Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor (전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술)

  • Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

Establishment of National Standard System for 20.000 A Current Transformer (20,000 A 전류변성기 국가표준 시스템 구축)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jean-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.6-13
    • /
    • 2008
  • National standard system for calibrating current transformer(CT) up to primary current of 20,000A have been established. The system consists of 20,000 A AC high current source, CT comparator, standard CT, CT under test and CT burden. An AC high current is applied tn the primary windings of both the standard CT and the CT under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary currents of the two transformers. As a validity check for 20,000 A CT calibration system, the comparison with the two national standard institutes(NMIs) has been performed using same CTs. The comparison results of the CTs are consistent with those measured at two NMIs within 0.004 % for ratio error and 0.1 min for phase displacement in the primary current ranges of Ip = 10 - 20,000 A with a secondary current of Is = 5 A.

A Study on Usefulness Verification Technique of the Measurement System by the Difference Between Caculated and Experimental Values of Ratio Error/phase Annie Error in Current Transformer (전류변성기의 비오차와 위상각오차의 계산값과 실험값의 차에 의한 측정시스템 유용성 검증기술에 관한 연구)

  • 정재갑;권성원;이상화;박영태
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.213-217
    • /
    • 2004
  • A current transformer(CT) used for the estabilishment of high current national standard, has generally very small ratio error and phase angle error. Both the errors of CT depend critically on the external burden used. When both the ratio and phase angle errors at two different burdens including zero burden are known, those at any other burdens are calculated theoretically. The theoretical values are well consistent with the experimental results within the $82{\times}10$-6, implying the measurement system of CT in KRISS is well maintained.

On-Site Evaluation Technique of Current Transformer Comparator System (전류변성기 비교측정 장치의 현장 평가기술)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kwon, Sung-Won;Kang, Jeon-Hong;Kim, Myung-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

Effects of Dexamethasone on the Burden of Marine Birnavirus (MABV) in Olive Flounder, Paralichthys olivaceus (Dexamethasone 투여가 넙치(Paralichthys olivaceus)의 marine birnavirus (MABV) 감염강도에 미치는 영향)

  • Kwon, Se Ryun;Nam, Yoon Kwon
    • Korean Journal of Ichthyology
    • /
    • v.19 no.2
    • /
    • pp.88-92
    • /
    • 2007
  • The effect of dexamethasone injection on the burden of marine birnavirus (MABV) in asymptomatically infected olive flounder (Paralichthys olivaceus) fingerlings was investigated. In real time PCR analysis, the threshold cycle (Ct) value of the fish injected with dexamethasone was significantly lower than that of the fish in the PBS-injected and no-handling groups. The higher amplification of the MABV gene in the dexamethasone-injected group than the 2 control groups was confirmed also by semi-quantitative RT-PCR. The results indicate an increase of MABV burden in olive flounder fingerlings after a single injection with dexamethasone.

Discrimination Method of Internal and External Fault of Current Differential Relay using Instantaneous Value of Current in Case of Fault with One end CT Saturation (편단 CT 포화 고장 발생시 양단 전류 순시치를 이용한 전류차동계전기의 내·외부 고장위치 판별방안)

  • Lee, Myoung-Hee;Choi, Hae-Sul;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1801-1806
    • /
    • 2012
  • This paper presents a simple and practical method which enables to prevent malfunction of protection relay due to differential current caused by one end CT saturation in case of external fault. This method uses difference of magnitude(instantaneous value) between the both end current just before the occurrence of differential current without a separate method to CT staturation detection. One end CT saturation is simulated by current transformer model using type-96 component and the presented method is verified by using EMTP MODELS with respect to internal and external fault with one end CT staturation. The presented method distinguished rightly bewteen external and internal fault with one end CT saturation. This information can be used to prevent malfunction of current differential protection relay in case of external fault. And this method is not affected by sampling rate and has no calculation burden, so it will be applicable to differential current protection relay with ease.

Establishment of Evaluation System for 40,000 A Rogowski Coil (40,000 A 로고스키 코일 평가 시스템 구축)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Kang, Jeon-Hong;Lee, Sang-Hwa;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.202-206
    • /
    • 2009
  • Evaluation system for calibrating Rogowski coiI(RC) up to primary current of 40,000 A have been established. The system consists of 40,000 A AC high current source, current transformer(CT) comparator, standard CT, RC under test, voltage to current convertor(VCC), buffer and CT burden. An AC high current is applied to the primary windings of both the standard CT and the RC under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary current of the standard CT with output current of VCC. For testing of RC, we have evaluated two RCs under test of primary current ranges of 0 A ${\sim}$ 2,000 A and 0 A ${\sim}$ 40,000 A with the accuracy class of 1 %. The extended uncertainty is 0.02 % ${\sim}$ 0.23 % for ratio error and 0.29 min ${\sim}$ 1.93 min for phase displacement in the primary current ranges of 10 ${\sim}$ 40,000 A.

Importance of PET/CT Scan Use in Planning Radiation Therapy for Lymphoma

  • Milana, Mitric-Askovic;Marko, Erak;Miroslav, Latinovic;Tihomir, Dugandzija
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2051-2054
    • /
    • 2015
  • Background: Radiation therapy is a key part of the combined modality treatment for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), which can achieve locoregional control of disease. The 3D-conformal radiation oncology can be extended-field (EFRT), involved-field (IFRT) and involved node (INRT). New techniques have resulted in a smaller radiation field and lower dose for critical organs such as lung heart and breast. Materials and Methods: In our research, we made a virtual simulation for one patient who was treated in four different radiotherapeutic techniques: mantle field (MFRT), EFRT, IFRT and INRT. After delineatiion we compared dose-volume histograms for each technique. The fusion of CT for planning radiotherapy with the initial PET/CT was made using Softver Xio 4.6 in the Focal program. The dose for all four techniques was 36Gy. Results: Our results support the use of PET/CT in radiation therapy planning. With IFRT and INRT, the burden on the organs at risk is less than with MFRT and EFRT. On the other hand, the dose distribution in the target volume is much better with the latter. Conclusions: The aim of modern radiotherapy of HL and NHL is to reduce the intensity of treatment and therefore PET/CT should be used to reduce and not increase the amount of tissue receiving radiation.

Design of Computational Thinking Instruction Based on ARCS Model in Liberal Arts Education (교양교육에서 ARCS 모형 기반의 컴퓨팅 사고력 수업 설계)

  • Jun, Soo-jin;Shin, Chwa-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.90-93
    • /
    • 2019
  • Recently, as SW education has been emphasized in college, interest in Computing Thinking (CT) class at the liberal level has increased. In order to effectively educate students, various methods of teaching and learning are required to reduce the burden on CT education and motivation of students. The purpose of this study is to design teaching and learning using ARCS model to improve learners' learning motivation and learning achievement in CT course as liberal arts education. In this study, the learning elements of CT were selected based on previous research on the characteristics of education in the liberal arts education of the university and analysis of the CT content. In addition, Keller 's ARCS learning motive model was selected to match the instructional tactics according to the motivational factors of Attention, Relevance, Confidence, and Satisfaction. In order to effectively teach these CT contents, detailed strategies based on the ARCS model were designed and presented weekly.

  • PDF

The Study on a Various Parameter for the CT Test and the Patients-Anxiety of Factor Related (CT검사 시 다양한 매개변수와 환자의 불안 요인에 관한 연구)

  • Baek, Cheol-Oh;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.149-156
    • /
    • 2011
  • This study is to identify perceptions and response degrees of anxiety for each factor, targeting patients for CT test and analyze the relations between factors. It is to provide scientific fundamental data to reduce anxiety by improving awareness of patients about CT test by analyzing relations between variables. The subjects of this study were surveyed in self-writing type, targeting 263 patients for CT test in the department of radiology at three University hospitals from July to September, 2010. This survey was executed once by a structured self-administered survey type. The targeting patients for CT test of anxiety will investigate for affect. Anxiety by each CT test variables depending on CT test-related features showed independent variable is Expense Responsibility, Economic burden, Sufficient explain, Explain agent, Endoscope, Biopsy, Pre treatment, Previous experience, CT side effect experience, Side effect of contrast medium and dependent variable is physical, Hospital staff, Hospital environment, Socioeconomic These used statistics program SPSS (ver. 13.0). Summarizing the above results of this study, awareness of anxiety and response to it in each variable under CT test appeared significant differences in economic burdens, state anxiety, pre-treatment anxiety, exposure anxiety to radiation, and anxiety of side effect. Therefore, pre-treatment before test and pre-training programs on chemical poison of contrast medium and side effect seem to be able to release patients' anxiety level for CT test. Ways to meditate these anxiety variables and reduce degree of anxiety are needed to be researched more and updated. In addition, impact of patients' economic burdens on CT test anxiety is required to be recognized and solved in society level.