• Title/Summary/Keyword: Busan Metro Line 3

Search Result 9, Processing Time 0.022 seconds

An interior noise characteristic analysis of Busan Metro Line 3 (부산 도시철도 3 호선 실내소음 특성분석)

  • Ahn, Chan-Woo;Hong, Do-Kwan;Han, Geun-Jo;Gang, Hyeon-Uk;Lee, Kwon-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.362-367
    • /
    • 2010
  • This paper deals with the correlation between the interior noise and the floor vibration of the train from rolling, impulse and friction in Busan Metro line 3. The correlation is verified by sound and vibration measurement causing friction between the railway and the wheel. If ANC(Active Noise Control) system can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 1.8-4.8 dB in squeal noise. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

  • PDF

Analysis of Curve Squeal Noise for Busan Metro Line 3 (부산 도시철도 3호선 차량 곡선부 스퀼소음 특성)

  • Hong, Do-Kwan;Ahn, Chan-Woo;Han, Geun-Jo;Gang, Hyeon-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.427-435
    • /
    • 2011
  • This paper deals with the measurement and analysis of the squeal noise according to the curvature of rail. The squeal noise is generated by the friction between the railway with curve and the wheel. The squeal noise is a big problem in Busan Metro Line 3. If the developing panel type ANC(Active Noise Control) system which is attached to the floor can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 4-4.8 dB in squeal noise above the curvature of R400. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

A Study on the Construction Demand for Network of Metro Railroad in Busan-Ulsan-Gyeongnam Area - In the place of National Road No.7 - (부울경 광역도시철도망 구축 필요성에 관한 연구 - 국도 7호선 중심으로 -)

  • Choi, Yang Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6D
    • /
    • pp.771-778
    • /
    • 2011
  • Preliminary feasibility study on Busan metro line #1 in Yangsan line (Nopo-Bukjeong) depending on active volume of mass transportation between Yangsan city and Busan city was conducted. As the study concluded that it's valid, the necessity to establish the metro railroad network connecting to Busan, Ulsan and Gyeongnam Province is demanded to improve the transportation issues in Ungsang area vulnerable to metro service and to drive the balanced development between metropolitan cities. In addition, the volume of transportation depending on methods in target areas and road traffic assignment are surveyed to put a stress on the necessity to establish the metro railroad network. As the demand of transportation for alternative lines is predicted, the budget and benefits for construction for each alternative line set for the rough economic analysis depending on traffic volume for each method and traffic assignment results. The total project budget necessary for construction of proposal line #1 set as effective one among target three lines in this project is calculated in 794.32 billion won. Construction accounts for the most expensive in expenses for project and contingency allowances, purchases for vehicles and collateral expense are followed in orders. However, compensation for lands is not counted. In particular, according to economic analysis in proposal #1, ratio of benefit/cost (B/C) is 0.584, net present value (NPV) is -217.47 billion won, the internal rate of return (IRR) is analyzed in 0.604 %. At the current stage, it is not economically feasible, but the B/C is 0.737 in long-term upon construction of Yangsan line between Wolpheong and Yongdang which is proposal line #3. Therefore, when Busan metro basic plan is reorganized to aim the benefit of residents in Ungsang area vulnerable to the metro service, we think it must be necessary to establish the metro railroad network connecting to Busan-Yangsan-Ulsan which is proposal line #2 by extending the existing Sinjeong line and including this task line in high-ranked plan related to metro railroad.

Interior Noise and Low Frequency Noise Characteristics of Busan Metro Line 3 Noise (부산도시철도 3호선 실내소음 및 저주파 소음 특성)

  • Hong, Do-Kwan;Jeong, Jae-Boo;Jung, Seung-Wook;Gang, Hyun-Wook;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1113-1120
    • /
    • 2012
  • This paper deals with the analysis of interior noise and low frequency noise characteristic for the Busan citizens to use public transport, Busan Metro Line 3. The interior noise evaluation index, articulation index(AI) is evaluated the lower value about average 22 % in a whole range, this is difficult to have a conversation. Also, noise criteria(NC) curve is partially evaluated as NC-65 below 2000 Hz, space type is evaluated as factories. Another of interior noise evaluation index, preferred speech interference level(PSIL) is evaluated the upper value about average 66 dB(A) in a whole range, this is evaluated to be interrupted. In the case of low frequency noise(20~200 Hz), the measurement of low frequency noise is assessed largely beyond noise criteria of ISO 226. The low frequency noise should be reduced because low frequency noise affects on psychological stress and displeasure although low frequency noise is not recognized by auditory sense. The low frequency noise criteria and guideline will be enacted from now on in Korea.

The Study of Sound Level Specification of Subway Line II in Busan (부산 지하철 2호선 소음 특성 연구)

  • Jeong Kyung-Won;Yoon Na-Na;Kim Joo-In;Kwak Jin;Kim Yung-Tae
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.287-292
    • /
    • 2006
  • The purpose of this paper is to evaluate the noise level and source, reduce the subway line II noise. As a result of measurement of subway line II in Busan the highest value section of uproad line was from Jigegol to Motgol by 89 dB(A). The sections of conversation and listening interference(over 80 dB(A)) were 21 sections(55%) of 38 sections. Among these sections, 15 sections(71%) were produced rolling noise, 3 sections(14%) squeal noise, 2 sections(10%) braking noise and 1 section(5%) fan noise, and then a main noise source was the rolling noise. In case of downroad line, the highest value section was from Busan Metro Art Museum to Centum city, Motgol to Jigegol by 88 dB(A). The sections of conversation and listening interference(over 80 dB(A)) were 18 sections(47%) of 38 sections. Among these sections, 15 sections(83%) produced rolling noise, 2 sections(11%) squeal noise and 1 section(6%) braking noise were investigated in this study. and then a main noise source was the rolling noise.

Analysis on the Current Status of Maintenance and Monitoring of the Bridge Across Seokdaecheon, Busan Metro Line 4 (부산도시철도 4호선 석대천 횡단 교량의 유지관리계측 현황분석)

  • Woo, Jong-Tae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.349-351
    • /
    • 2022
  • 1차 안전기준은 안전한 공사관리를 위한 목표치이며, 2차 주의기준은 주변구조물이나 주민에게 안전에 영향을 미칠 수 있는 범위 값이며, 3차 정밀분석기준은 공사장 자체의 위험에 대비하는 기준을 의미 하므로 향후에는 계측항목별로 계측관리기준을 세분하여 적용하는 것이 필요하다.

  • PDF

Radionuclides of Ground waters in Busan (부산지역 지하수의 방사성물질 특성)

  • Jeon, Dae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.51-61
    • /
    • 2009
  • This study was performed to research the characteristic of radionuclides of 80 groundwater monitoring networks in Busan. According to the research, average concentration of Uranium was $4.33\;{\mu}g/L$, maximum concentration of Uranium was $171.55\;{\mu}g/L$ among the 80 sampling sites. One sample exceeded the Proposal standard of drinking water in USA in Uranium ($30\;{\mu}g/L$) and four samples exceeded the recommendatory value of WHO about Uranium ($15\;{\mu}g/L$). Radon and gross-$\alpha$ concentration of all samples were far less than the Proposal standard of drinking water in USA. In this study average concentration of radionuclides in underground water wasn't too high, but needed to control the concentration of them to prevent exposure to the people. And it needs to be taken measures in some sites with high concentration of Uranium by closing the pipe line or etc through more studies.

A Study on TPS based on ATO for Driverless LRT (ATO 자동운전 기반의 무인운전 경전철 TPS에 관한 연구)

  • Lee, Chang Hyung;Lee, Jongwoo
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.609-615
    • /
    • 2012
  • TPS (Train Performance Simulation) based on ATO (Automatic Train Operation) is required for driverless LRT (Light Rail Transit) operation plan instead of typical TPS based on driver operation. In this paper, new TPS model using ATO pattern is proposed and compared with the automatic train operation result in a test line of Seoul Metro Line 6 and in a whole line of Busan-Gimhae LRT. The actual ATO pattern can be very accurately simulated by new TPS model with the introduction of 4 parameters such as commercial braking rate, jerk, station stop profile and grade converted distance. The commercial scheduled time for driverless automatic train operation can be proposed to have "Fast" mode TPS trip time plus 3 seconds/km margin recommended by Korean standard LRT specification in this paper.