• Title/Summary/Keyword: Building Orientation

Search Result 239, Processing Time 0.025 seconds

An Analysis on Building Energy Load along Core Position, Area Ratio and Orientation (코어 위치와 종횡비 및 방위에 따른 건물 에너지 부하 분석)

  • Kim, Jin-Ho;Park, Woo-Pyoung;Shin, Seung-Ho;Min, Joon-Ki;Kim, Dong-Hoon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.1
    • /
    • pp.15-19
    • /
    • 2013
  • In this Study, effect of core position, area ratio and orientation of building on energy load is examined using TRNSYS17. This parameters are major parameters of the conceptual design stage. Reference model is square floor plan($1,444m^2$), centered core and 29% core area ratio. As the results, without considering the building orientation, the annual heating load of central building with 1:1 area ratio is lowest ($10.33kWh/m^2yr$) and the annual cooling load of off-central building with 1:1 area ratio is lowest ($59.27kWh/m^2yr$). As area ratio is bigger, cooling load is lower and heating load is higher. But if we consider building orientation, orders of heating load and cooling load are changed for area ratio and orientation.

Space study on Lighting Performance For Residential Buildings By using Simulation Analysis (시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구)

  • Lim, Tae Sub;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

A study on analysis of energy consumption of Detached house by U-value and SCs of windows and Building Orientation (창의 종류 및 차폐계수 변화와 건물 향에 따른 단독주택의 에너지요구량 분석)

  • Jeong, Su-Hui;Park, Hyo-Sun;Lee, Byung-Yun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • Annual energy consumption in detached houses are affected mainly by thermal performance of envelope. In particular the performance of glasses are critical due to global wanning and climatic change. Therefore, this research analyzes annual consumption of cooling and heating energy with various combination of U-value, shading coefficient and building orientation. The simulation results shows that shading coefficient of glazing contributes to the changes of proportion of heating and cooling energy demand and the optimized shading coefficient for minimizing energy consumption varies with buildings orientation.

Development of Energy Optimized Geometry Using BIM for Super Tall Office Building in Early Design Stages (BIM을 이용한 건축물 초기 디자인 단계에서 초고층 업무용 건물의 최적 에너지 형태개발)

  • Ryu, Han-Soo;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.83-91
    • /
    • 2011
  • There are many researches to make low-energy building. Lots of them focus on facility systems and insulation performance of building materials. However, not only systematic solutions but also approaches in early design stages are important to reduce energy consumption. Using BIM(Building Information Modelling) is considered as an effective and efficient way to simulate building energy and decide alternatives than traditional energy simulation because BIM based energy simulation makes to reduce much time for energy modeling. This study focuses on development of optimized geometry for super tall office buildings in Seoul, Korea. Specifically, length to width ratio and building orientation are main topics of this study because these two topics are the most basic and preceding factors deciding mass design. In this study, Revit MEP 2011 and Ecotect Analysis 2011 are used to make case models and calculate energy load in early design stages. Energy properties of material abide by Korean Standards for Energy Conservation in Building, Korean Guideline for Energy Conservation in Public Office and ASHRAE Standard in USA. This study presents best length to width ratio of plan and optimized orientation by evaluating the case models. Furthermore, this study suggests what should be considered for each case to decrease energy load.

A Numerical Method for Macro-fiber Distribution and Orientation In Hardened Concrete Components

  • Li, Mao;Kim, Jin-man;Choi, Hong-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.85-86
    • /
    • 2017
  • Fiber reinforced concrete as a construction material has been widely used. Fibers, as the reinforced component, the physical properties and the distribution influence the engineering properties of the composite. To illustrate the engineering properties, fiber distribution and orientation are necessary. Steel fibers can be easily captured by X-ray, but it is difficult them to express being numerical because they don't show as perfect circular shape on the grinding face. To get the more exact information for this, the numerical method for the orientation and distribution of fibers have to be more elaborately. This paper presents a possible method which makes the calculate for orientation possible.

  • PDF

Post-earthquake fast building safety assessment using smartphone-based interstory drifts measurement

  • Hsu, Ting Y.;Liu, Cheng Y.;Hsieh, Yo M.;Weng, Chi T.
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.287-299
    • /
    • 2022
  • Rather than using smartphones as seismometers with designated locations and orientations, this study proposes to employ crowds' smartphones in buildings to perform fast safety assessment of buildings. The principal advantage of using crowds' smartphones is the potential to monitor the safety of millions of buildings without hardware costs, installation labor, and long-term maintenance. This study's goal is to measure the maximum interstory drift ratios during earthquake excitation using crowds' smartphones. Beacons inside the building are required to provide the location and relevant building information for the smartphones via Bluetooth. Wi-Fi Direct is employed between nearby smartphones to conduct peer-to-peer time synchronization and exchange the acceleration data measured. An algorithm to align the orientation between nearby smartphones is proposed, and the performance of the orientation alignment, interstory drift measurement, and damage level estimation are studied numerically. Finally, the proposed approach's performance is verified using large-scale shaking table tests of a scaled steel building. The results presented in this study illustrate the potential to use crowds' smartphones with the proposed approach to record building motions during earthquakes and use those data to estimate buildings' safety based on the interstory drift ratios measured.

Entrepreneurial Orientation and Organizational Performance: The Mediating Role of Knowledge Capabilities

  • Batra, Shruti
    • Asia-Pacific Journal of Business
    • /
    • v.6 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • In this study, we identified the various mechanisms through which entrepreneurial orientation impacts firm performance. We proposed that entrepreneurial orientation assists organizations in building cultural, structural, human and technical knowledge capabilities, which in turn lead to sustainable competitive advantage. We tested our proposed hypothesis using data collected from 76 managers of small entrepreneurial firms. We found that cultural knowledge capabilities are the strongest mediators of entrepreneurial orientation and firm performance relationship. By bringing in knowledge capabilities in the literature of entrepreneurial orientation, we open new directions for research. Our findings have implications for theory as well as practice.

  • PDF

An Analysis on Building Energy Reduction Effect of Exterior Venetian Blind According to Orientation and Reflectance of Slat (블라인드형 외부차양의 종류 및 반사율에 따른 건물에너지 저감효과 분석)

  • Kim, Jin-Ah;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.28-34
    • /
    • 2013
  • It is essential to reduce building energy consumption in office building because government enact policy which encourages building energy certification from 2013. Office building has high cooling energy demand due to large glazed area of facade in these days. Shading devices can be an alternative of reducing high cooling energy demand. So, this study simulated a variety of exterior venetian blinds to know how much building energy be affected by orientation and reflectance of slat. The results of this study are based on Seoul weather data. The following is a summary of this study. 1) As a slat of venetian blinds has the lower reflectance, the more building energy reduced. Reflectance is usually affected by color and material of slat. In case reflectance is 0.2 reduce 4% of building energy than reflectance is 0.8. 2) Horizontal exterior venetian blinds are more effective than vertical exterior venetian blinds in all of orientation. Horizontal shape is average 16% more effective in shading effect than vertical shape. 3) In this case study, the most effective shading device is low reflectance horizontal exterior venetian blinds that result about 18% building energy reduction than no shade model. The results of this research can be used to plan shading devices for energy conservative office building.

Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings (스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이)

  • Jae-Hyang Kim;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.