• Title/Summary/Keyword: C spine AP.

Search Result 13, Processing Time 0.029 seconds

The Study of Effectiveness of Wooden Pillow and Comparison Evaluation of diagnosis method on Straightening of Cervical Curvature Patient (교통사고 후 한방병원에 입원한 일자목증후군 환자를 대상으로 한 진단방법의 비교 평가 및 경침사용의 유효성 연구)

  • Lee, Chiho;Jeon, Donghwi;Lee, Eunjung;Oh, Minseok
    • Journal of Haehwa Medicine
    • /
    • v.24 no.2
    • /
    • pp.1-16
    • /
    • 2016
  • Objectives : This study was designed to evaluate various tools including C-spine X-ray for estimating cervical curvature and identify the effect of wooden pillow on patients diagnosed with straightening of cervical curvature. Methods : This study was carried out on 51 subjects who were encountered traffic accident suffering cervical pain and diagnosed with straightening of cervical curvature by X-ray. 51 subjects were divided into wooden pillow(experimental) group and conservative therapy(control) group. Visual analogue scale, neck disability index and lateral pictures were used and compared after treatment. C-spine AP., Lat. X-ray were used on admission day to calculate cervical curvature and scoliosis by various ways. Results : 4 different measurements of cervical curvature didn't show common results. Both wooden pillow(experimental) group and conservative therapy(control) group showed significant improvement in the visual analogue scale(VAS) and neck disability index(NDI) after hospital treatment. Comparison between center line pictured by lateral view and C-spine Lat. pictured by X-ray showed significant difference in cervical curvature. Lateral deviation of cervical vertebra showed lengthened distance between mastoid process and spinous process of C7. Conclusion : As a result of this research, I found out that various tools for calculating cervical lordosis could derive different results and C-spine AP., Lat X-ray could cause artificial cervical lordosis. According to visual analogue scale(VAS) and neck disability index(NDI) wooden pillow was not effective to reduce pain & disability caused by straightening of cervical curvature. Futhermore, correction effect of straightening of cervical curvature and scoliosis by wooden pillow was weak.

The Study on Static Alignment Classification based on the Full Spine AP X-ray of Adults aged 30-39 (30대 성인의 골반, 척추 및 견갑대 정렬의 패턴 분석 - Full Spine AP X-ray 분석에 따른 -)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.2
    • /
    • pp.89-99
    • /
    • 2010
  • Objectives : This study was designed to analyze the pattern of asymmetrical alignment. Methods : This study was carried out with the data from comprehensive medical testing. 91 subjects aged 30-39 were evaluated by full spine AP X-ray. For pelvis, innominate measurement(IM), off centering measurement(OCM), ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) were analyzed. Spinal curvature and height of shoulder girdle were analyzed. Results : 1. In pelvis, It. posterior-inferior and it. inflare combination pattern was 38 cases(42.8%). 2. In spinal curvature, "reverse S" curve was 45 cases(49.4%) and "reverse C" curve was 30 cases(33%). 3. In shoulder girdle, It. superior pattern was 42 cases(46.1 %) and It. superior pattern was 39 cases(42.9%). 4. In whole body analysis, It. posterior-inferior and It. inflare pelvis, "reverse S" spinal curvature and It. superior shoulder girdle combination patten was 11 cases(12.1 %). This pattern is similar to Kendall's right handedness pattern and Zink's common compensatory pattern. Conclusions : Results from this investigation showed asymmetrical alignment in 30-39 years-old adults. This results are expected to contribute to classifying the alignment pattern in clinic and systemic treatment.

Motor Evoked Potentials Study of the Facilitation and Reciprocal Inhibition Induced by Motor Imagination in the Thumb Muscles (무지근육에서 상상의 운동과 연관된 촉진과 억제에 관한 운동 유발 전위 검사)

  • Yang, Hyun Duk;Son, Il Hong;Suk, Seung Han;Lee, Sung Soo
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.2
    • /
    • pp.187-191
    • /
    • 2003
  • Purpose: MEPs elicited by transmagnetic stimulations of the motor cortex are facilitated by voluntary muscle contraction. We evaluated the effects of the imagination of the movements on latencies of MEPs and reciprocal inhibition by using transmagnetic stimulations. Methods: Twenty two healthy volunteers(eight men and fourteen women) were studied. TMSs were delivered at rest and during imagining abducting or adducting right thumb. A stimulator with a round coil and a fixed intensity of 80% of maximum was used to evoke MEPs. MEPs were evoked by magnetic stimulations over the scalp and cervical spine(C7-T1), and central motor conduction times(CMCT) were calculated by subtracting the latency of compound muscle action potentials(CMAPs) obtained by stimulating over the cervical spine from that obtained by stimulating over the scalp. The motor evoked potentials were recorded from right abductor pollicis brevis muscle(APB) and adductor pollicis muscle(AP) simultaneously. Results: Imagination of abduction resulted in a shortened latency of the CMAPs in APB, and a prolonged latency in AP. Imagination of adduction resulted in a shortened latency in AP, and a prolonged latency in APB. But the imagination caused no significant change in the latency of CMAPs elicited by stimulation over cervical spine. Therefore, the changes of the CMCTs account for these latency changes with imagination of movement. With the imagination of abduction, there are significant reduction of the CMCT's in APB(10.8%) and prolongation in AP(5.8%). On the other hand, with the imagination of adduction, prolongation of the CMCT's in APB(7.3%) and reduction in AP(5.9%) were observed. Conclusion: These findings indicate that imagination of muscle contraction increases the excitability of the human corticospinal system. Reciprocal inhibition may be accountable for the prolonged latency in the antagonist muscle.

  • PDF

The Usefulness of Magnification of the Heart Shadow in Chest Radiography (흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구)

  • Park, Eun-Gyung;Lee, Kun-Young;Jung, Young-Tae;Dong, Kyung-Rae;Ji, Youn-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

Part 4. Clinical Practice Guideline for Surveillance and Imaging Studies of Trauma Patients in the Trauma Bay from the Korean Society of Traumatology

  • Chang, Sung Wook;Choi, Kang Kook;Kim, O Hyun;Kim, Maru;Lee, Gil Jae
    • Journal of Trauma and Injury
    • /
    • v.33 no.4
    • /
    • pp.207-218
    • /
    • 2020
  • The following recommendations are presented herein: All trauma patients admitted to the resuscitation room should be constantly (or periodically) monitored for parameters such as blood pressure, heart rate, respiratory rate, oxygen saturation, body temperature, electrocardiography, Glasgow Coma Scale, and pupil reflex (1C). Chest AP and pelvic AP should be performed as the standard initial trauma series for severe trauma patients (1B). In patients with severe hemodynamically unstable trauma, it is recommended to perform extended focused assessment with sonography for trauma (eFAST) as an initial examination (1B). In hemodynamically stable trauma patients, eFAST can be considered as the initial examination (2B). For the diagnosis of suspected head trauma patients, brain computed tomography (CT) should be performed as an initial examination (1B). Cervical spine CT should be performed as an initial imaging test for patients with suspected cervical spine injury (1C). It is not necessary to perform chest CT as an initial examination in all patients with suspected chest injury, but in cases of suspected vascular injury in patients with thoracic or high-energy damage due to the mechanism of injury, chest CT can be considered for patients in a hemodynamically stable condition (2B). CT of the abdomen is recommended for patients suspected of abdominal trauma with stable vital signs (1B). CT of the abdomen should be considered for suspected pelvic trauma patients with stable vital signs (2B). Whole-body CT can be considered in patients with suspicion of severe trauma with stable vital signs (2B). Magnetic resonance imaging can be considered in hemodynamically stable trauma patients with suspected spinal cord injuries (2B).

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen (경추 추간공 관찰을 위한 촬영법의 고찰)

  • Jeon, Ju-Seob;Eun, Sung-Jong;Kim, Hye-Ran;An, Seung-Hyun;Choi, Nam-Kin;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • The cervical spine of anteroposterior oblique view is essential to observe the intervertebral foramen(IVF). The morphologic changes of IVFs were proved to be abnormal with nerve roots and peripheral structures. The purpose of this study is to evaluate the effective projection angle for observing the IVFs in the Korean adults. In a prospective clinical study of 100 normal persons, $45^{\circ}$, $50^{\circ}$ and $55^{\circ}$ oblique views were compared by measuring the maximal transverse diameter of all the cervical IVFs. $45^{\circ}$ oblique views provided slightly better visualization of upper cervical level(C2-C3, C3-C4, C4-C5), but the lower cervical level(C5-C6, C6-C7, C7-T1) of IVF transverse diameters were substantially increased on the $55^{\circ}$ AP oblique projection. In the comprasion of mean differences between 8 obese person(BMI > 25) and 58 normal person(18.5 < BMI < 22.9) proved to be statistically not significant. Consequently this study shows that $55^{\circ}$AP oblique(tube angle $15^{\circ}$cephalad) view is optimal for evaluating the lower cervical IVFs.

  • PDF

The Study on Relation between Cervical Lateroflexion and Upper Limb Numbness of Patients without Disc Herniation after Traffic Accident (교통사고 이후 디스크 탈출이 없이 상지 저림을 호소하는 환자의 경추 측굴과 상지 저림에 관한 연구)

  • Park, Hyun-Min;Park, Ji-Yong;Kim, Dong-Sub;Kim, Eun-Soo;Kim, Mi-Riong;Cho, Nam-Hoon;Jeong, Hoon;Seong, Ik-Hyun;Kim, Min-Woo;Hong, Nam-Jung;Ha, In-Hyuk;Lee, Jin-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the relation between cervical spine lateroflexion and upper limb numbness after whiplash injury by traffic accident. Methods : Outpatients who visited Jaseng korean medicine hospital after traffic accident took cervical MRI. Patients who had Normal disc and bulging disc were reviewed to measure the cervical lateroflexion by C2-C7 Cobb's angle & scalenus muscle's length through neutrality AP X-ray views. For statistics, we used SPSS version 18.0 for windows. Results : Groups classified into difference of scalenus muscle's length were showen statistical significance than into cobb's angle. Means of numbness group's length difference are $4.18{\pm}2.26mm$ and that of non-numbness group is $1.59{\pm}1.17mm$. Unilateral numbness group had greater angle and longer of length's difference than non-numbness group. Conclusions : The more severe the lateroflexion of the upper extremity numbness occurs well. Group classifed into difference of scalenus muscle's length has more tendency of occurrence of upper limb numbness than that into cobb's angle. And upper limb numbness occurs more frequently at the same direction of lateroflexion.

  • PDF