• Title/Summary/Keyword: CO2%28Carbon dioxide%29

Search Result 9, Processing Time 0.028 seconds

Reconstructing Atmospheric CO2 Concentration Using Its Relationship with Carbon Isotope Variations in Annual Tree Ring of Red Pine

  • Choi, Woo-Jung;Lee, Kye-Han;Lee, Sang-Mo;Lee, Seung-Heon;Kim, Han-Yong
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.4
    • /
    • pp.362-366
    • /
    • 2010
  • Carbon isotope ratio ($^{13}C/^{12}C$, expressed as ${\delta}^{13}C$) of tree ring can be proxy of atmospheric $CO_2$ concentration ([$CO_2$]) due to the inter-correlation between atmospheric [$CO_2$], ${\delta}^{13}C$ of atmospheric $CO_2$, and ${\delta}^{13}C$ of plant tissue that assimilates atmospheric $CO_2$. This study was conducted to investigate if ${\delta}^{13}C$ of tree ring of Pinus densiflora in polluted area may show a lower value than that in unpolluted area and to explore the possibility of reconstructing atmospheric [$CO_2$] using its relationship with ${\delta}^{13}C$ of tree ring. During the period between 1999 and 2005, ${\delta}^{13}C$ of tree annual ring tended to decrease over time, and the ${\delta}^{13}C$ in polluted area (-27.2‰ in 2009 to -28.3‰ in 2005) was significantly (P<0.001) lower than that (-26.0‰ in 1999 to -27.1‰ in 2005) in unpolluted area. This reflects a greater emission of $CO_2$ depleted in $^{13}C$ in the polluted area. Atmospheric [$CO_2$] was significantly (P<0.01) correlated with ${\delta}^{13}C$ of tree ring in a linear fashion. Using the linear regression equation, atmospheric [$CO_2$] in the polluted area was estimated to range from 392.3 ppm in 1999 to 410.9 ppm in 2005, and these values were consistently higher than the national atmospheric [$CO_2$] monitored at the Anmyoundo meteorological station (from 370.7 ppm in 1999 to 387.2 ppm in 2005). Our study suggested that it is possible to reconstruct atmospheric [$CO_2$] in a certain area using the relationship between tree ring ${\delta}^{13}C$ and atmospheric [$CO_2$].

SynGas Production from Propane using GlidArc Plasma Reforming (부채꼴방전 플라즈마 개질을 이용한 프로판으로부터의 합성가스 생산)

  • Song, Hyoung-Oon;Chun, Young-Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.323-328
    • /
    • 2006
  • The purpose of this paper was to investigate the reforming characteristics and optimum operating condition of the GlidArc-assisted $C_3H_8$ reforming reaction for the synthesis gas(SynGas) production without formation of carbon black from propane using GildArc plasma reforming. Also, in order to increase the hydrogen production and the propane conversion rate, 13 wt % nickel catalyst was filled into the catalytic reactor and parametric screening studies were conducted, in which there were the variations of vapor mole ratio$(H_2O/C_3H_8),\;CO_2$ mole ratio($CO_2/C_3H_8$), input power and injection flow rate. When the variations of vapor mole ratio, $CO_2$ mole ratio, input power and injection flow rate were 1.86, 0.48, 1.37 kW and 14 L/min, respectively, the conversion rate of the propane reached its most optimal condition, or 62.6%. Under the condition mentioned above, the dry basic concentrations of the SynGas were $H_2\;44.4%,\;CO\;18.2%,\;CH_4\;11.2%,\;C_2H_2\;2.0%,\;C_3H_6\;1.6%,\;C_2H_4\;0.6%\;and\;C_3H_4$ 0.4%. The conversion rate of carbon dioxide was 29.2% and the concentration ratio of hydrogen to carbon monoxide($H_2/CO$) in the SynGas was 2.4.

Qualitative Changes in Grafted Cactus Cultivars during Simulated Transportation (모의운송시 접목선인장의 품종별 품질변화)

  • Yoon, Jung-Han;Song, Jong-Eun;Byoun, Hye-Jin;Park, Ju-Hyun;Kim, Young-Ho;Son, Ki-Cheol
    • Horticultural Science & Technology
    • /
    • v.29 no.6
    • /
    • pp.575-582
    • /
    • 2011
  • This experiment was conducted to study the qualitative changes of grafted cactus after harvest and to examine the decomposition characteristics of pathogenic fungi which occurs or grows during the simulated shipping period. Plant materials with four varieties of Gymnocalycium mihanovichii var. friedrichii including, 'Hukwang', 'Huhong', 'Hwangwol', 'Yeunhwa' and two varieties of Chamaecereus silvestrii f. variegate such as 'Goldcrown' and 'Yellowcrown' were used. During the simulated shipping period, the fresh-weight, bulb diameter, carbon dioxide emission rate, and decomposition rate were observed. The regeneration rate and decomposition rate were observed for the grafted cactuses that were placed in a greenhouse environment with a temperature of $28{\pm}12^{\circ}C$ and humidity of $36{\pm}15.3%$ after 40 days of simulated shipping. There were reductions in the fresh-weight and bulb diameter in every variety as time passed while the carbon dioxide emission rate showed no meaningful difference by each variety. Furthermore, the decomposition rate in the scion was higher than in the stock. According to the analysis of pathogenic fungi by decomposition characteristics, Alternaria sp., Cladosporium sp., Colletotrichum sp., Fusarium sp., Penicillium sp. in G. mihanovichii var. friedrichii were found and Alternaria sp., Bipolaris sp., Cladospoirum sp. in C. silvestrii f. variegate were identified. Therefore, to maintain and improve the quality of grafted cactus, it is necessary to analyze the factors of decomposition from the time of harvest until the point of export and develop a process technology to minimize the decomposition rate.

The Study of Indoor Air Quality at Schools in Chung-Nam Area (충남 지역 학교의 실내공기질에 관한 연구)

  • Cho, Tae-Jin;Choi, Han-Seam;Jeon, Young-Taek;Lee, Che-Won;Lee, Jong-Dae;Jou, Hye-Mee;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.501-507
    • /
    • 2008
  • The concentrations of HCHO(formaldehyde), $PM_{10}$(particulate matter), $CO_2$(carbon dioxide) and TBC(total bacteria counter) distribution in schools(Chung-Nam Area) were examined, and the results were compared with the recommended criterion of the administration law of indoor air. The subjects were an elementary school, a middle school and a high school in Chung-Nam area, and the concentration of TBC was examined by Single Stage Air Cascade Sampler, which applied the inertia collision catching method of 28.29L/min(flux) during 5 months from March, 2007 to July, 2007. The instrument(LD-3B, SIBATA Company)was used to examine $PM_{10}$, by a light scattering method and a light transmission method. The instrument(Airboxx(KD Engineering) was used to examine $CO_2$. The instrument(Z300XP(Environmental sensor)was used to examine HCHO. The result indicated that the $PM_{10}$ average concentrations of the surveyed classrooms were $49{\mu}g/m^3$ in Spring and $59{\mu}g/m^3$ in Summer. The $CO_2$ average concentration of the surveyed schools were 576 ppm in the classroom and 527 ppm in the stateroom. The average concentration of TBC were $729CFU/m^3$ in an elementary school, $401CFU/m^3$ in a middle school, $381CFU/m^3$ in a high school. The HCHO average concentration of the surveyed schools were 0.03 ppm in the classroom, 0.02 ppm in the stateroom.

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF

Comparison of Blood Gas, Biochemical Factors, and Hormone Concentrations, and Muscle Stress Response Factors of Chickens in General Farms and Animal Welfare Farms (일반농장과 동물복지농장 닭의 혈액 내 gas, 생화학인자, 호르몬 농도 및 근육 내 스트레스 반응인자 비교)

  • Kim, Hee-Eun;Park, Jin-Ryong;Lee, Jeong-Eun;Kang, Da-Rae;Jang, Ae-Ra;Choe, Ho-Sung;Shim, Kwan-Seob
    • Korean Journal of Organic Agriculture
    • /
    • v.29 no.3
    • /
    • pp.415-427
    • /
    • 2021
  • It is generally recognized that high stocking density can increase the risk of immune dysfunction and reduction in productivity cause of elevated stress in broiler farm. The domestic livestock industry is implementing a certification system for animal welfare and livestock farms to reduce the problem of dense breeding. This study compared broiler from the general farm and animal welfare farm to confirm the effectiveness of animal welfare farms against stress. Gas concentrations in a farm of general and animal welfare farms were analyzed, blood (n=10) of the 28-day-old broiler was collected, the partial pressure of the gas in the blood was analyzed using whole blood, and biochemical factors and hormones were analyzed using the serum. Glycogen and L-lactate are analyzed using ELISA kit on finely pulverized muscles (n=10). CO2 and NH3 levels in the farm were significantly higher in general farm. Partial carbon dioxide tension (PCO2) in blood was significantly higher and partial oxygen tension (PO2) was significantly lower in the general farm. Creatinine (CREA), glucose (GLU), aspartateaminotransferase (AST), and creatinekinase (CK) in the blood were significantly higher in the general farm, and total protein (TP) and globulin (GLOB) were significantly higher in animal welfare farm. Blood corticosterone and norepinephrine were significantly higher in general farm and epinephrine was significantly higher in animal welfare farm. These results imply that animal welfare farm provides a stress-reduced breeding environment.

Utilization of Egg-shell for Bread-making (제빵시 난각의 이용에 관한 연구)

  • Kim, Joong-Man;Kim, Yong-Seob;Yang, Hee-Chon;Choi, Yong-Bae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.18 no.2
    • /
    • pp.160-166
    • /
    • 1989
  • This study was conducted to investigate whether egg-shell may be used as a mineral sourceor leavening agent in breadmaking. In Korea the waste volume of egg shell has been estimated at about 28,694 tons per year. Carbon dioxide generation maxima were established for barking powder$(153{\pm}3ml/g)$, egg-shell(205in reaction with lactic acid) and yeast$(115{\pm}3ml/sugar\;g)$. Gas release time required for each substance to reach $CO_2$ maximum was, for baking powder 7 minutes, for egg-shell 45 mins and for yeast 240 mins. Particle size of egg-shell in breadmaking was suitable more than 20 mesh (-). When egg-shell only was added to the basic formular without including lactic acid, no leavening effect was observed. However, when lactic acid and egg-shell were used together, the leavening effect was more or less equivalent to that of yeast(control). Addition of egg-shell was found to increase calcium content of bread products without noticeable altering flavor, as compared with control. Joint use of egg-shell was organic acids in breadmaking was shown to have potential in time saving, volume increase and yeast saving.

  • PDF

The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass (체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.712-723
    • /
    • 2002
  • Substantial alterations in cerebral blood flow(CBF) are known to occur during cardiopulmonary bypass(CPB). Many investigators have speculated that these changes may be responsible for both minor and major cerebral damages after CPB. More recently, these changes in CBF have been observed to be intimately related to the arterial carbon dioxide tension(Pa$CO_2$) maintained during CPB. The present study was prospectively designed to investigate the clinical effects of normocapnic and hypercapnic CPB on the cerebral oxygen metabolism in cardiac surgery Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to either normocapnic group (Pa$CO_2$35~40 mmHg, n=18) or hypercapnic group(Pa$CO_2$, 45~55 mmHg, n=18) with moderately hypothermic nonpulsatile CPB(nasopharyngeal temperature of 29~3$0^{\circ}C$). In each patient, middle cerebral artery blood flow velocity( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), cerebral oxygen extraction(COE), cerebral metabolic rate for oxygen(CMR $O_2$), cerebral oxygen transport( $T_{E}$ $O_2$), $T_{E}$ $O_2$/CMR $O_2$ ratio, cerebral desaturation(internal jugular bulb blood oxygen saturation $\leq$ 50%), and arterial and jugular bulb blood gas were evaluated throughout the operation. Postoperative neuropsychologic complications were assessed in all patients. All variables were compared between the two groups. Result: VMCA(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), TE $O_2$(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), $T_{E}$ $O_2$,/CMR $O_2$ ratio(287.38$\pm$28.051 vs 246.77$\pm$25.84), $O_2$ tension in internal jugular bulb (41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), and $O_2$saturation in internal jugular bulb(68.97$\pm$10.96 vs 58.12$\pm$12.11%) during CPB were significantly lower in normocapnic group(p=0.03), whereas hypercapnic group had lower C(a-v) $O_2$(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), COE(0.3$\pm$0.03 vs 0.4$\pm$0.03), CMR $O_2$(5.8 $\pm$0.5 vs 6.8$\pm$0.6), and arterial blood pH(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04) during CPB. Hypercapnic group had lower incidence of cerebral desaturation than normocapnic group(3 vs 9 patients, p=0.03). Duration of the neuropsychologic complication(delirium) were shorter in hypercapnic group than in normocapnic group(36 vs 60 hrs, p=0.009). Conclusion: These findings suggest that hypercapnic CPB may have salutary effects on the cerebral oxygen metabolism and postoperative neurologic outcomes in cardiac surgery.surgery.

A Study on Public Nuisance in Kwangju City (Survey on Air Pollution and Noise Level) (공해(公害)에 관(關)한 조사연구(調査硏究) -광주시(光州市)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 조사연구(調査硏究)-)

  • Chung, Yo-Han;Kim, Kil-Wng;Moon, Jae-Kyu;Jhoo, Heung-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1972
  • During the period from June 1st 1971 to November 30 th 1971, studies on air pollution were made in Kwangju city. The city was divided into 6 areas; the downtown area, the semi-downtown area, the heavy traffic area, the commercial area, the residential area, the park area, 13 surveying sites were selected each representing the characteristics of the area. The Measurement methods which were used are described below. Sulfur oxides were measured by $PbO_2$ cylinder method, sulfur dioxides ($SO_2$) and carbon monoxide (CO) by the MSA & Kitakwa detector, dustfall by the Deposit gauge method, and the noise levels by the Kanomax soundlevel meter. The results obtained are as follows: 1. The mean value of sulfur oxides in Kwangju city was $1.16mg\;SO_3/day/100cm^2\;PbO_2$, ranging from $0.45mg\;SO_3/day/100cm^2\;PbO_2$ to $3.10mg\;SO_3/day/100cm^2\;PbO_2$. 2. The mean values of sulfur oxides according to its specific area in the city were $1.45mg\;SO_3/day/100cm^2\;PbO_2$ in heavy traffic area, 1.36 in downtown area, 1.23 in semi-downtown area, 1.11 in commercial area, 0.96 in residential area, and 1.07 in park area, respectively. 3. The average concentration of sulfur dioxide was 0.063 ppm from 2 to 5 P.M in Kwangju city. 4. The average concentrations of sulfur dioxides according to its specific area, from 2 to 5 P.M, in the city were 0.084 ppm in heavy traffic area & downtown area, 0.067 in commercial area, 0.053 in semi-downtown area, 0.052 in residential area, and 0.036 in park area. 5. The average concentration of carbon monoxide was 22.3 ppm from 2 to 5 P.M, in Kwangju city. 6. The average concentrations of carbon monoxide according to its specific area, from 2 to 5 P.M, in the city were 27.0 ppm in downtown area, 26.3 in semi-downtown area, 23.0 in heavy traffic area, 21.7 in commercial area, 20.0 in residential arera, and 17.6 in park area. 7. The mean value of dusifall in Kwangju city was $29.28ton/km^2/month$, ranging from $9.85ton/km^2/month$ to $66.34ton/km^2/month$. 8. The mean values of dustfall according to its specific area in the city were $50.37ton/km^2/month$ in semi-downtown area, 42.76 in heavy traffic area, 34.67 in downtown area, 17.77 in commercial area, 14.40 in park area, and 14.76 in residential area. 9. The mean values of the soluble dust in Kwangju city was $10.23ton/Km^2/month$ and that of the insoluble dust was $19.05ton/Km^2/month$. 10. The mean value of noise level in Kwangju city was 62 phon, ranging from 37 phon to 88 phon. 11. The mean values of noise level according to its specific area in the city were 76 phon in heavy traffic area, 67 in semi-downtown area, 64 in downtown area, 59 in commercial area, 52 in part area, and 50 in residential area.

  • PDF