• 제목/요약/키워드: Cast-in anchor

검색결과 42건 처리시간 0.026초

수치해석에 의한 직매형 앵커기초의 인장 설계기준 평가 (Tensile Design Criteria Evaluation of Cast-In-Place Anchor by Numerical Analysis)

  • 장정범;서용표;이종림
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2004
  • Numerical analysis is carried out to identify the appropriateness of the design codes that is available for the tensile design of fastening system at Nuclear Power Plant (NPP) in this study. This study is intended for the cast-in-place anchor that is widely used for the fastening of equipment in Korean NPPs. The microplane model and the elastic-perfectly plastic model are employed for the quasi-brittle material like concrete and for the ductile material like anchor bolt as constitutive model for numerical analysis and smeared crack model is employed for the crack and damage phenomena. The developed numerical model is verified on a basis of the various test data of cast-in-place anchor. The appropriateness of both ACI 349 Code and CCD approach of CEB-FIP Code is evaluated for the tensile design of cast-in-place anchor and it is proved that both design codes give a conservative results compared with real tensile capacity of cast-in-place anchor.

  • PDF

수치해석에 의한 직매형 앵커기초의 인장설계기준 평가 (An Evaluation of Tensile Design Criteria of Cast-In-Place Anchor by Numerical Analysis)

  • 서용표;장정범
    • 한국전산구조공학회논문집
    • /
    • 제18권3호
    • /
    • pp.303-309
    • /
    • 2005
  • 본 연구에서는 국내 원전에서 기기 정착을 위하여 가장 널리 적용되는 직매형 앵커기초를 대상으로 앵커기초의 인장 설계기준에 대한 적정성을 검토하기 위하여 수치해석이 수행되었다. 본 연구에서 수치해석모형에 적용된 파괴기준으로서 콘크리트와 같은 유사 취성재료에는 Microplane모형이, 앵커볼트와 같은 연성재료에는 탄성-완전 소성모형이 적용되었다. 그리고, 균열 발생현상을 모사하기 위하여 분산균열모형을 채택하였다. 개발된 수치해석모형은 다양한 경우의 실증시험결과를 근거로 신뢰성이 검증되었으며, 검증된 수치해석모형과 앵커볼트의 유효매입깊이를 변수로 한 다양한 경우에 대한 수치해석을 통하여 직매형 앵커기초의 인장설계기준으로서 적용이 가능한 ACI 349 Code와 CEB-FIP Code가 평가되었고, 그 보수성이 확인되었다.

풍화암에 근입된 영구 앵커의 극한인발력 (Ultimate Uplift Capacity of Permanent Anchor Embedded in Weathered Rock)

  • 유남재;박병수;정길수;김진황
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.195-203
    • /
    • 2001
  • The purpose of this study is to estimate ultimate uplift capacity of permanent anchor which was cast into weathered rock. The ultimate uplift capacity was estimated from the load-displacement curve of four different anchors which have different bond length. The creep test was performed for 15minutes under the maximum load of each step in order to understand the load-transfer property of permanent anchor and to decide which anchor to choose. The destruction range of soil due to the changes in load was estimated by installing dial gauge on the ground which was cast into the weathered rock. Ultimately, the study on the behavior of the anchor case into the weathered rock was performed by comparing and analyzing the estimated result of the UUC obtained by the full scale pull out test in the field with the exsting theoretical and practical results of soil and rock anchor.

  • PDF

새로운 형태의 선설치 인서트 앵커에 대한 단조 인장 및 전단강도 평가 (Tensile and Shear Strengths of New Type of Cast-in-Place Concrete Insert Anchors Under Monotonic Loading)

  • 전주성;김지훈;오창수;이창환
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.49-56
    • /
    • 2021
  • The damage to non-structural elements in buildings has been increasing due to earthquakes. In Korea, post-installed anchors produced overseas have been mainly used for seismic anchorage of non-structural components to structures. Recently, a new cast-in-place concrete insert anchor installed in concrete without drilling has been developed in Korea. In this paper, an experimental study was conducted to evaluate the tensile and shear strengths of the newly developed anchor under monotonic load. The failure modes of the tension specimens were divided into concrete breakout failure and steel failure, and all shear specimens showed steel failure. In both tension and shear, the maximum loads of specimens were greater than the nominal strengths predicted by the concrete design code (KDS 14 20 54). As a result, it is expected that the current code can also be used to calculate the strength of the developed cast-in anchor.

Dynamic shear strength of unreinforced and Hairpin-reinforced cast-in-place anchors using shaking table tests

  • Kim, Dong Hyun;Park, Yong Myung;Kang, Choong Hyun;Lee, Jong Han
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.39-58
    • /
    • 2016
  • Since the publication of ACI 318-02, the concrete capacity design (CCD) method has been used to determine the resistance of unreinforced concrete anchors. The regulation of steel-reinforced anchors was proposed in ACI 318-08. Until ACI 318-08, the shear resistance of concrete breakout for an unreinforced anchor during an earthquake was reduced to 75% of the static shear strength, but this reduction has been eliminated since ACI 318-11. In addition, the resistance of a hairpin-reinforced anchor was calculated using only the strength of the steel, and a regulation on the dynamic strength was not given for reinforced anchors. In this study, shaking table tests were performed to evaluate the dynamic shear strength of unreinforced and hairpin-reinforced cast-in-place (CIP) anchors during earthquakes. The anchors used in this study were 30 mm in diameter, with edge distances of 150 mm and embedment depths of 240 mm. The diameter of the hairpin steel was 10 mm. Shaking table tests were carried out on two specimens using the artificial earthquake, based on the United States Nuclear Regulatory Commission (US NRC)'s Regulatory Guide 1.60, and the Northridge earthquake. The experimental results were compared to the current ACI 318 and ETAG 001 design codes.

프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가 (Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch)

  • 안진희;임홍재;방진수;전석현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.94-102
    • /
    • 2020
  • 프리캐스트 콘크리트의 장점과 및 석조 아치의 거동을 접목한 콘크리트 패널 분절 아치 시스템은 가설재가 불필요한 시공성을 확보할 수 있는 경제적 시공법이다. 분절된 프리캐스트 콘크리트 패널의 연속 배치로 구성된 아치는 인양 및 시공을 위한 V형-스트립 연결부의 선설치 앵커 설치가 필수적이다. 그러나 좁은 폭과 얇은 두께의 콘크리트 패널은 선설치 앵커의 충분한 묻힘 깊이 확보를 보장할 수 없고 앵커 인발 거동 시 패널의 휨변형을 동반하는 등 앵커 저항성능 확보를 위한 콘크리트 패널의 기하학적 영향이 고려되어야 한다. 따라서 본 연구에서는 프리캐스트 패널과 강재 아웃리거로 구성된 아치구조의 제작시 설치되는 선설치 앵커의 인발 강도 평가를 위한 실험 연구를 수행하였다. 이를 위해 실제 아치 시스템과 동일한 크기의 프리캐스트 콘크리트 패널을 제작하였으며, 선설 앵커의 직경, 앵커 묻힘 깊이, 와이어 매쉬 사용 등의 영향에 따라 총 24개 실험체의 선설치 앵커 인발 강도를 측정하였다. 또한 측정 변수에 따른 설계기준강도 확보 및 파괴 모드 평가를 통해 프리캐스트 콘크리트 패널 분절 아치 구조에 적용 가능한 선설치 앵커의 형태를 결정하였다.

기기기초 시스템의 보강방안에 대한 연구 (Study on Reinforcing Method of Equipment Foundation System)

  • 송영철;최홍식;조명석;우상균;이시우;이성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.367-370
    • /
    • 2003
  • This study was carried out to suggest the effective reinforcing method which can evaluate the tensile capacity of cast-in-place anchor with cracks. Currently, cast-in-place anchor is used widely for the fastening of equipment in Korean NPPs. 26 test specimens with a single anchor under 4 cracked conditions are prepared using plain concrete. The distance between crack and anchor and reinforcing materials were selected as the main test variable. The tensile force was applied using a actuator with a capacity of 100 tonf using a displacement control method of 0.5 mm/min velocity. Test results from this result show the combination of carbon plate and epoxy will be more available for repair and reinforcement of equipment foundation system in NPPs. Further experimental work is indeed involving the epoxy injection effect and adjustment of reinforcing location of carbon sheet.

  • PDF

전단력을 받는 선설치 앵커볼트의 콘크리트 파열파괴강도 평가 연구 (A Study on the Concrete Breakout Capacity of CIP Anchor Bolts under Shear Loading)

  • 박용명;전명희;최명국;김철환;김인기
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.207-215
    • /
    • 2012
  • 전단하중을 받는 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2,000년 이후부터 CCD(Concrete Capacity Design) 방법이 새로운 설계법으로 도입되었다. 그러나, 본 방법은 주로 소형 앵커볼트에 대한 실험 결과에 근거한 관계로 앵커볼트의 직경이 50mm 이하인 경우에 한해 적용이 허용되고 있다. 따라서 큰 연단거리를 갖는 중대형 앵커볼트에 대한 합리적인 콘크리트 파열파괴강도식의 도출이 필요한 실정이다. 본 연구에서는 M56 선설치 단일 앵커볼트로 연단거리 350mm에 대해 콘크리트 파열파괴강도 평가를 위해 4개의 시험체에 대해 실험을 수행하였다. 그리고, 본 실험 결과와 타 연구의 실험 결과를 종합하여 연단거리 750mm까지의 큰 연단거리에 대해 새로운 전단파괴강도식을 제안하였다.

인장하중을 받는 중대형급 선설치 앵커볼트의 콘크리트파괴강도 평가를 위한 연구 (A Study on the Concrete Breakout Capacity Evaluation of Medium-to-Large size CIP Anchor Bolts under Tension Loading)

  • 박용명;전명희;이건준;김철환
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.493-501
    • /
    • 2011
  • 콘크리트용 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2,000년 이후부터 CCD(Concrete Capacity Design) 방법이 새로운 설계법으로 도입되었다. 그러나, 본 방법은 중소형 앵커볼트에 대한 실험 결과에 근거한 관계로 앵커볼트의 직경이 50mm 이하이고 매입깊이가 635mm 이하인 경우에만 허용되고 있다. 따라서 M50 이상의 중대형 앵커볼트에 대한 합리적인 인장파괴강도식의 도출이 필요한 실정이다. 본 연구에서는 매입깊이 400~450mm의 M56 선설치 단일 앵커볼트의 콘크리트 인장파괴강도 평가를 위해 5개의 시험체에 대해 실험을 수행하였다. 그리고, 본 실험 결과와 최근의 타 실험 결과를 종합하여 매입깊이가 280~1,200mm인 중대형급 앵커볼트에 대해 현 설계기준의 인장파괴강도식의 적용성 여부를 평가하였다.