• Title/Summary/Keyword: Cathode pressure

Search Result 229, Processing Time 0.04 seconds

Investigation of Factors Influencing Methanol Crossover in Direct Methanol Fuel Cell (직접메탄올연료전지에서 메탄올 크로스오버에 미치는 인자 연구)

  • Hyun, Min-Soo;Kim, Sang-Kyung;Lim, Seong-Yop;Lee, Byung-Rock;Peck, Dong-Hyun;Jung, Doo-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 2008
  • The amount of methanol crossover was measured with changing the operating condition by using a liquid methanol concentration sensor. Appropriate operating condition was discussed in terms of methanol crossover. Mechanism of methanol crossover was classified into three items which are diffusion, convection and electro-osmosis. Contribution of each mechanism to methanol crossover and the effect of operating condition were analyzed with varying methanol concentration, pressure difference between anode and cathode, current, temperature, and stoichiometry of anode fuel. Among the three mechanisms diffusion affected mostly and electro-osmosis effect was observed only under high methanol concentration.

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

Measurement of EUV Emission and its Plasma Parameters Generated from the Coaxial Plasma Focus of Mather and Hypocycloidal Pinched Electrodes

  • Lee, Sung-Hee;Lee, Kyung-Ae;Hong, Young-June;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.332-332
    • /
    • 2011
  • The extreme ultraviolet (EUV) radiation, whose wavelength is from 120 nm down to 10 nm, and the energy from 10 eV up to 124 eV, is widely utilized such as in photoelectron spectroscopy, solar imaging, especially in lithography and soft x-ray microscopy. In this study, we have investigated the plasma diagnostics as well as the debris characteristics between the two types of dense plasma focusing devices with coaxial electrodes of Mather and hypocycloidal pinch (HCP), respectively. The EUV emission intensity, electron temperature and plasma density have been investigated in these cylindrical focused plasma along with the debris characteristics. An input voltage of 5 kV has been applied to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas at pressure ranged from 1 mTorr and 180 mTorr. The inner surface of the cathode was covered by polyacetal insulator. The central anode electrode has been made of tin. The wavelength of the EUV emission has been measured to be in the range of 6~16 nm by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission has also been measured by the spectrometer with the wavelength range of 200~1,100 nm. The electron temperature and plasma density have been measured by the Boltzmann plot and Stark broadening methods, respectively, under the assumption of local thermodynamic equilibrium (LTE).

  • PDF

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

Development of CCFL with Nb/Ni Gad Electrode for high efficiency (Nb/Ni Clad 전극을 이용한 고효율 CCFL 개발)

  • Park, Ki-Duck;Yang, Seong-Su;Park, Doo-Sung;Kim, Seo-Yoon;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.441-443
    • /
    • 2005
  • According as CCFL(Cold Cathode Fluorescent lamp) of light source in Backlight unit for Note PC (Personal computer) is presently needed to low power consumption and long life time, the development focus of CCFL is going on the discharge gas, phosphor and electrode material. First of all, discharge voltage characteristic of CCFL is closely connected with electrode material For low discharge voltage, the characteristic of electrode material is needed to low work function, low sputtering ratio and superior manufacturing property. We developed new CCFL with Nb/Ni Clad electrode superior to conventional CCFL. Because Nb/Ni Clad electrode with Ni material and Nb material, the electrical characteristic is superior to other electrode materials. The electrode of Nb/Ni Clad is composed that Ni of outside material has superior manufacturing property and Nb of inside material has low work function. Nb/Ni Clad of new electrode material is made by process of Rolling mill at high pressure and heat treatment. We compared electrical characteristic of Nb/Ni clad electrode with conventional Mo electrode by measurement. Mo electrode and Nb/Ni Clad electrode of cup type with diameter 1.1 mm and length 3.0mm are used to this experiment. Material content of Mo electrode is Mo 100%. But, Nb/Ni Clad electrode is composed by content of Nb 40% and Ni 60%. The result of comparison measurement between new CCFL with Nb/Ni Clad electrode and conventional CCFL was appeared that CCFL with Nb/Ni Clad electrode had superior characteristic than conventional CCFL. As a result of experiment, we completed Note PC with low power consumption and long life time by application of new CCFL with Nb/Ni Clad electrode.

  • PDF

Measurement of electron temperature and density using Stark broadening of the coaxial focused plasma for extreme ultraviolet (EUV) lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.475-475
    • /
    • 2010
  • We have generated Ar plasma in dense plasma focus device with coaxial electrodes for extreme ultraviolet (EUV) lithography and investigated an emitted visible light for electro-optical plasma diagnostics. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas of pressure 8 mTorr. The inner surface of the cylindrical cathode has been attatched by an acetal insulator. Also, the anode made of tin metal. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature and density of the coaxial plasma focus could be obtained by Stark broadening of optical emission spectroscopy (OES). The Lorentzian profile for emission lines of Ar I of 426.629 nm and Ar II of 487.99 nm were measured with a visible monochromator. And the electron density has been estimated by FWHM (Full Width Half Maximum) of its profile. To find the exact value of FWHM, we observed the instrument line broadening of the monochromator with a Hg-Ar reference lamp. The electron temperature has been calculated using the two relative electron density ratios of the Stark profiles. In case of electron density, it has been observed by the Stark broadening method. This experiment result shows the temporal behavior of the electron temperature and density characteristics for the focused plasma. The EUV emission signal whose wavelength is about 6 ~ 16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD). The result compared the electron temperature and density with the temporal EUV signal. The electron density and temperature were observed to be $10^{16}\;cm^{-3}$ and 20 ~ 30 eV, respectively.

  • PDF

A Facile Process for Surface Modification with Lithium Ion Conducting Material of Li2TiF6 for LiMn2O4 in Lithium Ion Batteries

  • Kim, Min-Kun;Kim, Jin;Yu, Seung-Ho;Mun, Junyoung;Sung, Yung-Eun
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.223-230
    • /
    • 2019
  • A facile method for surface coating with $Li_2TiF_6$ which has a high lithium-ion conductivity, on $LiMn_2O_4$ spinel cathode material for high performance lithium ion batteries. The surface coating is performed by using a co-precipitation method with $Li_2CO_3$ powder and $H_2TiF_6$ solution under room temperature and atmospheric pressure without special equipment. Total coating amount of $Li_2TiF_6$ is carefully controlled from 0 to 10 wt.% based on the active material of $LiMn_2O_4$. They are evaluated by a systematic combination of analyses comprising with XRD, SEM, TEM and ICP. It is found that the surface modification of $Li_2TiF_6$ is very beneficial to high cycle life and excellent rate capability by reducing surface failure and supporting lithium ions transportation on the surface. The best coating condition is found to have a high cycle life of $103mAh\;g^{-1}$ at the 100th cycle and a rate capability of $102.9mAh\;g^{-1}$ under 20 C. The detail electrochemical behaviors are investigated by AC impedance and galvanostatic charge and discharge test.

Electrochemical Technologies : Water Treatment (전기화학공학 기술 : 수처리 공정)

  • Lee, Jaeyoung;Lee, Jae Kwang;Uhm, Sunghyun;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.235-242
    • /
    • 2011
  • This perspective describes recent advances made in the development of various electrochemical technologies to treat waste water containing organic pollutants, reducible/oxidizable and non-reducible/non-oxidizable anions and cations using redox reactions on the solid surface as well as at the interface between solid electrode and liquid electrolyte. Some of representative multiplexing and hybrid electrochemical treatment technologies are discussed, which have great advantages of high efficiency, stability and cost-effective instrumentation without the need of considering non-specific conditions such as high-temperature and high-pressure; however, choices and usages of electrode materials are absolutely critical issues.

Integrated Effect of Non-Invasive Neuromodulation on Bladder Capacity in Traumatic Spinal Cord Injury Patient: Single Case Report

  • Priyanka Dangi;Narkeesh Arumugam;Dinesh Suman
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.86-94
    • /
    • 2024
  • Objective: To evaluate the changes in bladder capacity and storage through non-invasive neuromodulation by application of repetitive Trans magnetic stimulation (rTMS) and genital nerve stimulation (GNS) in traumatic spinal cord survivors. Design: A Single Case Study. Method: The Patient was registered in trail with the clinical trial registry of India (CTRI/2022/05/042431). The Patient was interposed with rTMS on lumbar area, from T11-L4 vertebrae with 1 Hz and the intensity was 20% below that elicited local paraspinal muscular contraction for 13 minutes. GNS was placed over dorsum of the penis with the cathode at the base and anode 2 cm distally at 20 Hz, 200 microseconds, Continuous and biphasic current was delivered and amplitude of stimulation necessary to elicit the genito-anal reflex. For assessment, Neurological examination was done for peri-anal sensation (PAS), voluntary anal contraction (VAC) and bulbocavernous reflex (BCR), deep anal pressure (DAP), and American Spinal Injury Association Impairment Scale (ASIA scale). Outcome assessment was done using Urodynamics, Spinal Cord Independence Measure Scale Version-III (SCIM-III), American Spinal Injury Association Impairment Score (ASIA Score), Beck's Depression Inventory Scale (BDI). The baseline evaluation was taken on Day 0 and on Day 30. Results: The pre-and post-data were collected through ASIA score, SCIM-III, BDI and Urodynamics test which showed significant improvement in bladder capacity and storage outcomes in the urodynamics study across the span of 4 weeks. Conclusion: rTMS along with GNS showed improvement in bladder capacity & storage, on sensory-motor score, in functional independence of individual after SCI.

Fabrication and Electrochemical Characterization of All Solid-State Thin Film Micro-Battery by in-situ Sputtering (In-situ 스퍼터링을 이용한 잔고상 박막 전지의 제작 및 전기화학적 특성 평가)

  • Jeon Eun Jeong;Yoon Young Soo;Nam Sang Cheol;Cho Won Il;Shin Young Wha
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.115-120
    • /
    • 2000
  • All solid-state thin film micro-batteries consisting of lithium metal anode, an amorphous LiPON electrolyte and cathode of vanadium oxide have been fabricated and characterized, which were fabricated with cell structure of $Li/LiPON/V_2O_5Pt$. The effect of various oxygen partial pressure on the electrochemical properties of vanadium oxide thin films formed by d.c. reactive sputtering deposition were investigated. The vanadium oxide thin film with deposition condition of $20\%\;O_2/Ar$ ratio showed good cycling behavior. In in-siか process, the LiPON electrolyte was deposited on the $V_2O_5$ films without breaking vacuum by r.f. magnetron sputtering at room temperature. After deposition of the amorphous LiPON, the Li metal films were grown by a thermal evaporator in a dry room. The charge-discharge cycle measurements as a function of current density and voltage variation revealed that the $Li/LiPON/V_2O_5$ thin film had excellent rechargeable properly when current density was $7{\mu}A/cm^2$. and cut-off voltage was between 3.6 and 2.7V In practical experiment, a stopwatch ran on this $Li/LiPON/V_2O_5$ thin film micro-battery. This result means that thin film micro-battery fabricated by in-siか process is a promising for power source for electronic devices.