• 제목/요약/키워드: Burying

검색결과 112건 처리시간 0.035초

화본과 녹비작물 시용을 위한 파쇄·매몰 장치 개발 (Development of a Shredding and Burying Machine for the Application of Gramineae Green Manure Crops)

  • 홍종태;유병기;오권영;이충근;임종국;노진상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.411-419
    • /
    • 2009
  • This study was carried out to develop a shredding-burying machine for application of gramineae green manure crops that were tall and had high biomass yield such as sudan grass and rye. We made a prototype to operate both shredding and burying concurrently to attach at middle-sized tractors. Field tests were performed with the prototype to treat rye and sudan grass. The test results showed that the average cutting length became shorter and the quantity of entwined stem became obviously decreased when the PTO shaft speed was fast and running speed was slow. Also, We found, when the cut stem length became shorter, the burying ratio became more increasing and the PTO power requirement became more decreasing. Working efficiency of the prototype was better than conventional Rotary. The test results for treating rye/sudan grass with prototype showed that average cutting length was 21.2/22.5 cm and burying ratio was 98.4/98.1% when the PTO shaft speed was 1,000/1,000 rpm and running speed was 0.25/0.17 m/s. Also, the working performance of the prototype was 0.79 and 1.14 h/10 a for rye and sudan grass, respectively. Finally, we found that the prototype of shredding-burying machine was better for labor than conventional method that required at least 3 times bigger tractor.

Weed Emergence as Affected by Burying Depth and Water Management

  • Moon, Byeong-Cheul;Park, Sung-Tae;Kim, Soon-Chul;Kwon, Suk-Ju;Mortimer, Andrew-Martin;Collin Piggin
    • 한국작물학회지
    • /
    • 제44권1호
    • /
    • pp.32-37
    • /
    • 1999
  • The experiment was conducted to investigate emergence response of lowland weeds at different soil moisture contents, burying depths and upon changes in soil moisture. Rice germination was over 50% at all burying depths under aerobic condition, but the emergence rate of the soil surface placed seeds in saturated and flooded conditions decreased by 19% and 29%, respectively, as compared with that of aerobic condition. Rice seeds at burying depth of over 3 cm did not emerge at all. The emergence rate of Echinochloa crus­galli (L.) Beauv. in aerobic condition was lower than 30%, but the emergence pattern of E. crus galli (L.) Beauv. at different soil moisture contents and seeding depths was similar to that of rice. Emergence behavior of lschaemum rugosum Salisb., Ludwigia octovalvis (Jacq.) Raven and Sphenoclea zeylanica Gaertn. which are dominant lowland weed species in the Philippines also differed depending on soil moisture conditions and burying depths. lschaemum rugosum Salisb. emerged at all burying depths under aerobic condition, whereasLudwigia octovalvis (Jacq.) Raven emerged only at 0 cm deep under saturated and aerobic condition and Sphenoclea zeylanica Gaertn. at 0 cm deep under flooding condition. Weed seeds planted at 1, 3, and 5 cm deep in continuous flooded and saturated condition did not emerge at all, but upon a change of soil moisture condition from saturated to drainage (S$\rightarrow$D) and flooded to drainage (F$\rightarrow$D), grass weeds began to germinate again and the average emergence rate in S$\rightarrow$D and F$\rightarrow$D were 26% and 5% forE. crus­galIi (L.) Beauv., 9% and 8% forI. rugosum SaIisb., respectively. Weed seeds buried in soil in the pot showed great emergence at S$\rightarrow$D but did not emerge under continuous flooded condition. The diversity index accounting for dominance degree and occurrence aspect of weed, was the lowest at F$\rightarrow$D.

  • PDF

국내 지중송전선로 포설형태와 시스순환전류와의 상관관계 검토 (A Study on the Correlation between Sheath Circulating Current and Installation Type of Domestic Underground Transmission Power Cables)

  • 김남열;정채균;이종범;윤양웅;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.484-486
    • /
    • 2002
  • In this paper, installation type is analyzed into a single and mixed burying type on burying situation of domestic underground transmission cables, and problem of underground cable is discussed with investigating the relation between burying type and sheath circulation current. Investigated cable systems are 520 T/L which have 512T/L for 154kV and 8T/L for 345kV. The authors consider that the analysis of sheath circulating current with burying type will contribute for setting reduction methods of sheath circulation current.

  • PDF

금연침(禁煙鍼)의 침자수법(鍼刺手法)에 따른 효과(效果)의 임상적(臨床的) 고찰(考察) (Clinical Research on Effect by the Technique of Quit-smoking Acupuncture Therapy)

  • 김민수;이정현;조현석;박영재;이은용
    • Journal of Acupuncture Research
    • /
    • 제19권4호
    • /
    • pp.27-41
    • /
    • 2002
  • Objective : The purpose of this study is to compare the effect of two other groups(Group A and B) which were treated with two other auricular acupuncture therapy to quit smoking. Methods : Seventy three high-school students were devided in two groups. Group A was treated with auricular acupuncture therapy by burying a needle in one side ear. Group B was not only treated with auricular acupuncture therapy by burying a needle in one side ear, but also treated with venesection on the other side ear. The effects of auricular acupuncture therapy to quit smoking were evaluated at two weeks and six months after the therapy. Results : Group A's score to quit smoking after the auricular acupuncture therapy was higher than Group B's score. Conclusions : Treating with auricular acupuncture therapy by burying a needle in one side ear and venesection on the other side, was effective neither on decreasing the amount of smoking nor on decreasing the desire to smoke compared with the only needle burying treatment.

  • PDF

압전발전 모듈의 안정성 해석 및 최적 매립위치 결정 (Stability Analysis of Piezoelectric Module and Determine of Optimal Burying Location)

  • 손인수;김지원;주홍회;조대환
    • 한국산업융합학회 논문집
    • /
    • 제26권1호
    • /
    • pp.193-199
    • /
    • 2023
  • In this study, an analysis was conducted to analyze the structural stability of the piezoelectric power generation module and to determine the optimal burying hole interval for concrete, the installation site of the power generation module. A piezoelectric element refers to a functional ceramic having a piezoelectric direct effect that converts mechanical energy into electrical energy and a piezoelectric reverse effect. In the analysis of the piezoelectric power generation module, the load condition was applied with about 16 tons and a total of 10 wheels in consideration of the container trailer. The purpose was to evaluate the stability of major components of the piezoelectric power generation module through finite element analysis. In order to determine the optimal burying location of the concrete ground for burying the piezoelectric power generation module, the stability of the ground structure according to the distance of the holes was determined. As a result of the analysis, the maximum stress of the piezoelectric power generation module was generated in the support spring, showing a stress of about 276.7 MPa. It was found that the spacing of holes for embedding the piezoelectric power generation module should be set to a minimum of 100 mm or more.

보온피복재 종류가 '거봉' 포도 유목의 월동시 온도 차이, 발아 및 근두암종병 발생에 미치는 영향 (The Differences of Temperatures, Growth and Crown Gall Occurrence in Young 'Kyoho' Grapevines According to Heat Conservation Materials during Winter)

  • 남상영;김선규;김경미;정재현;최관순
    • 원예과학기술지
    • /
    • 제16권4호
    • /
    • pp.517-519
    • /
    • 1998
  • 보온 피복재 종류가 거봉 포도 유목의 월동시 동해방지, 노동력 절감 및 근두암종병 발생 억제에 미치는 영향을 구명하기 위하여 11월 하순에 흙속매몰, 보온덮개, 보온덮개+짚, 부직포, 부직포+짚 등의 보온 피복재를 달리하여 시험한 결과, 월동기간 중 흙속매몰, 보온덮개+짚 피복에서 최고와 최저 온도차가 각각 $2.8^{\circ}C$, $6.4^{\circ}C$로 작았으며, $-10^{\circ}C$ 이하시의 보온효과도 노지 기온에 비하여 5~7배 높았다. 발아는 보온덮개+짚, 부직포+짚에서 시작이 빨랐으며, 발아율도 흙속매몰에 비하여 각각 22%, 7% 높았다. 주지경, 절간장 그리고 신초장은 흙속매몰, 피복재+짚 처리에에서 굵거나 길었으며, 근두암종병 발생은 무피복에 비하여 피복처리에서, 피복처리 중에는 흙속매몰에서 가장 심하였다. 작업단계별 노동력 투하량은 흙속매몰(관행)에 비하여 보온재 피복에서 44~57% 절감되었다.

  • PDF

Germination Characteristic of Rhizomes of Major Monocotyledonous Weeds in Coconut Plantations of Sri Lanka

  • Senarathne, S.H.S.;Bandara, D.M.B.M.;Sangakkara, U.R.
    • 한국잡초학회지
    • /
    • 제32권3호
    • /
    • pp.180-187
    • /
    • 2012
  • Panicum maximum, Panicum repens, Imperata cylindrica, Pennisetum polystachion and Cyperus rotundus are five rhizomatous grass weeds that exist and are problematic in the coconut lands of Sri Lanka. Rhizomatous weeds are the most difficult to control because of their vegetative reproduction by underground propagules. Therefore chemical and biological techniques have failed to control these weeds to acceptable levels. Experiments were conducted to investigate the impact of depth of burial, duration of sun drying or duration of air drying rhizomes of the selected weed species on germination. Depth of burial reduced germination of all species. Burying rhizomes at depths less than 10 cm inhibited germination of P. maximum and P. polystachion. Burying depths below 30~40 cm inhibited germination of all species. Sun drying or air drying rhizomes for durations less than 5 days inhibited germination of P. maximum and P. polystachion. Germinations of all species were inhibited by sun drying rhizomes for 15 days or air drying rhizomes for 20 days. Sun drying of rhizomes of all species for five days reduced the moisture content to a greater extent than air drying. The results indicated that burying rhizomes at the depthsbelow 30~40 cm, sun drying rhizomes for durations beyond 15 days or air drying rhizomes for durations beyond 20 days would be effective in controlling germination of these species. The investigations of the experiments also suggest that keeping rhizomes on the soil surface without burying, sun drying rhizomes or air drying rhizomes for durations of 5~15 days would produce weak plants.

순천시의 폐사가축 처리실태에 관한 연구 (Farm Animal Mortality Management Practices in Sunchon-si)

  • 홍지형
    • 한국축산시설환경학회지
    • /
    • 제16권3호
    • /
    • pp.245-252
    • /
    • 2010
  • 축산업의 대규모 전업화로서 폐사가축이 급증되어서 대기, 수질, 토양, 지하수 등의 환경오염 및 쥐. 파리. 까마귀 등의 썩은 고기를 좋아하는 위해동물 번식으로 인하여 자연환경이 오염되어가고 있다. 전라남도 순천 지역 중심의 축종별 호당 연간평균 사육두수는 양계농가 251,000마리, 양돈농가 2,600두, 한우농가 142두 및 낙농가 92두 등 이었으며, 호당 연간추정 폐사가축 발생량은 양계농가 0.46톤, 양돈농가 15.32톤, 한우농가 0.36톤 및 낙농가 1.33톤 등이었다. 순천지역 축산농가의 연간 추정 폐사가축 발생량은 2,754톤 이였으며, 특히 양돈농가 폐사가축 발생량은 1,287톤으로 전체발생량의 47%를 차지하였다. 폐사가축 처리방식은 산지와 과수원 등에 매몰처리 (42%)와 축분에 투기처리 (36%)가 대부분 (78%)이며, 개별농가 사정에 따라서 렌더링, 간이소각, 침지소화 및 사체처리기 등이 활용되었다. 폐사가축처리시설 선정은 매몰처리로 발생하는 수질 및 대기오염, 위해동물 발생, 질병확산 위험 등이 없고, 처리비용이 다른 방법보다 저렴한 폐사가축 퇴비화시설 도입이 필요하였다.

멸종위기 야생생물I급 흰수마자의 모래 선택과 잠입 행동에 관한 연구 (Substrate Selection and Burying Behaviour of Sand-dwelling Endangered Freshwater Fish, Gobiobotia naktongensis)

  • 김근식;허문성;김진;박창득;윤주덕
    • 생태와환경
    • /
    • 제56권4호
    • /
    • pp.375-383
    • /
    • 2023
  • 모래잠입 어류는 모래 하상에 잠입하여 살아가는 생물로, 잠입을 통해 포식자 회피, 먹이 포획, 에너지 보존 등 생존에 이득이 있다. 국내에 서식하는 흰수마자는 전형적인 모래잠입 특성을 보임에도 불구하고 지속적인 개체군 감소로 인해 멸종위기종으로 지정되어있다. 본 연구에서는 흰수마자의 감소원인 파악을 위하여 모래크기 선호도 및 잠입 행동을 평가하였다. 전반적으로 1 mm 이하의 모래를 선호하는 것으로 확인되었으며, 유량에 따라 모래크기의 선택이 차이가 발생하였다. 또한 수온이 낮아짐에 따라 모래에 보다 깊이 잠입하였고, 잠입하는 깊이는 흰수마자의 크기별로 차이가 있는 것으로 나타났다. 흰수마자의 모래 선호도 연구 결과 전반적으로 개체군이 감소하는 원인은 댐, 보 등의 건설로 인한 물리적인 하상구조의 변화로 사료되었다. 특히, 구조물 건설 상류부의 정수역 형성으로 인한 실트와 진흙의 하상 내 축적과 하류부에 세립질 퇴적물 유입 감소 및 침식으로 인한 장갑화로 서식처 변형이 발생하여 잠입에 문제가 발생한 것으로 판단되었다. 흰수마자를 비롯한 모래잠입 어류는 모래 하상 구조가 생존 및 서식에 중요한 역할을 하기 때문에 이를 관리할 수 있는 효율적 전략 수립 및 서식지 관리가 필요하다.

해저케이블 매설심도 측정오차 저감 방법에 관한 연구 (A Study on the Method to Minimize Measuring Burial Depth Error for Submarine Cable)

  • 안용호;김용학;한정열;이유진;한병성
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.329-334
    • /
    • 2012
  • The distribution submarine cables are normally used for power supply at island, which are mostly installed in the southern coast of KOREA, and partially installed in the west coast and Jeju-Island. There are two way of submarine cable burying system, buried and unburied type. Since 2003, KEPCO is entirely being constructing the distribution submarine cable by buried type. In this case, 'burial depth' is key index for evaluating the suitability of the buried situation. Therefore, the measurement accuracy of 'burial depth' is a big issue for burying system in the distribution submarine cable. This paper demonstrates the measurement error of burial depth that is affected by electrical factor such as grounding type of submarine cable in case of magnetic field detection method, and indicates the method to reduce the measurement error in buried type of distribution submarine cable system.