• 제목/요약/키워드: C2 screw

검색결과 235건 처리시간 0.028초

Posterior Atlantoaxial Fixation with a Combination of Pedicle Screws and a Laminar Screw in the Axis for a Unilateral High-riding Vertebral Artery

  • Kim, Sei-Yoon;Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.141-144
    • /
    • 2007
  • A vertebral arte [VA] injury presents a difficult problem in atlantoaxial fixation. Recent technical reports described posterior C2 fixation using bilateral, crossing C2 laminar screws. The translaminar screw technique has the advantages of producing little risk of VA injury and the unconstrained screw placement. In addition, biomechanical studies have demonstrated the potential of the translaminar screw technique to provide a firmer construct that is equivalent to methods currently used. We report the successful treatment of C1-2 instability with a left-side high-riding VA. Because of the potential risk of VA injury, we performed a posterior C1-2 fixation with a combination of pedicle screws and a laminar screw in C2. We first placed bilateral C1 lateral mass screws and a right-side C2 pedicle screw. However, placement of the left- side C2 pedicle screw was technically difficult due to a narrow isthmus and pedicle. A laminar screw was inserted instead and authors believe that this posterior C1-C2 fixation with a combination of pedicle screws and a laminar screw in C2 can be a useful alternative technique for the treatment of C1-C2 instability in the presence of a unilateral high-riding VA.

Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion : A Preliminary Report

  • Yoon, Sang-Mok;Baek, Jin-Wook;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권2호
    • /
    • pp.120-125
    • /
    • 2012
  • Objective : To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities. Methods : After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft instead of sublaminar wiring. We performed this procedure in thirteen patients who had atlantoaxial instabilities and retrospectively evaluated the bone fusion rate and complications. Results : By using this method, we have achieved excellent bone fusion comparing with the result of other methods without any complications related to this procedure. Conclusion : C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion may be an efficient alternative method to treat various atlantoaxial instabilities.

Modified Trajectory of C2 Laminar Screw-Double Bicortical Purchase of the Inferiorly Crossing Screw

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.119-122
    • /
    • 2008
  • The crossing laminar screw fixation might be the most recently developed approach among various fixation techniques for C2. The new construct has stability comparable to transarticular or transpedicular screw fixation without risk of vertebral artery injury. Quantitative anatomical studies about C2 vertebra suggest significant variation in the thickness of C2 lamina as well as cross sectional area of junction of lamina and spinous process. We present an elderly patient who underwent an occipito-cervical stabilization incorporating crossed C2 laminar screw fixation. We preoperatively recognized that she had low profiles of C2 lamina, and thus made a modification of trajectory for the inferiorly crossing screw. We introduce a simple modification of crossing C2 laminar screw technique to improve stability in patients with low laminar profiles.

Inferolateral Entry Point for C2 Pedicle Screw Fixation in High Cervical Lesions

  • Lee, Kwang-Ho;Kang, Dong-Ho;Lee, Chul-Hee;Hwang, Soo-Hyun;Park, In-Sung;Jung, Jin-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권4호
    • /
    • pp.341-347
    • /
    • 2011
  • Objective : The purpose of this retrospective study was to evaluate the efficacy and safety of atlantoaxial stabilization using a new entry point for C2 pedicle screw fixation. Methods : Data were collected from 44 patients undergoing posterior C1 lateral mass screw and C2 screw fixation. The 20 cases were approached by the Harms entry point, 21 by the inferolateral point, and three by pars screw. The new inferolateral entry point of the C2 pedicle was located about 3-5 mm medial to the lateral border of the C2 lateral mass and 5-7 mm superior to the inferior border of the C2-3 facet joint. The screw was inserted at an angle $30^{\circ}$ to $45^{\circ}$ toward the midline in the transverse plane and $40^{\circ}$ to $50^{\circ}$ cephalad in the sagittal plane. Patients received followed-up with clinical examinations, radiographs and/or CT scans. Results : There were 28 males and 16 females. No neurological deterioration or vertebral artery injuries were observed. Five cases showed malpositioned screws (2.84%), with four of the screws showing cortical breaches of the transverse foramen. There were no clinical consequences for these five patients. One screw in the C1 lateral mass had a medial cortical breach. None of the screws were malpositioned in patients treated using the new entry point. There was a significant relationship between two group (p=0.036). Conclusion : Posterior C1-2 screw fixation can be performed safely using the new inferolateral entry point for C2 pedicle screw fixation for the treatment of high cervical lesions.

Posterior C1-2 Stabilization Using Translaminar Screw Fixation of the Axis

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권5호
    • /
    • pp.387-390
    • /
    • 2006
  • We report a case of C1-2 instability with a bilateral high-riding transverse foramen that was treated with rod-screw fixation using a technique of translaminar rigid screw fixation of the axis. It is believed that a C1-2 fixation with bilateral C-2 translaminar screws has an important advantage over previously reported techniques of C1-2 fixation by eliminating the risk of injury to the vertebral artery during C2 screw placement.

축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증 (The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods)

  • 최준웅;윤승환;박형천;박현선;김은영;하윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

C7 Posterior Fixation Using Intralaminar Screws : Early Clinical and Radiographic Outcome

  • Jang, Sang-Hoon;Hong, Jae-Taek;Kim, Il-Sup;Yeo, In-Sung;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Objective : The use of segmental instrumentation technique using pedicle screw has been increasingly popular in recent years owing to its biomechanical stability. Recently, intralaminar screws have been used as a potentially safer alternative to traditional fusion constructs involving fixation of C2 and the cervicothoracic junction including C7. However, to date, there have been few clinical series of C7 laminar screw fixation in the literature. Thus, the purpose of this study is to report our clinical experiences using C7 laminar screw and the early clinical outcome of this rather new fixation technique. Methods : Thirteen patients underwent C7 intralaminar fixation to treat lesions from trauma or degenerative disease. Seventeen intralaminar screws were placed at C7. The patients were assessed both clinically and radiographically with postoperative computed tomographic scans. Results : There was no violation of the screw into the spinal canal during the procedure and no neurological worsening or vascular injury from screw placement. The mean clinical and radiographic follow up was about 19 months, at which time there were no cases of screw pull-out, screw fracture or non-union. Complications included two cases of dorsal breech of intralaminar screw and one case of postoperative infection. Conclusion : Intralaminar screws can be potentially safe alternative technique for C7 fixation. Even though this technique cannot be used in the cases of C7 laminar fracture, large margin of safety and the ease of screw placement create a niche for this technique in the armamentarium of spine surgeons.

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

환추-축추 불안정성에 있어서 후방 경관절 나사못 고정술에 대한 수술적 경험 (Surgical Experience with Posterior Atlantoaxial Transarticular Screw Fixation in Atlantoaxial Instability)

  • 차승규;유찬종
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.95-100
    • /
    • 2000
  • Objective : Posterior transarticular screw fixation is known to be one of the best surgical method for the atlantoaxial instability. We assessed the complication and operative risk in 15 patients. Patients and Methods : Between January 1997 and April 1998, 15 patients suffering from this condition were admitted to our institution. Atlantoaxial instability was caused by C1 or C2 fractures in 11, rheumatoid arthritis in 2, and os odontoideum in 2. This technique was used in the treatment of 13 patients and 2 patients was used in sublaminar wire fixation only. Bilateral C1-C2 screws were placed in 11 patients ; 2 patients had only one screw placed becauce of an anomalous vertebral artery and axial destruction. Follow-up period ranged from 5 to 20 months. Results : Most screws were positioned satisfactorily. One screw was malpositioned. No patients had neurological complications. Conclusion : Rigidly fixating C1-C2 instability with transarticular screws showed a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the transverse foramen on preoperative computed tomographic scans and by correctly using intraoperative fluoroscopy and surgeon's precaution.

  • PDF