• Title/Summary/Keyword: CMRR

Search Result 31, Processing Time 0.03 seconds

Comparison between a differential and a non-differential amplifier system with two electrodes in bio-potential measurement (생체 전위 측정에서 2-전극 차동 증폭 시스템과 2-전극 비차동 증폭 시스템의 비교)

  • Kang, Dae-Hun;Lee, Chung-Keun;Lee, Sang-Joon;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1977-1978
    • /
    • 2008
  • In this paper, we compare performance of common-mode rejection between a differential and a non-differential amplifier system with two electrodes. A differential amplifier system is constant for common-mode rejection ratio(CMRR) on the frequency domain. But a non-differential amplifier's CMRR is determined by $Z_{FB}/Z_e$ ($Z_{FB}$ ; feedback impedance, $Z_e$; electrode impedance). There is trade-off between a non-differential amplifier's CMRR and its differential input impedance. And a non-differential amplifier system has some advantages for a bio-potential measurement with two electrodes because a designer can control the impedance between the body and system's common.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Design of BiCMOS Signal Conditioning Circuitry for Piezoresistive Pressure Sensor (압저항형 압력센서를 위한 BiCMOS 신호처리회로의 설계)

  • Lee, Bo-Na;Lee, Moon-Key
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.25-34
    • /
    • 1996
  • In this paper, we have designed signal conditioning circuitry for piezoresistive pressure sensor. Signal conditioning circuitry consists of voltage reference circuit for sensor driving voltage and instrument amplifier for sensor signal amplification. Signal conditioning circuitry is simulated using HSPICE in a single poly double metal $1.5\;{\mu}m$ BiCMOS technology. Simulation results of band-gap reference circuit showed that temperature coefficient of $21\;ppm/^{\circ}C$ at the temperature range of $0\;{\sim}\;70^{\circ}C$ and PSRR of 80 dB. Simulation results of BiCMOS amplifier showed that dc voltage gain, offset voltage, CMRR, CMR and PSRR are outperformed to CMOS and Bipolar, but power dissipation and noise voltage were more improved in CMOS than BiCMOS and Bipolar. Designed signal conditioning circuitry showed high input impedance, low offset and good CMRR, therefore, it is possible to apply sensor and instrument signal conditioning circuitry.

  • PDF

Design of High Gain Differential Amplifier Using GaAs MESFET's (갈륨비소 MESFET를 이용한 고이득 차동 증폭기 설계)

  • 최병하;김학선;김은로;이형재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.8
    • /
    • pp.867-880
    • /
    • 1992
  • In this paper, a circuit design techniques for Improving the voltage gain of the GaAs MESFET single amplifier is presented. Also, various types of existing current mirror and proposed current mirror of new configuration are compared. To obtain the high differential mode gain and low common mode gain, bootstrap gain enhancement technique Is used and common mode feedback Is employed In the design of differential amplifier. The simulation results show that designed differential amplifier has differential gain of 57.66dB, unity gain frequency of 23.25GHz. Also, differential amplifier using common mode feedback with alternative negative current mirror has CMRR of 83.S8dB, stew rate of 3500 V /\ulcorners.

  • PDF

Design and Fabrication of an Aluminum-Gate PMOS Differential Amplifier (알루미늄 게이트 PMOS 차동증폭기의 설계 및 제작)

  • 신장규;권우현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.1
    • /
    • pp.14-19
    • /
    • 1982
  • A differential amplifier has been designed and fabricated using aluminum-gate PMOS technology, Only enhaneement-mode MOSFET's are used in the circuit and the dimensions of transistors have been determined using simulation program MSINC. The fabricated integrated circuit with +15V and -l5V power supplies shows an open-loop DC voltage gain of 42 dB, a common mode rejection ratio (CMRR) of 50 dB, and a Power consumption of 20mW.

  • PDF

Implementation of an analog front-end for electroencephalogram signal processing (뇌전도 신호 처리용 아날로그 전단부 구현)

  • Kim, Min-Chul;Shim, Jae Hoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper presents an analog front-end for electroencephalogram(EEG) signal processing. Since EEG signals are typically weak and located at very low frequencies, it is imperative to implement an amplifier with high gain, high common-mode rejection ratio(CMRR) and good noise immunity at very low frequencies. The analog front-end of this paper consists of a programmable-gain instrumentation amplifier and a band-pass filter. A frequency chopping technique is employed to remove the low-frequency noise. The circuits were fabricated in 0.18um CMOS technology and measurements showed that the analog front-end has the maximum gain of 60dB and >100dB CMRR over the programmable gain range.

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

KMTNet 18k Mosaic CCD Camera System Performance Improvement and Maintenance (외계행성 탐색시스템 18k 모자이크 CCD 카메라 시스템 성능개선 및 유지보수)

  • Cha, Sang-Mok;Lee, Chung-Uk;Kim, Seung-Lee;Lee, Yongseok;Atwood, Bruce;Lim, Beomdu;O'Brien, Thomas P.;Jin, Ho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2018
  • 외계행성 탐색시스템 18k 모자이크 CCD 카메라는 4개의 9k CCD로 구성되며 총 32개 채널의 영상영역과 리드아웃 회로를 가진다. 관측 영상에는 각 영상영역에 대한 오버스캔(overscan) 영역이 포함되는데, 영상 신호에 의한 오버스캔 영역의 바이어스(bias) 교란을 최소화하기 위해 리드아웃 회로의 인버팅 앰프에 대한 Common Mode Rejection Ratio(CMRR)를 미세 조정하였다. 그 결과 세 사이트의 평균 CMRR이 55 dB에서 73 dB로 향상되었고, 기존에는 영상 신호에 따른 오버스캔 바이어스 레벨의 선형적 관계가 약 2/1,000의 기울기를 가졌으나 조정 후에는 약 2/10,000로 바이어스 오차가 줄어들었다. CCD 리드아웃 회로의 미세조정과 클락(clock) 개선을 통해 물결무늬 잡음 제거 및 읽기 잡음 감소가 이루어졌으며, 향후의 추가적인 바이어스 안정화와 크로스톡 개선 방안이 검토되고 있다. 카메라 전자부 조정 과정 및 결과와 더불어, 카메라 듀어와 부대장비 유지보수, Polycold CryoTiger 냉각기 운영 및 개선 관련 노하우도 함께 발표한다.

  • PDF

A 1V 200-kS/s 10-bit Successive Approximation ADC

  • Uh, Ji-Hun;Kim, Sang-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.483-485
    • /
    • 2010
  • A 200kS/s 10-bit successive approximation(SA) ADC with a rail-to-rail input range is proposed. The proposed SA ADC consists of DAC, comparator, and successive approximation register(SAR) logic. The folded-type capacitor DAC with the boosted NMOS switches is used to reduce the power consumption and chip area. Also, the time-domain comparator which uses a fully differential voltage-to-time converter improves the PSRR and CMRR. The SAR logic uses the flip-flop with a half valid window, it results in the reduction of the power consumption and chip area. The proposed SA ADC is designed by using a $0.18{\mu}m$ CMOS process with 1V supply.

  • PDF

The Design of High Precision Pre-amplifier for EEG Signal Measurement (뇌파신호 측정을 위한 고정밀 전치 증폭기의 설계)

  • 유선국;김남현
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 1995
  • A high-precision pre-amplifier is designed for general use in EEG measurement system. It consists of signal generator, signal amplifier with a impedance converter, shield driver, body driver, differential amplifier, and isolation amplifier. The combination of minimum use of inaccurate passive components and the appropriate matching of each monolithic amplifiers results in good noise behavior, low leakage current, high CMRR, high input impedance, and high IMRR. The performance of EEG pre-amplifier has been verified by showing the typical EEG pattevn of a nomad person through the clinical experiments.