• Title/Summary/Keyword: Brain mapping

Search Result 186, Processing Time 0.028 seconds

A comparison with Result of Normalized image to Different Template image on Statistical Parametric Mapping of ADHD children patients (과잉행동장애 어린이의 SPM(Statistical Parametric Mapping)분석에서 서로 다른 Template image로 규격화된 SPEC 영상의 결과 비교)

  • Shin, Dong-Ho;Park, Soung-Ock;Kwon, Soo-Il;Joh, Chol-Woo;Yoon, Seok-Nam
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.71-78
    • /
    • 2003
  • We studied 64 ADHD children patients group($4{\sim}15\;ys$, mean age : $8{\pm}2.6\;ys$. M/F:52/12) and 12 normal group($6{\sim}7\;ys$, mean age : $9.4{\pm}3.4\;ys$, M/F:8/4) of the brain has been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In increase of blood flow(P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

  • PDF

A Study on the Effects of Electromagnetic Wave on Human Body - The Variation of Electroencephalogram by Blocking Electromagnetic Wave Materials and Aural Stimuli - (전자파가 인체에 미치는 영향 - 전자파 차폐소재와 청각자극에 나타난 뇌파전위의 변화 -)

  • Lee, Su-Jeong;Lee, Tae-Il
    • Fashion & Textile Research Journal
    • /
    • v.6 no.4
    • /
    • pp.503-510
    • /
    • 2004
  • The study is one of fundamental researches for the development of future smart clothing and textile products with blocking properties from electromagnetic waves by analyzing human physical symptoms in using electromagnetic products in such an environments. Among various textiles in the experiment, nano silver has shown the best blocking performance from electromagnetic waves, which decreases depending on the distance. The power spectrum distribution and the incidence of electroencephalogram between blocking materials and aural stimuli has shown that, ${\beta}$, wave appeared to be active in all channels except for $T_4$, whereas all waves appeared with processed materials and especially with nano silver silk(NSS), ${\alpha}$, ${\beta}$, ${\theta}$, ${\gamma}$ waves appeared active in all regions. As for the brain mapping of ${\alpha}$ wave according to time, there found a strong activity in $P_3$, $P_4$ of the parietal lobe, with all materials on all time regions. With silk nylon metal(SNM) and NSS, it appeared strong in $F_3$, $F_4$ as well. As for ${\beta}$, wave, the activity appeared strong in frontal lobe before 7min. 30sec, where it tends to diminish abruptly in 7min. 30sec. to 13min. 30sec. region. After 13min., it regained gradually. With NSS, it appeared strong in all areas except for the farthest $T_4$. The appearance of ${\nu}$ wave can be deduced as it can affect human body with its toxic property while the silver particles become nano-sized. Therefore, the study conducted with human participants requires a proper particle size of it which would not penetrate cellular tissues and a proper binder and binding treatment for it, to prevent the physical fatigues and the potential diseases. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.

Production and identification of antisera against mu-opioid receptor using synthetic peptide epitope (Synthetic peptide를 이용한 mu-opioid receptor에 대한 항혈청의 생산과 검정)

  • Lee, Jang-hern;Kwon, Young-bae;Han, Ho-jae
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.45-54
    • /
    • 1999
  • In the present study we have analyzed the characteristics and distribution of the mu-opioid receptor(MOR) by raising anti-peptide antisera to the C-terminal peptide of MOR. The antisera against MOR was produced in New Zealand White rabbit against 15 residue corresponding to amino acids, 384-398 of the cloned rat MOR. The antigenic peptide was synthesized using an Applied Biosystems 432 solid-phase peptide synthesizer. The specificity and identification of the antisera were tested by analysis of transfected cells, epitope mapping and immunohistochemical method. COS-7 cells electroporated with MOR cDNA were used to evaluate the characteristics and subcellular distribution of MOR. MOR immunoreactivity was prodominent in the plasmalemma and subcellular compartments such as endoplasmic reticulum, Golgi apparatus and vesicle like structure. Furthermore, both tissue sections and transfected cell lines could be immunostained with these antisera and the immunoreactivity was abolished when anti-MOR sera were preincubated with the peptide against which they were raised. Based on epitope mapping analysis, all antisera appeared to have a similar epitope, which was determined to be within the last amino acid, 391-398. Moreover, immunohistochemistry showed that MOR immunoreactivity was observed in many brain areas including cerebral cortex, striatum, hippocampus, locus coeruleus and the superficial laminae of the dorsal horn. These stained spinal cord and brain areas showed the mirrored pattern observed in auto radiographic studies of mu-opioid binding as well as a pattern similar to that seen by is situ hybridization for MOR. Thus, several lines of evidence support the conclusion that the antisera produced in the present study most likely recognize mu-opioid receptor. These results suggest that MOR antisera may be utilized as useful tool to analyze the physiological and pharmacological studies for mu-opioid receptor in the future.

  • PDF

Efficacy Assessment of Endovascular Stenting in Patients with Unilateral Middle Cerebral Artery Stenosis Using Statistical Probabilistic Anatomical Mapping Analysis of Basal/Acetazolamide Brain Perfusion SPECT (기저/아세타졸아미드 국소뇌혈류 SPECT의 확률 뇌지도 분석을 이용한 일측 중대뇌동맥 협착환자에서 시행한 스텐트 삽입술의 효용성 평가)

  • Kim, Hae-Won;Won, Kyoung-Sook;Zeon, Seok-Kil;Lee, Chang-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.280-286
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the hemodynamic changes after endovascular stenting in patients with unilateral middle cerebral artery (MCA) stenosis using statistical probabilistic anatomical mapping (SPAM) analysis of basal/acetazolamide (ACZ) Tc-99m ECD brain perfusion SPECT. Materials and Methods: Eight patients (3 men and 5 women, 64.8$\pm$10.5 years) who underwent endovascular stenting for unilateral MCA stenosis were enrolled. Basal/ACZ Tc-99m ECD brain perfusion SPECT studies were performed by one-day protocol before and after stenting. Using SPAM analysis, we compared basal cerebral perfusion (BCP) counts and cerebrovascular reserve (CVR) index of the MCA territory before stenting with those after stenting. Results: After stenting, no patient had any complication nor additional stroke. In SPAM analysis, 7 out of the 8 patients had improved BCP counts of the MCA territory and 7 out of the 8 patients had improved CVR index of the MCA territory after stenting. Before stenting, the mean BCP counts and CVR index in the affected MCA territory were 47.1$\pm$2.2 ml/min/100 g and -2.1$\pm$2.9%, respectively. After stenting, the mean BCP counts and CVR index in the affected MCA territory were improved significantly (48.3$\pm$2.9 ml/min/100 g, p =0.025 and 0.1$\pm$1.3%, p =0.036). Conclusion: This study revealed that SPAM analysis of basal/ACZ brain perfusion SPEG would be helpful to evaluate hemodynamic efficacy of endovascular stenting in unilateral MCA stenosis.

Hybrid Affine Registration Using Intensity Similarity and Feature Similarity for Pathology Detection

  • June-Sik Kim;Ho-Sung Kim;Jong-Min Lee;Jae-Seok Kim;In-Young Kim;Sun I. Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.39-47
    • /
    • 2002
  • The objective of this study is to provide a Precise form of spatial normalization with affine transformation. The quantitative comparison of the brain architecture across different subjects requires a common coordinate system. For the common coordinate system, not only global brain but also a local region of interest should be spatially normalized. Registration using mutual information generally matches the whose brain well. However. a region of interest may not be normalized compared to the feature-based methods with the landmarks. The hybrid method of this Paper utilizes feature information of the local region as well as intensity similarity. Central gray nuclei of a brain including copus callosum, which is used for feature in Schizophrenia detection, is appropriately normalized by the hybrid method. In the results section. our method is compared with mutual information only method and Talairach mapping with schizophrenia Patients. and is shown how it accurately normalizes feature .

An Exam Prep App for the Secondary English Teacher Recruitment Exam with Brain-based Memory and Learning Principles (뇌 기억-학습 원리를 적용한 중등영어교사 임용시험 준비용 어플)

  • Lee, Hye-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.311-320
    • /
    • 2021
  • At present, the secondary school teacher employment examination(SSTEE) is the only gateway to become a national and public secondary teacher in Korea, and after the revision from the 2014 academic year, all the questions of the exam have been converted to supply-type test items, requiring more definitive, accurate, and solid answers. Compared to the selection-type test items that measure recognition memory, the supply-type questions, testing recall memory, require constant memorization and retrieval practices to furnish answers; however, there is not enough learning tools available to support the practices. At this juncture, this study invented a mobile app, called ONE PASS, for the SSTEE. By unpacking the functional mechanisms of the brain, the basis of cognitive processing, this ONE PASS app offers a set of tools that feature brain-based learning principles, such as a personalized study planner, motivation measurement scales, mind mapping, brainstorming, and sample questions from previous tests. This study is expected to contribute to the research on the development of learning contents for applications, and at the same time, it hopes to be of some help for candidates in their exam preparation process.

Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping

  • Jeong, Kyle;Thapa, Bijaya;Han, Bong-Soo;Kim, Daehong;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.328-340
    • /
    • 2019
  • Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace's equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer's 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

A STUDY ON 3D BRAIN TOPOGRAPHY BASED ON PC (PC에 기반한 3차원 TOPOGRAPHIC 매핑 시스템에 관한 연구)

  • Kim, K.H.;Kwon, J.H.;Lee, D.H.;Lee, Y.H.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.362-365
    • /
    • 1997
  • To visualize electrical activities in the cerebral cortex, we develop the 3D topographic mapping system based on PC. For this work, we utilize OpenGL tool and an optimized interpolation method known as 3D barycentric algotithm, which has a little computational complexity. OpenGL processes the 3D coordinates, and 3D barycentric algotithm interpolates to get overall EEGs with EEGs measured from finite electrodes on 3D. To prove validity of this algorithm on the PC-based system, we developped Windows-based 3D topographic mapping program using the Barycentric algorithm. The result showed that the performance of this system is comparable to that of workstation in terms of speed and precision. Also, the result of clinical test was the same as that of a EEG technician's analysis.

  • PDF

Development of Algorithm for Prediction of Bead Height on GMA Welding (GMA 용접의 최적 비드 높이 예측 알고리즘 개발)

  • 김인수;박창언;김일수;손준식;안영호;김동규;오영생
    • Journal of Welding and Joining
    • /
    • v.17 no.5
    • /
    • pp.40-46
    • /
    • 1999
  • The sensors employed in the robotic are welding system must detect the changes in weld characteristics and produce the output that is in some way related to the change being detected. Such adaptive systems, which synchronise the robot arm and eyes using a primitive brain will form the basis for the development of robotic GMA(Gas Metal Arc) welding which increasingly higher levels of artificial intelligence. The objective of this paper is to realize the mapping characteristics of bead height through learning. After learning, the neural estimation can estimate the bead height desired from the learning mapping characteristic. The design parameters of the neural network estimator(the number of hidden layers and the number of nodes in a layer) are chosen from an estimation error analysis. A series of bead of bead-on-plate GMA welding experiments was carried out in order to verify the performance of the neural network estimator. The experimental results show that the proposed neural network estimator can predict the bead height with reasonable accuracy and guarantee the uniform weld quality.

  • PDF

T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence

  • E-K. Jeong;Lee, S-H.;J-S. Suh;Y-Y wak;S-A. Shin;Y-K. Kwon;Y. Huh
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.7-20
    • /
    • 1997
  • The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map.

  • PDF