• 제목/요약/키워드: CBEMA Curve

검색결과 18건 처리시간 0.029초

부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법 (Power Quality Index and Cost based on Load-Voltage Characteristics)

  • 이근준
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.213-218
    • /
    • 2003
  • In front of the opening of electric distribution market in 2004, it is indispensable to have a proper estimation of power quality index and rower quality cost calculation mechanism which are indispensable to stabilize highly industrialized society and to vitalize the Investment lot electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and Interruptions which make electric load in unstable operation. This paper suggests power quality index and power quality cost which translate various kinds of voltage records into bus load drop index(BLDI) and bus power quality cost(BPQC) based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power Quality index and costs for utilities and customers requirements.

퍼지 모델을 이용한 배전 계통에서의 순간전압강하 평가 방식 (An Assessment Method for Voltage Sag in Power Distribution System using a Fuzzy Model)

  • 윤상윤;오정환;김언석;김낙경;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, we proposes a method for assessing the effect of voltage sag in power distribution systems using fuzzy model. The proposed method is based on the reliability data of distribution system and specified computer business equipment manufacturer association(SCBEMA) curve that express the representative power acceptability curve by voltage sag for each customer type. The SCBEMA curves are made by using the CBEMA curves obtained from the experiment for the customers sensitive equipment. In order to transform SCBEMA curves to the differential damage by voltage sag, a fuzzy model is used. The proposed fuzzy model is composed to reflect two parameters of customers damage by voltage sag. One is the duration and magnitude of voltage sag and the other is the different risk due to the customer types. The Monte Carlo simulation method and the historical reliability data in KEPCO ae used for case studies.

  • PDF

틸팅열차 운행 중 가선전압 계측 및 분석연구 (The Service Voltage Measurement and Analysis while TTX Runs)

  • 이수길;강철;허재선;김재철;임재찬
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.58-65
    • /
    • 2009
  • 최근 한국철도기술연구원이 개발한 한국형 틸팅열차(TTX) "한빛 200"은 현재 호남선, 중앙선, 충북선 그리고 태백선에서 시험 운행 중에 있다. 본 논문은 TTX가 기존선로에서 시험 운행하는 동안 TTX에 공급되는 전압을 계측 하여 각 기존선로에서 공급하는 전압의 상태를 분석하였다. TTX에 공급되는 전압을 직접 계측하기 위해 TTX의 판토그래프 밑단인 부분에 PT를 설치하여 변압기 1차측 전압을 계측하였다. 정확한 분석을 위해 계측 시 TTX외의 다른 열차와 교차 상황과 주변상황에 대해 기록하였으며, CBEMA 커브를 이용하여 가선전압 상태에 대한 분석을 하였다. 그 결과 호남선, 중앙선, 태백선 모두 정격전압(25[kV])의 110[%]이상의 전압이 200[s]이상 공급되는 구역도 있었으며 빈번하게 110[%]를 초과하고 있는 것으로 분석됐다. 특히 태백선의 가선전압의 상태가 가장 좋지 않은 것으로 분석됐다. 이렇게 가선전압 분석결과는 앞으로 중앙선 및 태백선에 상용화될 TTX의 동력장치 및 전력변환장치를 안정화하는데 도움이 될 것으로 사료된다.

배전계통의 순시전압변동에 의한 수용가측 영향의 현황 분석 (Present State Analysis of Customers' Effect in Power Distribution System by Momentary Voltage Variation)

  • 김재철;윤상윤;오정환;임성정
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.37-46
    • /
    • 1998
  • 본 논문에서는 배전계통에서의 순시전압변동에 의한 수용가측 영향의 현황을 분석하였다. 전력품질에 관한 수용가의 인식은 점차적으로 증대하고 있으며 무엇보다도 전압크기의 품질은 수용기측에 직접적인 영향을 줄 수 있으므로 가장 중요한 전력품질 문제이다. 특히, 자동화공정이 발달함에 따라 순시전압변동은 전자장비, 컴퓨터, 전자개폐기 둥의 민감부하를 가동정지 시키는 심각한 결과를 초래하고 있다. 본 논문에서는 순시전압변동에 의한 수용가측 설비의 정지율을 분석하기위해 전기적 외란에 민감한 부하에 대한 실험을 통해 부하별 CBEMA 곡선과 부하별 누적 CBEMA곡선을 제시하였다. 또한 수용가측 인식실태를 파악하기 위해 "전력품질에 관한 여론조사"를 실시하였으며 그 결과를 수록하였다.

  • PDF

순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;정성원;김재현;이근준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

전압품질이 저압 전기기기 운전에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.33-35
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

신뢰도 데이터를 이용한 배전계통의 순간전압강하 영향평가 (Assessing the Effect of Voltage Sag in Distribution System using Reliability Data)

  • 윤상윤;김재철;임성정;오정환;김두봉;한병덕;김기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.282-285
    • /
    • 1998
  • This paper presents a method to evaluate the effect of voltage sag in distribution system using the component reliability data of utilities. The proposed method is based on Specified CBEMA curve which is the probability curve of the customers' effect by voltage sag. We carried out the experiment for the customers' sensitive equipments using the test facilities in KERI. The Monte Carlo method and the historical reliability data in KEPCO are used for simulations.

  • PDF

컴퓨터 응용 부하들을 위한 전압 외란 검출 방법 (A Voltage Disturbance Detection Method for Computer Application Lods)

  • 이상훈;최재호
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.584-591
    • /
    • 2000
  • 컴퓨터와 같은 민감한 부하를 전압강하나 정전과 같은 전원 장애로부터 보호하기 위하여 전력보상장치가 설­치되어 왔다. 전력보상장치의 경우 계통과의 연계를 위해 대부분 정지형 스위치를 이용하고 있으며, 이러한 정지형 스위치의 전환동작은 매우 중요한 부분을 차지하고 있다. 그간 전략보상장치의 구조나 제어에 관한 연구는 활발하게 진행되어 왔으나 전력보상장치의 운전을 시작하기 위한 전원 장애의 감지에 판한 연구는 매우 드문게 현실이다. 따라서 본 논문에서는 정지형 스위치 절환동작을 위해 CBEMNITIC 커브를 이용하여 컴퓨터 응용부하판 위한 새보운 전원 장애 검출 암고리즘을 제안한다. 제안된 검출 알고리즘은 동기 좌표계에서 직류 값으으 변환된 삼상 순시 전압값을 동작 기준값과 비교하는 방법을 사용하여 빠른 검출 시간을 가지도록 하였다. 그리고, 간단한 1차 디지텔 필터를 삽입하여 잡음에 강인하도록 선거하였다. 이러한 필터에 의해 나타나는 위상지연 및 이득감소를 각각 전달함수를 이용한 수식적인 해석과 오차의 정규화를 통해 보상하였다. 마지막으로 ACSL를 이용한 시뮬레이션파 실험을 통해 제안된 알고리즘의 타당성을 입증하였다.

  • PDF

순간전압강하에 대한 비선형 저압전기기기의 동적특성 (A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag)

  • 이현철;정성원;김재현;이근준
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

퍼지 위험도 평가 모델을 이용한 배전계통의 순간전압강하 영향 평가 (Assessing the Effect of Voltage Sag in Distribution System Using a Fuzzy Risk Assessment Model)

  • 윤상윤;오정환;한병덕;김재철;박중신;임동균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1085-1087
    • /
    • 1999
  • In this paper, we propose the method for assessing the effect of voltage sag in power distribution system using fuzzy risk assessment model. The proposed method is based on SCBEMA curve that expresses the representative susceptibility curve by voltage sag for each customer type. These corves are made using the CBEMA curves obtained from the experiment for the customers'sensitive equipment. In order to transform SCBEMA curves to the probability damage by voltage sag, the fuzzy risk assessment model is used in this paper. Case studies were performed to analyze the effect of voltage sag by varying parameters. The Monte Carlo simulation method and the historical reliability data in KEPCO are used for case studies.

  • PDF