• Title/Summary/Keyword: Build-up region

Search Result 95, Processing Time 0.036 seconds

Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region (선량보강(Build-up) 영역에서의 광자선 깊이선량률 측정을 위한 검출기의 특성 비교)

  • Kang Sei-Kwon;Park Suk Won;Oh Do Hoon;Park Hee Chul;Kim Su Ssan;Bae Hoonsik;Cho Byung Chul
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.77-81
    • /
    • 2005
  • To determine the appropriate method out of various available methods to measure build-up doses, the measurements and comparisons of depth doses of build-up region including the surface dose were executed using the Attix parallel-plate ionization chamber, the Markus chamber, a cylindrical ionization chamber, and a diode detector. Based on the measurements using the Attix chamber, discrepancies of the Markus chamber were within $2\%$ for the open field and increased up to $3.9\%$ in the case of photon beam containing the contaminant electrons. The measurements of an cylindrical ionization chamber and a diode detector accord with those of the Attix chamber within $1.5\%\;and\;1.0\%$ and after those detectors were completely immersed in the water phantom. The results suggest that the parallel-plate chamber is the best choice to measure depth doses in the build-up region containing the surface, however, using cylindrical ionization chamber or diode detector would be a reasonable choice if no special care is necessary for the exact surface dose.

  • PDF

Measurement of Skin Dose and Percentage Depth Does in Build-up Region Using a Fiber-optic Dosimeter (광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber. The dosimeter measure skin dose and percentage depth dose in a build-up region for an incident high energy photon beam. The scintillating light generated in the organic sensor probe embedded in a solid water phantom is guided by 30 m plastic optical fiber to a light-measuring device such as a PMT or an electrometer. In addition, using a fiber-optic dosimeter or a GAFCHROMIC EBT film, skin dose and percentage depth dose in the build-up region are measured and compared.

Skin Dose Distribution with Spoiler of 6 MV X-ray for Head and Neck Tumor (두경부암 치료를 위한 6 MV X-선 산란판의 제작과 산란분포 측정)

  • Lee Kyung-Ja;Chu Sung Sil
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.339-345
    • /
    • 1996
  • Purpose : This study was performed for adequate irradiating tumor area when 6 MV linear accerelator photon was used to treat the head and neck tumor. The skin surface dose and maximum build-up region was measured by using a spoiler which was located between skin surface and collimator. Methods : A spoiler was made of tissue equivalent material and the skin surface dose and maximum build-up region was measured varing with field size, thickness of spoiler and interval between skin and collimator. The results of skin surface dose and maximum build-up dose was represented as a build-up ratio and it was compared with dose distribution by using a bolus. Results : The skin surface dose was increased with appling spoiler and decreased by distance of the skin-spoiler separation. The maxium build-up region was 1.5 cm below the skin surface and it was markedly decreased near the skin surface. By using a 1.0-cm thickness spoiler, Dmax moved to 5, 10.2, 12.3 13.9 and 14.8 mm from the skin surface by separation of the spoiler from the skin 0, 5, 10, 15. 20 cm, respectively. Conclusion : The skin surface dose was increased and maximum build-up region was moved to the surface by using a spoiler. Therefore spoiler was useful in treating by high energy photon in the head and neck tumor.

  • PDF

Dose Evaluation at The Build Up Region Using by Wedge Filter (쐐기필터 사용에 따른 선량증가 영역에서 선량평가)

  • Kim, Yon-Lae;Moon, Seong-Kong;Suh, Tae-Suk;Chung, Jin-Beom;Kim, Jin-Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.341-348
    • /
    • 2014
  • Wedge filter could use to increase the dose distribution at the hot dose regions. We evaluated dose discrepancy at surface and build region in the infield and outfield that Metal Wedge (MW) and Enhance Dynamic Wedge (EDW) were interact with photon. In this paper, we used Gafchromic EBT3 film that had excellent spatial resolution, composed the water equivalent materials and changed the optical density without development. The set up conditions of linear accelerator were fixed 6 MV photon, 100 cm SSD, $10{\times}10cm^2$ field size and were irradiated 400 cGy at Dmax. The dose distribution and absorbed dose were evaluated when we compared the open field with $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ metal wedge and enhanced dynamic wedge. A $15^{\circ}$ metal wedge could increase the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. A $30^{\circ}$ metal wedge could decrease the surface and build up region dose than using a $30^{\circ}$ enhanced dynamic wedge. A $45^{\circ}$ metal wedge could decrease by large deviation the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. The dose of penumbra region at outfield were increased on the thick side but were decreased on the thin side. It could be decrease the surface dose and build up region dose, if the metal wedge filters were properly used to make a good dose distribution and not closed the distance of surface.

Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses (다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포)

  • Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1999
  • Purpose: TLD experiments were set up to measure the dose distribution and to analyze the influence on dose measurement of thin metal plate and solid water phantom. The aim of the present study was to investigate the build-up effect of metal plate loaded on TLD chip and depth dose in the controlled environment of phantom measurements. Materials and Methods: Measurements were done by using LiF TLD-100 loaded by a thin metal plate with the same surface area (3.2$\times$3.2 $\textrm{mm}^2$) as TLD chip. TLD chips loaded with one metal plate from three different metal plate (Tin, Copper, Gold) of different thicknesses (0.1, 0.15, 0.2, 0.3 mm) were used respectively to measure radiation dose. Using the TLD loaded with one metal plate, surface dose and the depth dose at the build-up maximum region were investigated. Results: Using a metal plate on TLD chip increased the surface dose. Surface dose curve shows the dose build-up against equivalent thickness of metal to water. The values of TL reading obtained by using metal plate at depth of build-up maximum are about 8% to 13% lower than those obtained by normal TLD chip. Conclusion: The metal technique used for TLD dosimetry could provide clinicals information about the build-up of dose up to 4.2mm depth in addition to a depth dose distribution. The results of TLD with a metal plate measurements may help with decisions to boost or bolus certain areas of the skin.

  • PDF

ROK Navy's Role for a Confidence Building and Mutual Cooperation on the East Asian Sea (역내 해양협력 및 신뢰증진을 위한 한국 해군의 기여방안)

  • Park, Young-June
    • Strategy21
    • /
    • s.30
    • /
    • pp.143-176
    • /
    • 2012
  • We are witnessing the growing maritime tension on the East Asian sea these days. Each naval powers in the region are competing each other to acquire more advanced naval capabilities. Based upon the rapid economic development, China is actively beefing up its naval capabilities and expand its boundary of naval activities all over the East Asian region. Chinese Navy already unveiled its expansive naval strategy replacing the traditional concept of 'Near-Sea Defense' with the new concept of 'Far-Sea Defense' strategy. In response to potential rival's naval build up, the U.S. is redeploying its naval forces focusing on the Asia-Pacific region. The U.S. enhances its joint naval exercises with the countries in the region, such as Japan, India, Australia and so on. In addition, Washington is devising new naval strategy under the concept of 'Air-Sea Battle' to deter Peking's so-called 'Anti-Access/ Area Denial(A2AD)' strategy. As a close ally of the U.S., Japan also disclosed its clear intention to strengthen the Maritime Self Defense Force(MSDF)'s capabilities by introducing the new concept of 'Dynamic Defense Force' in 2011. Under the new concept, JMSDF is pursuing the additional acquisition of submarines, quasi-aircraft carriers, Aegis-equipped destroyers, etc. Under the new president's strong leadership, Russia is also invigorating the naval build-up. Especially, Russia is fortifying the Pacific Fleet's naval assets by deploying new-type of naval ships such as the Mistral which was imported from France. In the midst of competitive naval build-up among the major naval powers in the region, we are observing the growing maritime conflicts on the East China Sea as well as South China Sea. Those naval conflicts can pose severe threats to our national interests. Maritime conflicts on the East or South China Sea can imperil our sea lanes which will be indispensible for national economic development. Neighboring countries' maritime conflicts also will cast an uncertainty on the path to mobilize international cooperation to resolve the North Korean issues. We should contribute to ease the maritime tension in the region by various ways. First, we should actively galvanize the bilateral maritime dialogue among the major naval powers in the region. Second, we also should take the lead to form a multilateral maritime cooperation mechanism in the region. Above all, we should set the aim to be a peaceful maritime power who can contribute to a building of stable maritime order in the region with a considerable naval power.

  • PDF

Effects of Smooth and Textured Disks on Tribocharge build-up at a Head Disk Interface of HDD (HDD에서 Smooth 디스크와 Texture 디스크가 IDI의 마찰대전에 미치는 영향)

  • Lee Dae-Young;Lee Rae-Jun;Kang Pil-Sun;Han Je-Hee;Hwang Jungho;Kim Dae-Eun;Cho Keung-Youn;Kang Tae-Sik
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.96-102
    • /
    • 2005
  • The tribocharge build-up in the slider disk interface can cause ESD (electrostatic discharge) damage. In turn, ESD can cause severe melting damage to MR or GMR heads. We investigated the tribovoltage/current build-up with smooth and textured disks in HDD, operating at increasing disk accelerations. We found that tribe-voltage/current were generated during pico-slider/disk interaction and those levels were about 0.1 ${\~}$ 0.3 V and 10 ${\~}$ 40 pA, respectively. Tribovoltage/current were abruptly increased and dissipated within the acceleration time in the case of textured disk but in the case of smooth disk tribovoltage was continuously increased until the end of uniform velocity region and the tribocurrent did not dissipate within the acceleration time. In the case of textured dist tribovoltage/current was reduced with increasing disk acceleration, but in the case of smooth disk it was increased.

  • PDF

Effect of Transverse Magnetic Field on Build-up Region of 6 MV Photon Beam (6 MV 광자선의 선량 상승 영역에 대한 자기장 영향)

  • Shin, Seong Soo;Choi, Wonsik;Ahn, Woo Sang;Kwak, Jungwon
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • The purpose of this study was to present an improved method of dose modulation over the increase of build-up for existing 6 MV photon beam. Two neodymium permanent magnets with a strength of 0.5 T (Tesla) were applied with a magnetic field perpendicular to the photon beam. The effects of dose on build-up region with or without the magnetic field were measured according to the magnet-to-magnet distance (MMS) and the magnet-to-surface distance (MSD). For MMS = 6 cm and MSD = 2.5 cm, $D_{0mm}$, $D_{2mm}$, $D_{5mm}$, and $D_{10mm}$ showed improved doses of 6.8 %, 14.6 %, 6.9 %, and 2.1 %, respectively, as compared with 6 MV open beam. In this study, the device with low strength magnetic field can be applied directly to the outside of the human body when the target volume located close to the skin is delivered with radiation. It is expected that the method of build-up modulation using a low strength magnetic field will be feasible in the clinical applications.

Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus (Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성)

  • Kim, Sung Joon;Lee, Seoung Jun;Moon, Su Ho;Seol, Ki Ho;Lee, Jeong Eun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.225-232
    • /
    • 2014
  • We evaluated the effect of scatter on a build-up region based on the measured percent depth dose (PDD) of high-energy photon beams that penetrated a handmade build-up modifier (BM) as a substitute of bolus. BM scatter factors ($S_{BM}$) were calculated based on the PDDs of photon beams that penetrated through the BM. The calculated $S_{BM}$ values were normalized to 1 at the square field side (SFS) of 30 mm without a BM. For the largest SFS (200 mm), the SBM values for a 6-MV beam were 1.331, 1.519, 1.598, 1.641, and 1.657 for the corresponding BM thickness values. For a 10-MV beam, the $S_{BM}$ values were 1.384, 1.662, 1.825, 1.913, and 2.001 for the corresponding BM thickness values. The BM yielded 76% of the bolus efficiency. We expect BM to become useful devices for deep-set patient body parts to which it is difficult to apply a bolus.

A Study on the Use of 10 MV X-Ray with Lead Absorber for Treatment of Head and Neck Tumors (10MV X선(線)을 이용(利用)한 경부(頸部) 방사선(放射線) 치료시(治療時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kim, Hyung Sik;Kang, Wee Saing;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.25-28
    • /
    • 1983
  • Anterior and posterior parallel opposed field technique covering entire neck is desirable for elimination of junctional problems in treating upper neck with bilateral parallel opposed fields and lower neck with anterior one field. For good dose distribution in neck, dose in build-up region should be high for anterior field and should be low for posterior field. And so, with 10 MV X-ray, lead absorber was used for anterior field only. The adequate thickness of lead absorber, absorber-skin separation, width of central cord block for posterior field and anterior & posterior field weight were studied using film dosimery. The results are as follows. 1. As the thickness of the lead absorber increased the dose in build-up region increased. 2. As the absorber-skin separation decreased the dose in build-up region increased. 3. The adequate thickness of lead absorber was around 5.6mm. 4. The adequate absorber-skin separation was around 5cm. 5. The adequate posterior cord block width was 3cm. 6. 4:1 weighting for anterior and posterior field was adequate. And so with this technique, adequate dose distribution could be made as well as elimination junction problems.

  • PDF