A Study on the Assembly Process and Reliability of COF (Chip-On-Flex) Using ACFs (Anisotropic Conductive Films) for CCM (Compact Camera Module) (ACF를 이용한 CCM (Compact Camera Module)용 COF(Chip-On-Flex) 실장 기술 및 신뢰성 연구)

  • Chung, Chang-Kyu;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.7-15
    • /
    • 2008
  • In this paper, the Chip-On-Flex (COF) assembly process using anisotropic conductive films (ACFs) was investigated and the reliability of COF assemblies using ACFs was evaluated. Thermo-mechanical properties of ACFs such as coefficient of thermal expansion (CTE), storage modulus (E'), and glass transition temperature $(T_g)$ were measured to investigate the effects of ACF material properties on the reliability of COF assemblies using ACFs. In addition, the bonding conditions for COF assemblies using ACFs such as time, temperature, and pressure were optimized. After the COF assemblies using ACFs were fabricated with optimized bonding conditions, reliability tests were then carried out. According to the reliability test results, COF assemblies using the ACF which had lower CTE and higher $T_g$ showed better thermal cycling reliability. Consequently, thermo-mechanical properties of ACFs, especially $T_g$, should be improved for high thermal cycling reliability of COF assemblies using ACFs for compact camera module (CCM) applications.

  • PDF

Improvement of COF Bending-induced Lead Broken Failure in LCD Module (LCD Module내 COF Bending에 따른 Lead Broken Failure의 개선)

  • Shim, Boum-Joo;Choi, Yeol;Yi, Jun-Sin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.3
    • /
    • pp.265-271
    • /
    • 2008
  • TCP(Tape Carrier Package), COG (Chip On Glass), COF(Chip On Film) are three methods for connecting LDI(LCD Driver IC) with LCD panels. Especially COF is growing its portion of market place because of low cost and fine pitch correspondence. But COF has a problem of the lead broken failure in LCD module process and the usage of customer. During PCB (Printed Circuit Board) bonding process, the mismatch of the coefficient of thermal expansion between PCB and D-IC makes stress-concentration in COF lead, and also D-IC bending process during module assembly process makes the level of stress in COF lead higher. As an affecting factors of lead-broken failure, the effects of SR(Solder Resister) coating on the COF lead, surface roughness and grain size of COF lead, PI(Polyimide) film thickness, lead width and the ACF(Anisotropic Conductive Film) overlap were studied, The optimization of these affecting manufacturing processes and materials were suggested and verified to prevent the lead-broken failure.

Development of Real-time Flatness Measurement System of COF Film using Pneumatic Pressure (공압을 이용한 COF 필름의 실시간 위치 평탄도 측정 시스템 개발)

  • Kim, Yong-Kwan;Kim, JaeHyun;Lee, InHwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2021
  • In this paper, an inspection system has been developed where pneumatic instruments are used to stretch the film using compressed air, thus the curl problem can be overcome. When the pneumatic system is applied, a line scan camera should be used instead of an area camera because the COF surface makes an arc by the air pressure. The distance between the COF and the inspection camera should be kept constant to get a clear image, thus the position of COF is to be monitored on real-time. An operating software has been also developed which is switching on/off the pneumatic system, determining the COF position using a camera vision, displaying the contour of the COF side view, sending self-diagnosis result and etc. The developed system has been examined using the actual roll of COF, which convince that the system can be an effective device to inspect the COF rolls in process.

Effects of Composted Organic Fertilizer and Urea Application to Soil on the Ammonia Emissions and Fruit Quality of 'Beni Balad' Grapevine in Rain Proof Cultivation ('Beni Balad' 포도 비가림 재배에서 부숙유기질비료 및 Urea 토양 시용에 의한 암모니아 배출량 및 과실 품질)

  • Moon, Young-Ji;Moon, Byung-Woo;Kim, Min-Wook
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.313-321
    • /
    • 2021
  • BACKGROUND: Ammonia is a causative substance for the fine particulate matters (PM2.5) and generates dust through atmospheric reactions. Agricultural sector accounts for 79.3% of ammonia emissions in Korea. Urea and composted organic fertilizer (COF) are used in the soil for the purpose of supplying nutrients in grapevine orchards. This study was conducted to investigate estimates of ammonia emission and examine fruit quality from the rain proof cultivation of the 'Beni Balad', applied by urea and COF to the soil. METHODS AND RESULTS: Urea, COF1, and COF2 were applied at the rates of 119, 135, and 271 kg ha-1 respectively. Ammonia emissionwas measured using a dynamic flow-through method. CONCLUSION(S): Ammonia emissions by urea and COF treatments to 'Beni Balad' soils under rain proof cultivation were calculated to be 2.63, 12.95, 2.05, and 3.97 kg NH3-N ha-1 day-1, respectively for the control, urea, COF1, and COF2. Urea soil application increased soluble solids, firmness, and anthocyanin content in fruits at harvest, and COF1 application increased the soluble solids and anthocyanin content. For all the treatments, acidity increased in the harvested fruits.

Development of Real-Time TCP/COF Inspection System using Differential Image (차영상을 이용한 실시간 TCP/COF 검사 시스템 개발)

  • Lee, Sang-Won;Choi, Hwan-Yong;Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.1
    • /
    • pp.87-93
    • /
    • 2012
  • In this paper, we proposed a faulty pattern detection algorithm of TCP(Tape Carrier Package)/COF(Chip On Film), and implemented a real-time system for inspecting TCP/COF. Since TCP/COF has very high resolution having several micro meters, the human operator should visually inspect all the parts through microscope. In this work, we implement an inspection system to detect the faulty pattern, so the operator can visually inspect only the designated parts by the inspection system through the monitor. The proposed defects detection algorithm for TCP/COF packages is implemented by the pattern matching method based on subtracting the reference image from test image. To evaluate performance of the proposal system. we made various experiments according to type of CCD camera and light source as well as illumination projection method. From experimental results, it is confirmed that the proposed system makes it possible to detect effectively the defective TCP/COF film.

Studies on Adsorption and Desorption of Ammonia Using Covalent Organic Framework COF-10 (Covalent Organic Framework (COF-10)를 이용한 암모니아 흡착 및 탈착에 관한 연구)

  • Yang, Heena;Kim, Iktae;Ko, Youngdon;Kim, Shindong;Kim, Whajung
    • Applied Chemistry for Engineering
    • /
    • v.27 no.3
    • /
    • pp.265-269
    • /
    • 2016
  • Ammonia gas as a hydrogen source has received great attention since the importance of hydrogen gas as a clean energy source increased. However, ammonia is toxic and corrosive to metal such that the absorbent that can store and transport ammonia became an important issue. As an effort to solve this, a large pored covalent organic framework, COF-10 was proposed as an adsorbent for storage and safe transportation of ammonia. During the ammonia adsorption process, boron in COF-10 structure can act as a Lewis acid site and bind with ammonia. In this study, COF was synthesized and its structure was identified by BET, XRD and FT-IR. The adsorption characteristics of COF were investigated by TPD and adsorption isotherm. The COF-10 showed an excellent adsorption capacity for ammonia (9.79 mmol/g) which could be utilized as an ammonia adsorbent.

Studies on the Development of Liquid Chromatographic Methods for Pesticide Residues (I)-Separation Optimization of Thiocarbamates (잔류농약의 액체 크로마토그래피 분석법 개발에 관한 연구 (I) Thiocarbamates 제초제의 분리 최적화)

  • Lee Dai Woon;Choi Yong Wook;Suh Joon Ha
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • The method for investigating the retention behavior and separation optimization was studied to develop a reversed-phase liquid chromatography of eleven thiocarbamates that are used as herbicides. As an isocratic elution system, the statistical simplex technique was applied to find the optimum separation conditions. The resolution was quantitatively evaluated by using COF and ORM method. For thiocarbamate herbicides in which the elution order varies dramatically with solvent composition, the ORM method gave better result than the COF method. For the solvent composition of mobile phase in the ORM method, the ratio of methanol : acetonitrile : tetrahydrofuran : water was 16 : 29 : 2 : 53. Also in this research, an adjusted COF $(\overline{COF})$ method was proposed to rectify the defect in the current COF method, and the compositional ratio of mobile phase containing methanol : acetonitrile : water was 29.5 : 21.5 : 49.0 result of which is similar to that obtained by the ORM method.

  • PDF

Covalent Organic Framework Based Composite Separation Membrane: A Review (공유 유기 골격체 기반 복합 분리막 : 고찰)

  • Jeong Hwan Shim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.149-157
    • /
    • 2023
  • Covalent organic frameworks (COFs) have shown promise in various applications, including molecular separation, dye separation, gas separation, filtration, and desalination. Integrating COFs into membranes enhances permeability, selectivity, and stability, improving separation processes. Combining COFs with single-walled carbon nanotubes (SWCNT) creates nanocomposite membranes with high permeability and stability, ideal for dye separation. Incorporating COFs into polyamide (PA) membranes improves permeability and selectivity through a synthetic interfacial strategy. Three-dimensional COF fillers in mixed-matrix membranes (MMMs) enhance CO2/CH4 separation, making them suitable for biogas upgrading. All-nanoporous composite (ANC) membranes, which combine COFs and metal-organic framework (MOF) membranes, overcome permeance-selectivity trade-offs, significantly improving gas permeance. Computational simulations using hypothetical COFs (hypoCOFs) demonstrate superior CO2 selectivity and working capacity relevant for CO2 separation and H2 purification. COFs integrated into thin-film composite (TFC) and polysulfonamide (PSA) membranes enhance rejection performance for organic contaminants, salt contaminants, and heavy metal ions, improving separation capabilities. TpPa-SO3H/PAN covalent organic framework membranes (COFMs) exhibited superior desalination performance compared to traditional polyamide membranes by utilizing charged groups to enable efficient desalination through electrostatic repulsion, suggesting their potential for ionic and molecular separations. These findings highlight COFs' potential in membrane technology for enhanced separation processes by improving permeability, selectivity, and stability. In this review, COF applied for the separation process is discussed.

Defects Detection of TCP, COF Using Image Processing (영상 처리 기법을 이용한 TCP, COF의 불량 검출)

  • Mun, Hui-Jeong;Jeon, Myeong-Geun;Park, Jin-Il
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.174-175
    • /
    • 2008
  • 본 논문에서는 반도체 패키징 기술의 일종인 TCP, COF의 제품 결함을 영상 처리를 이용하여 검출하는 알고리즘을 제시하고, 신뢰성을 확보 후 실제 검사 공정에 적용하는 방법론을 제시한다. 제안된 방법으로는 TCP, COF의 양품 패턴을 기준 영상으로 취득하고, 제품의 생산 과정에서 라인 스캔 카메라를 이용한 실시간 제품 영상을 취득한 후, 그레이 레벨 영상으로 변환하고, 노이즈를 제거하기 위한 다양한 필터를 적용한다. 그리고 기준 영상과 비교하기 위한 이진화와 라벨링을 통해 제품의 불량을 검출하여, 사용자에게 시각적으로 표현해 주게 된다. 마지막으로 TCP, COF의 다양한 불량 항목 중에서 10여 가지의 불량패턴을 대상으로 제안된 방법의 타당성을 검증하였다.

  • PDF

Application of Risk-Based Inspection with Financial Risk for a Petrochemical Process (석유화학공정에서 재정적 위험도에 의한 위험기반검사의 적용)

  • Kim, Tae-Ok;Lee, Joong-Hee;Choi, Sung-Kyu;Lee, Hern-Chang;Jo, Ji-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.53-60
    • /
    • 2009
  • For the case of the facilities using utilities such as cooling water and steam, risk of the facilities is zero because the consequence of failure (COF) through equipment damage area is zero. Therefore, to improve the estimation method of the risk by COF through equipment damage area in the risk-based inspection (RBI), this study developed the procedures of RBI, in which the risk was estimated by COF through financial loss. And, the RBI program (KS-RBI Ver 3.1) was developed to establish inspection interval based on the risk of the facilities estimated by COF through equipment damage area and financial loss, simultaneously, and the developed RBI program was applied to a petrochemical process. As a result, risks of the facilities estimated by COF through financial loss were similar to risks by COF through the equipment damage area. But, for the case of the facilities using utilities or expensive facilities, the estimation method of the risk by COF through financial loss was more accurate than through equipment damage area.

  • PDF