• Title/Summary/Keyword: Bioabsorbable interference screw

Search Result 10, Processing Time 0.022 seconds

Pretibial Ganglion after Anterior Cruciate Ligament Reconstruction with Bioabsorbable Interference Screw fixation $(Bioscrew^{\circledR})$ - A Case Report - (생분해성 간섭나사를 이용한 전방 십자 인대 재건술 후 발생한 결절종 - 증례보고 -)

  • Song, Eun-Kyoo;Shim, Sang-Don;Kim, Myung-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.188-191
    • /
    • 2002
  • The complication caused by a bioabsorbable interference screw composed of Poly-L-Lactic-Acid is rare after anterior cruciate ligament (ACL) reconstruction. We reported a case of a pretibial ganglion at the orifice of the tibial tunnel where the graft tendon had been fixed with a bioabsorbable interference screw $(Bioscrew^{\circledR})$ for ACL reconstruction using autogenous hamstring tendon. The patient was underwent ganglion excision and interference screw removal.

  • PDF

The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report - (생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 -)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Yang, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.87-90
    • /
    • 2006
  • The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.

  • PDF

Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note- (슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기-)

  • In Yong;Bahk Won-Jong;Park Jong-Beom;Hong Seung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Purpose : The purpose of this study was to introduce new femoral fixation technique using a cross-pin and a bioabsorbable interference screw in hamstring ACL reconstruction. Method : Semitendinosus and gracilis were harvested for quadrapled graft. After tibial tunnel had been made, femoral tunnel was made 35 mm in depth. Then the graft passed through the tunnels. Cross-pin was fixed through the drill hole which had been made through upper sleeve of the Rigidfix system. While pulling the graft, bioabsorbable interference screw was fixed through the anteromedial portal. Conclusion : We introduced the new femoral fixation technique using a cross-pin and a bioabsorbable interference screw as a good method with high fixation strength and tight graft-bone contact.

  • PDF

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Pretibial cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Autograft - A Case Report - (자가 슬괵근을 이용한 전방 십자 인대 재건술 후 발생한 전경골 낭종 - 증례 보고 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Ha, Dong-Jun;Jung, Hun-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • The pretibial cyst is a very rare complication after anterior cruciate ligament (ACL) reconstruction. It occurs whatever kind of graft choice or kind of graft fixation method at tibial side. It have been known such as graft necrosis at tibial side, extra-articular leakage of joint fluid through tibial tunnel, foreign body reaction due to breakdown of the bioabsorbable screw and incomplete incorporation of graft to bony tunnel as the cause of pretibial cyst. We experienced one case of pretibial cyst which had undergone ACL reconstruction with autogenous hamstring graft fixed with biodegradable interference screw. We report a rare case of pretibial cyst with literature review.

  • PDF

Pretibial Ganglion Cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction - A Case Report - (전방 십자 인대 재건술 후 발생한 전경골 결절종 - 1례 보고 -)

  • Jeon, Ho-Seung;Jeon, Seung-Ju;Kim, Jong-Min;Seo, Young-Ray
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.124-127
    • /
    • 2010
  • Pretibial ganglion cyst after arthroscopic anterior cruciate ligament reconstruction is a very rare complication, and a few are reported in and outside the country. Some authors report that it may break out with a variety of causes at any time. We experienced a case of pretibial ganglion cyst after arthroscopic anterior cruciate ligament reconstruction using Achilles tendon allograft and bioabsorbable interference screw in 34-year-old male. So we report this case including the cause and the treatment with a review of the literature.

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF