DWT: 1.3644, Baseline Manipulation: 2.5209, Internal Normalization: 3.1425).

Removing Baseline Drift in ECG Signal using Morphology-pair Operation and median value (Morphology-pair 연산과 중간 값을 이용한 심전도 신호의 기저선 변동 잡음 제거)

  • Park, Kil-Houm;Kim, Jeong-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.107-117
    • /
    • 2014
  • This paper proposed the method of removing baseline drift by eliminating local maxima such as P, R, T-wave signal region and local minima Q, S-wave signal region. We applied morphology-pair operations improved from morphology operation to the ECG signal. To eliminate overshoot in the result of morphology-pair operation, we apply median value operation to the result of morphology-pair operation. We use MIT/BIH database to estimate the proposed algorithm. Experiment result show that proposed algorithm removing baseline drift effectively without orignal ECG signal distortion.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

Removing Baseline Drift from ECG Signal Using Smoothing Spline and Morphology Operation (평활화 스플라인 연산과 형태학 연산을 이용한 기저선 변동 잡음 제거)

  • Back, Seung-Gwan;Choi, Chang-Hoon;Kim, Jeong-Hong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.162-171
    • /
    • 2017
  • Low frequency noise components causes the baseline drift in the ECG signals. In this paper, a morphological operation and smoothing spline technique are used for ECG signal processing in order to accomplish baseline correction. Removing the baseline drift from ECG signal using morphology operation, the feature of original signal may be distorted. To resolve this distortion problem, we applied a smoothing spline operation after morphology operation. In order to compare with existing morphology operation method for baseline correction, we apply proposed method to ECG data in MIT/BIH database. Compared to other existing method, our proposed method achieved low data distortion on the original signal.

Baseline Drift Reduction and Suppression of Power Line Noises in ECG Signal by Designing Multirate Digital Filter (다중레이트 디지털 필터 설계 및 심전도 신호의 기저선 변동 및 전원 잡음 제거)

  • Kim, Jeong-Hwan;Kim, Hyun-Tae;Park, Sang-Eun;Lee, Jeong-Whan;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.551-558
    • /
    • 2014
  • Baseline drift reduction and removal of power line noises in electrocardiogram are often necessary to avoid the distortions in extracting the fiducial features. With this aim, the multirate digital filtering algorithm is suggested to design and implement Finite Impulse Response or Infinite Impulse Response Filter by changing the sampling rate with omitting or interpolating intermediate ECG data. After the experimental simulations performed, we can conclude the fact that we can suppress the baseline wander and power line disturbances in ECG signal with reducing the computational complexities in which we do not keep the original and high sampling frequency.

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

Phase and Amplitude Drift Research of Millimeter Wave Band Local Oscillator System

  • Lee, Chang-Hoon;Je, Do-Heung;Kim, Kwang-Dong;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • In this paper, we developed a local oscillator (LO) system of millimeter wave band receiver for radio astronomy observation. We measured the phase and amplitude drift stability of this LO system. The voltage control oscillator (VCO) of this LO system use the 3 mm band Gunn oscillator. We developed the digital phase locked loop (DPLL) module for the LO PLL function that can be computer-controlled. To verify the performance, we measured the output frequency/power and the phase/amplitude drift stability of the developed module and the commercial PLL module, respectively. We show the good performance of the LO system based on the developed PLL module from the measured data analysis. The test results and discussion will be useful tutorial reference to design the LO system for very long baseline interferometry (VLBI) receiver and single dish radio astronomy receiver at the 3 mm frequency band.

A Comparison of Representative Beat Extraction Algorithms in ECG (심전도 신호에서의 대표 비트 설정에 관한 알고리즘 비교)

  • 김동석;전대근;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.299-305
    • /
    • 1999
  • In thls paper, the representative beal textraction algorIthms for the diagnostic parameter extraction in noisy signal were compared. We used the avernge, median, mode, and trmmed mean to calculale the central tendency. In our experimenl, we have restricted to four kinds of noises -EMG noise, 60Hz powerline inlerference, ahrupl baseline shift, and baselme drift due to respimtion-which were commonly occurred in ECG mgnal, then we have calculated signal-to-noise ratios(SNRs) for the ECG corrupted with each noise and all noises together. As the result of this paper, we have proved that the average method has super lor performance than the others in the ECG corrupted wilh EMG noise. When the signal mcludes extreme value such as abrupt baseline shIft, the median, mode, trimmed mean methods have supenor performance in the SNR ratios. Especially when the ECG corrupted with baseline drift due to respirallon, the trimmed mean method was most efficient because ST level change was 0 V.

  • PDF