• Title/Summary/Keyword: Capillary electrophoresis

Search Result 173, Processing Time 0.027 seconds

Development of analytical method capable of identifying the chemically or biologically oriented variants of human growth hormone by capillary electrophoresis

  • Shin, Hyoung-Goo;Hong, Sung-Tae;Son, Jae-Woon;Youn, Yu-Seok;Han, Hye-Seon;Lee, Kang-Choon
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.230.3-231
    • /
    • 2003
  • The therapeutic use of protein pharmaceuticals produced by recombinant DNA technology is increasing in recent decades. In order to investigate the quality of recombinant proteins, it is important to identify and assign the impurities produced in the process of recombination or in storage conditions. Capillary Electrophoresis is emerging technology exhibiting high sensitivity, selectivity and speed and may be most powerful tools for this application. In this study, human growth hormone (hGH) has been analyzed by various mode of capillary electrophoresis such as capillary zone electrophoresis (CZE), capillary gel electrophoresis (CGE), and capillary isoelectric focusing (cIEF) to indicate the chemically or biologically oriented variants and the degraded fragments. (omitted)

  • PDF

Analysis of Health-related Microbes by Capillary Electrophoresis

  • Moon, Byoung-Geoun;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1203-1206
    • /
    • 2003
  • Analysis of health-related microbes called probiotics was performed by capillary electrophoresis. A rapid and easy characterization for two important probiotics, Saccharomyces cerevisiae and Enterococcus feacalis, was obtained in the running buffer containing poly(ethylene oxide). Quantitation of probiotic (Saccharomyces cerevisiae) shows a good linearity between the peak area versus the concentration of microbe. From the comparison of electropherograms of antidiarrhea, it was found that capillary electrophoresis could be employed for the quality control and quality assurance for the production of a medicine containing the probiotics.

Applications of Capillary Electrophoresis and Microchip Capillary Electrophoresis for Detection of Genetically Modified Organisms

  • Guo, Longhua;Qiu, Bin;Xiao, Xueyang;Chen, Guonan
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.823-832
    • /
    • 2009
  • In recent years, special concerns have been raised about the safety assessment of foods and food ingredients derived from genetically modified organisms (GMOs). A growing number of countries establish regulations and laws for GMOs in order to allow consumers an informed choice. In this case, a lot of methods have been developed for the detection of GMOs. However, the reproducibility among methods and laboratories is still a problem. Consequently, it is still in great demand for more effective methods. In comparison with the gel electrophoresis, the capillary electrophoresis (CE) technology has some unique advantages, such as high resolution efficiency and less time consumption. Therefore, some CE-based methods have been developed for the detection of GMOs in recent years. All kinds of CE detection methods, such as ultraviolet (UV), laser induced fluorescence (LIF), and chemiluminescence (CL) detection, have been used for GMOs detection. Microchip capillary electrophoresis (MCE) methods have also been used for GMOs detection and they have shown some unique advantages.

Affinity chromatography and capillary electrophoresis for analysis of the yeast ribosomal proteins

  • Goyder, Miriam S.;Willison, Keith R.;Klug, David R.;DeMello, Andrew J.;Ces, Oscar
    • BMB Reports
    • /
    • v.45 no.4
    • /
    • pp.233-238
    • /
    • 2012
  • We present a top down separation platform for yeast ribosomal proteins using affinity chromatography and capillary electrophoresis which is designed to allow deposition of proteins onto a substrate. FLAG tagged ribosomes were affinity purified, and rRNA acid precipitation was performed on the ribosomes followed by capillary electrophoresis to separate the ribosomal proteins. Over 26 peaks were detected with excellent reproducibility (<0.5% RSD migration time). This is the first reported separation of eukaryotic ribosomal proteins using capillary electrophoresis. The two stages in this workflow, affinity chromatography and capillary electrophoresis, share the advantages that they are fast, flexible and have small sample requirements in comparison to more commonly used techniques. This method is a remarkably quick route from cell to separation that has the potential to be coupled to high throughput readout platforms for studies of the ribosomal proteome.

Application of Capillary Electrophoresis for Quality Control Analysis of Complex Medicine (모세관 전기영동 분석법의 복합약물제제의 품질관리 분석에 응용을 위한 연구)

  • Heo, Yoo-Jeong;Lee, Kong-Joo
    • YAKHAK HOEJI
    • /
    • v.41 no.5
    • /
    • pp.539-546
    • /
    • 1997
  • Capillary electrophoresis (CE) is perceived as an attractive tool for the analysis of pharmaceuticals and biological materials because of their high separation efficiency, easy separation and low running cost. New concept of micellar electrokinetic capillary chromatography (MECC) expanded the application of CE to the separation of neutral molecules. Validation of CE as an analytical technique for quality control of pharmaceuticals should be confirmed by quantitative analysis and the peak confirmation. In this study, the quantitative analyses of various types of neutral, acidic and basic components (acetaminophen, caffeine, ascorbic acid, riboflavin, thiamine, chlorpheniramine, phenylpropanolamine, dl-methylephedrine and dextromethorphan) in complex cold medicines have been accomplished using CE. Combined methods of MECC using SDS and capillary zone electrophoresis lowering the pH of running buffer were adopted to determine the ingredients in capsule type or liquid formula complex medicines without particular sample pretreatment. The results indicate that CE is a promising technique for quality control analysis of pharmaceuticals as a validation method.

  • PDF

Analysis of Double-Stranded DNA Fragments by Capillary Electrophoresis Using Entangle Polymer Solutions in Uncoated Fused Silica Capillary Columns

  • Lee, Jong-Jin;Lee, Kong-Joo
    • BMB Reports
    • /
    • v.31 no.4
    • /
    • pp.384-390
    • /
    • 1998
  • DNA fragments (51-587 bp) were separated by capillary electrophoresis using entangled polymer, hydroxyethylcellulose, in uncoated fused silica capillary columns. The factors affecting the separation of DNA fragments with hydroxyethylcellulose media were evaluated, i.e., the concentration of buffer and entangled polymer, effects of additives (methanol, ethidium bromide, EDTA), temperature, and injection methods. Maximum performance was obtained by adding 5% methanol in 0.5% hydroxyethylcellulose solution at $30^{\circ}C$. Addition of methanol in polymer media increased the resolution of small size DNA fragments (< 100 bp). On the other hand, addition of ethidium bromide and EDTA, which are commonly used in conventional DNA separation, reduced the resolution of DNA fragments in the polymer solution. It turns out that the separation behavior of DNA in entangled polymer is more sensitive to the running condition compared to that in polyacrylamide gel-filled capillary, but the reproducibility of DNA separation in entangled polymer is reliable.

  • PDF

Characterization of Two Ricin Isoforms by Sodium Dodecyl Sulfate-Capillary Gel Electrophoresis and Capillary Isoelectric Focusing

  • Na, Dong-Hee;Park, Eun-Ji;Kim, Myung-Sun;Cho, Cheong-Kwan;Woo, Byung-Ho;Lee, Hye-Suk;Lee, Kang-Choon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4253-4257
    • /
    • 2011
  • Sodium dodecyl sulfate-capillary gel electrophoresis (SDS-CGE) and capillary isoelectric focusing (CIEF) were employed to characterize and compare ricin E purified from the small grain seeds of Ricinus communis with ricin D isoform. During the purification of ricin E using ion-exchange and size-exclusion chromatography, SDS-CGE was found to be useful for monitoring the efficiencies of purification steps. SDS-CGE showed that the molecular size of ricin E was not significantly different from that of ricin D, which was confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. CIEF was useful for discriminating ricin E from ricin D based on their isoelectric points (pI). The pI values of ricin E and D were 8.6-8.8 and 7.0-7.4, respectively. This study demonstrates the usefulness of SDS-CGE and CIEF for the characterization of ricin toxins.

Separation of racemic enantiomer carvedilol and its metabolites using capillary electrophoresis (Capillary Electrophoresis에 의한 carvedilol 및 그 대사체의 거울상이성질체 분리)

  • Jo, Cheon-Ho;Koo, So-Hyun;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.275-279
    • /
    • 2006
  • A capillary electrophoresis method for the separation of carvedilol and its metabolites enantiomers using cyclodextrins as the chiral selectors was developed. The effect of several types of cyclodextrins, concentration and capillary temperature for enantiomer resolution were investigated. Best results were obtained by 15 mM carboxymethyl-${\beta}$-cyclodextrin in the run buffer. Also the effect of capillary temperature on efficiency was assessed. The optimized method was applied for separation of chiral carvedilol and its three metabolites.

Fabrication of plastic CE (capillary electrophoresis) microchip by hot embossing process (핫 엠보싱 공정을 이용한 플라스틱 CE(capillary electrophoresis) 마이크로 칩의 제작)

  • Cha Nam-Goo;Park Chang-Hwa;Lim Hyun-Woo;Park Jin-Goo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1140-1144
    • /
    • 2005
  • A plastic-based CE (capillary electrophoresis) microchip was fabricated by hot embossing process. A Si mold was made by wet etching process and a PMMA wafer was cut off from 1mm thick PMMA sheet. A micro-channel structure on PMMA substrate was produced by hot embossing process using the Si mold and the PMMA wafer. A vacuum assisted thermal bonding procedure was employed to seal an imprinted PMMA wafer and a blank PMMA wafer. The results of microscopic cross sectional images showed dimensions of channels were well preserved during thermal bonding process. In our procedure, the deformation amount of bonding process was below 1%. The entire fabrication process may be very useful for plastic based microchip systems.

  • PDF