• Title/Summary/Keyword: Biceps brachii

Search Result 180, Processing Time 0.021 seconds

Ultrasonographic diagnosis of calcifying tendinopathy of the biceps brachii in a Doberman Pinscher dog: a case report

  • Han, Changhee;Kim, Ah Reum;Hwang, Gunha;Kim, Rakhoon;Go, Woohyun;Lee, Ji Yeong;Lee, Jongbong;An, Soyon;Hwang, Tae Sung;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.1
    • /
    • pp.6.1-6.4
    • /
    • 2022
  • A 10-year-old, spayed female, Doberman Pinscher dog presented with right forelimb lameness. On physical examination, painful reaction and crepitation were present at the right shoulder. Radiographic evaluation of the shoulder revealed nothing remarkable. On the ultrasonography of the right shoulder joint, 2 small echogenic masses accompanied by reverberation artifacts were observed in the right biceps tendon near its origin at the supraglenoid tuberosity. Based on these findings, we suspected biceps calcifying tendinopathy. Clinical signs resolved intermittently after administration of nonsteroidal anti-inflammatory drug. This study described the ultrasonographic findings of calcifying biceps brachii tendinopathy which is an unusual finding in dogs.

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.

Short-Term Results of Subpectoral Tenodesis of the Proximal Biceps Tendon Using by Interference Screw (간섭나사를 이용한 흉근하 상완 이두근 건 고정술의 단기 추시 결과)

  • Kim, Jeong-Woo;Kang, Hong-Je
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Purpose: Our purpose was to retrospectively analyze clinical results of subpectoral tenodesis of the proximal biceps tendon using an interference screw. Materials and Methods: We reviewed 23 cases of patients receiving tenodesis of the proximal biceps tendon between January 2008 and January 2009 for whom we had follow-up data for at least 1 year. Twenty-three cases were operated on using subpectoral tenodesis; 16 of these cases had a rotator cuff tear. The results were judged using a visual analog scale (VAS), ASES, tenderness on the biceps groove, fixation failure and the degree of deformity (BAD). Results: VAS and ASES scores were significantly improved in all patients by the time of the final observation. There were no significant complications or fixation failures. The patients without a tear of the rotator cuff had a better result than patients with a tear of the rotator cuff, but the difference between the two groups was not significant (p>0.05). Conclusion: In patients with pathology of the long head of the biceps brachii, benefits of subpectoral interference screw tenodesis include pain relief, maintenance of functional biceps, muscle strength, and cosmesis. Subpectoral biceps tenodesis using interference screw fixation appears to be a promising, reproducible, reliable technique for addressing anterior shoulder pain related to pathology of the long head of the biceps brachii.

Electromyographic Analysis of the Biceps Brachii during Provocative Tests (상완 이두 건 병변에 대한 유발 검사시의 근전도 분석)

  • Lee Young-Soo;Shin Dong-Rae;Cho Sang-Hyun;Nam Ki-Sun;Kim Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.170-177
    • /
    • 1999
  • The electromyographic activity of four muscles(biceps, supraspinatus, infraspinatus and subscapularis) was mea­sured from non-dominant shoulders of 12 volunteers by six different provocative test for the biceps pathology. The provocative tests were Speed, Yergason, Ludington, Heuter, O'Brien and the abduction-extension test. Each test was performed in a force of 30% of maximal voluntary contraction. The levels of activity of the biceps were higher than those of the other rotator cuff muscles only in Speed's test: 28% in the biceps, 26% in the infraspinatus, 25% in the supraspinatus and 21 % in the subscapularis. The levels of activity of the biceps as a percent of MMT(maximal manual test) were higher in Speed's(42%) and O'Brien's test with the arm supinatecl(42%). Speed's test can isolate the activity of biceps better than the other tests but it is a nonspecific test by which the biceps tendon was also activated within other rotator cuff muscles.

  • PDF

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Comparison of Ultrasonography on Both Sides of the Upper Extremity Muscle of Hemiplegic Patient (편마비환자 양측 상지근에 대한 초음파 영상 비교)

  • Seo, Sam-Ki;Lee, Jeong-Woo;Yoon, Se-Won
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2007
  • This study aims to comparison of ultrasonography on both sides of the upper arm of hemiplegic patient. The biceps brachii and deltoid muscle of ten subjects(4 men, 6 women) with stroke were scanned with ultrasonography at the muscle belly at rest at elbow angles of 90 deg. The echogenicity(densit, white area index; WAI) and muscle thickness of ultrasonography was examined using real-time B-mode ultrasonography with 7.5 MHz linear-array prob. In the biceps brachii muscle, MHz there were significant differences of thickness, density, and WAI between affected side and non-affected side. In the deltoid muscle, there were significant differences of thickness, density, and WAI between affected side and non-affected side. Both of the muscles, thickness of the affected side was thin than non-affected side and echogenicity(density, WAI) of the affected side was higher than non-affected side. This study showed that change of skeletal muscle architecture properties occurred in the upper arm of the affected side muscle of hemiplegic patient.

  • PDF

Characteristics of Median Frequency According to the Load During Fatiguing Isometric Exercise (등척성 운동시 운동강도에 따른 중앙주파수의 특성)

  • Lee, Su-Young;Shin, Hwa-Kyung;Cho, Sang-Hyun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.141-149
    • /
    • 2003
  • Median frequency can be regarded as a valid indicator of local muscle fatigue. As local muscle fatigue develops, the muscle fiber conduction velocity decreases, the fast twitch fibers are recruited less, and consequently the median frequency shifts toward the lower frequency area. The aim of this study was to test the characteristics of the median frequency according to exercise load (30% and 60% of MVC on the biceps brachii, 40% and 80% of MVC on the vastus lateralis) during the fatiguing isometric exercise. Thirteen healthy male volunteer students of Yonsei University were recruited. After the testing maximal voluntary isometric contraction, three variables (initial median frequency, regression slope, fatigue index) from the regression line of MDF data were measured in each exercise load. The results showed that the regression slope and fatigue index were significantly different for the biceps brachii, but not for the vastus lateralis initial MDF was not significant difference according to the exercise load on both muscles. The regression slope and fatigue index could monitor physiologic muscle change during fatiguing isometric exercise. The results showed that two MDF variables reflect the local muscle fatigue according to the exercise load.

  • PDF

Reproducibility analysis of surface EMG spike variables during isometric voluntary contraction of the biceps brachii muscle (이두박근의 등척성 자의 수축시 표면근전도 신호에서 검출한 스파이크 변수들의 재현성 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1246-1254
    • /
    • 2009
  • The reproducibility of initial value and change over time of surface EMG spike variables(MSA, MSF, MSS, MSD) was investigated in the biceps brachii muscle of 11 healthy subjects. Surface EMG signals were recorded during sustained isometric voluntary contractions for 30 seconds at three contraction levels, 20%, 50%, and 80%MVC, respectively. Each contraction was repeated three times in each of three different days for a total of nine contractions and 99 contractions per %MVC level across the eleven subjects. A total of 297 EMG signals across the different trials, days, subjects, and %MVC levels was saved for the subsequent analysis. The degree of reproducibility was investigated using the intraclass correlation coefficient(ICC) and the standard error of the mean(SEM) based upon the analysis of variance(ANOVA), Results for intercept showed higher reproducibility of the spike variables with about 60%-98% ICC than the variable(ARV, MNF) which had been analyzed before in other researches. And results for slope showed poor reproducibility of the spike variables with about 30%-70% ICC and they were comparable with the variables of other researches.

Muscle Activity Analysis According to Shoulder Injury of Golf Drive Swing (어깨 손상에 따른 골프 드라이버 스윙의 근활성도 분석)

  • Park, Jong-Yul
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.301-309
    • /
    • 2015
  • Objective : The purpose of this study was to describe the correlation between the activity of the muscles of upper and lower limbs of a golf driver swing according to shoulder injury. Method : The subjects were 18 professional golfers (7 male in KPGA and 11 female in KLPGA). Using surface electromyography, we evaluated muscle activities during the golf drive swing. Surface electrodes were used to record the level of muscle activity in the left Deltoid(MD), Triceps Brachii(TB), Pectoralis(PM), Trapezius(UT), Rectus Femoris(RF), Vastus Medialis Obilique(VMO), Biceps Femoris(BF), Gastrocnemius(GCM) muscles during the golfer's swing. The golf swing was divided into five phases: take away, forward swing, acceleration, early follow through, late follow through. Results : The results can be summarized as follows: MD, VMO had statistically significant difference in take away phases, GCM had statistically significant difference in acceleration phases, MD, PM, VMO had statistically significant difference in early follow through phases, PM had statistically significant difference in late follow through phases, Conclusion : Muscle activity of the 8 muscles(Deltoid, Triceps Brachii, Pectoralis, Trapezius, Rectus Femoris, Vastus Medialis Obilique, Biceps Femoris, Gastrocnemius) along the shoulder damage or absence of has shown that they are organically connected to each of the phases.