• Title/Summary/Keyword: CCD camera

Search Result 1,427, Processing Time 0.025 seconds

A Study on the CCD Camera Calibration for Close-Range Photogrammetry (근거리 사진측량을 위한 CCD 사진기 검정에 관한 연구)

  • Yeu, Bock-Mo;Lee, Seok-Kun;Choi, Song-Wook;Kim, Gi-Hong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.5 no.1 s.9
    • /
    • pp.159-165
    • /
    • 1997
  • Because CCD camera acquires the digital images without separate processing, its availabilities are increased. In this study, for CCD camera calibration DLT equation and radial or decentering distortion equation are combined and the calibration parameters are calculated using three dimensional test model. The digital images acquired by CCD camera are matched using coefficient of correlation and the three dimensional coordinates of objects are determined. Also, the potential usefulness of CCD camera in close range photogrammetry is examined.

  • PDF

Calibration Method of Plenoptic Camera using CCD Camera Model (CCD 카메라 모델을 이용한 플렌옵틱 카메라의 캘리브레이션 방법)

  • Kim, Song-Ran;Jeong, Min-Chang;Kang, Hyun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.261-269
    • /
    • 2018
  • This paper presents a convenient method to estimate the internal parameters of plenoptic camera using CCD(charge-coupled device) camera model. The images used for plenoptic camera calibration generally use the checkerboard pattern used in CCD camera calibration. Based on the CCD camera model, the determinant of the plenoptic camera model can be derived through the relationship with the plenoptic camera model. We formulate four equations that express the focal length, the principal point, the baseline, and distance between the virtual camera and the object. By performing a nonlinear optimization technique, we solve the equations to estimate the parameters. We compare the estimation results with the actual parameters and evaluate the reprojection error. Experimental results show that the MSE(mean square error) is 0.309 and estimation values are very close to actual values.

Low Cost Digital X-Ray Image Capture System Using CCD Camera (CCD 카메라를 사용한 저가형 Digital X-Ray 영상취득 시스템)

  • Kang, Yong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.19-22
    • /
    • 2007
  • We developed a low cost digital X-Ray image capturing system using a CCD camera, instead of using the high cost image plate and image intensifier. In order to reduce the system volume, we directly made the dark box shorter than the previous model. Using the graphic language, we developed a program in order for post-processing the images captured by the CCD camera. This program improves the image resolving power.

A DSP Circuit Design on Improvement of Video Signal With High Sensotivity CCD Sensor Camera (고감도 CCD센서 카메라의 영상신호 성능향상을 위한 DSP 회로 설계)

  • Park, Jae-Chul;Kim, Yong-Deak
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.331-332
    • /
    • 2007
  • This Paper deals with the high sensitive camera circuit design, which is more sensitive than those on the market now in a way that it got rid of chronic smearing problem in CCD sensor and other kinds of noises in video signal effectively. This paper focused on the principle of CCD and video signal process and analyzed the specialized technique of industry and fundamental high sensitivity of CCTV camera. 1 also looked into the SONY super-HAD CCD camera which is very popular in the field now and compared this with the SONY EXview CCD camera to analyze the picture improvement using video test equipment. For the result, it had 190mv on camera sensitivity, 14dB on smearing, and 2dB on signal to noise ratio.

  • PDF

THE BOES CCD CAMERA 1. CAMERA ASSEMBLY (BOES CCD 카메라 1. 카메라 구성)

  • Park, B.G.;Jang, J.G.;Seong, H.C.;Jang, B.H.;Kim, K.M.;Han, I.
    • Publications of The Korean Astronomical Society
    • /
    • v.18 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • A CCD camera for the BOES (Bohyunsan Observatory Echelle Spectrograph) has been developed. The camera consists of a 2048 ${\times}$ 4096 format CCD, a SDSU Gen-I CCD controller, and a continuous flow cryostat (CFC) designed by the ESO. In order to control the CCD under SDSU Gen-I controller, the voltage level of all the biases and clocks were lowered by -6V. The CFC showed cooling time of about 10 hour, after which the chip temperature settled down with variation less than ${\pm}1^{\circ}C$. The final chip temperature is around -105$^{\circ}C$ with the setting value for the CFC as -170$^{\circ}C$.

Accuracy of Close-Range Industrial Photogrammetry Using CCTV Type CCD Camera (CCTV유형 CCD 카메라를 이용한 근거리 산업사진측량의 정확도)

  • 이진덕;최용진
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.3
    • /
    • pp.283-290
    • /
    • 2001
  • This paper demonstrates the performance of industrial precise measurement using the digital close-range photograrmmetric system based on a off-the-shelf CCTV-type CCD camera. The system was constructed with a CCD camera and a PC with a frame grabber, coupled with digital image mensuration and self-calibrating bundle adjustment techniques. An artificial fish reef with cubic shape was taken as an object for the application test of the system and the digital images were acquired on multi-station convergent network around the object. The geometric calibration of the CCD camera and the phototriangulation of the entire surface of the object was carried out simultaneously by means of self-calibrating bundle adjustment technique. Also the system comprising a high resolution still-video camera Kodak DCS, which high accuracy potential has been already established, were employed in similar network condition. Then the results from two different camera systems were compared in the accuracies of phototriangulation.

  • PDF

Target Tracking System for an Intelligent Wheelchair Using Infrared Range-finder and CCD Camera (적외선 레인지파인더와 CCD 카메라를 이용한 지능 휠체어용 표적 추적 시스템)

  • Ha Yun-Su;Han Dong-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.560-570
    • /
    • 2005
  • In this paper, we discuss the tracking system for a wheelchair which can follow the path of a human target such as a nurse in hospital. The problem of human tracking is that it requires recognition of feature as well as the tracking of human positions. For this purpose the use of a high cost visual sensor such as laser finder or streo camera makes the tracking a high cost additional expense. This paper proposes the tracking system uses a low cost infrared range-finder and CCD camera, The Infrared range-finder and CCD camera can create a target candidate through each target recognition algorithm. and this information is fused in order to reduce the uncertainties of a target decision and correct the positional error of the human. The effectiveness of the proposed system is verified through experiments.

Focus Control for CCD Camera using Annealing Algorithm (어닐링 알고리즘을 이용한 CCD 카메라 초점 제어)

  • 이관용;임신영;조성원
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.5
    • /
    • pp.459-465
    • /
    • 2000
  • In this paper, we propose a method for controlling camera focus in the short distance by analyzing NTSC signal of a CCD camera. When the distance between a camera and an object is less than about 1 meter, the existing CCD cameras with auto-focusing function are hard to acquire the proper images because they focus on the protruding minute parts ofthe object without taking into account the whole state of the object. To solve such a problem, we use an annealing algorithm to control the motor of a camera by analyzing the overall signal obtained from the camera. By doing so, we can acquire the adequate images at the near distance. The proposed method will be used for a personal identification system by human iris patterns.

  • PDF

A System for Estimating Height of Person Using Single CCD Camera (단일 CCD 카메라를 이용한 신장 인식 시스템 개발)

  • Cho, Do-hyeoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.145-149
    • /
    • 2017
  • Considering the various user height, we develop a low-cost multimedia electronic podium system for height adjustment. In order to recognize the user utilizes height of a single CCD camera and the ultrasonic sensor. It estimates the height from the user of the image obtained by the CCD camera. Also it uses renal region division method from the image recognition in order to effectively estimated. According to the estimated height, we implemented the control system for the height control of the electronic podium.

High Fidelity Color Capturing of CCD-Camera System by Using of Spectral Sensitivity Model (스펙트럼 특성 모델을 이용한 CCD카메라 시스템의 고성능 칼라 Capturing)

  • 이상진;신윤철;김일도;김문철
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1751-1754
    • /
    • 2003
  • CCD Camera System으로 capture 한 image를 표준 display장치로 재현할 때 capture 할 당시의 원 피사체의 모습을 그대로 재현하여야만 한다. 그러나 일반 consumer 용 camera system의 CCD channel spectral sensitivity 특성이 인간의 spectral sensitivity(1(λ), m(λ), 5(λ)) 특성과 일치하지 않고, linear transform의 관계도 성립하지 않음으로써 capturing시 근본적인 color error가 발생하게 된다. 기존의 CCD Camera System 에서는 CCD sensor 의 color 정보와 display 장치의 color 정보와의 단순한 산술적인 관계로 color를 재구성하는 방법을 사용하고 있어 원 피사체의 color 를 그대로 재현할 수가 없다. 본 논문에서 제시하는 알고리즘은 CCD 의 channel spectral sensitivity특성 과 CIE-color matching function과의 관계를 고려하여 color를 재구성함으로써 color error를 줄이도록 하였다 제시된 알고리즘의 color error를 검증하기 위하여 물체의 고유반사율을 알고 있는 AGFA IT8.7-2 test chart(283 spectra), Dupont Paint Chips(120 spectra), Mcbeth Color Checker(64 spectra) 및 Natural Objects(170 spectra) 등 다양한 objects spectra(637 spectra) [1][2]를 이용하여 기존 방법의 알고리즘과 비교하여 보았다.

  • PDF