• Title/Summary/Keyword: Cell saver

Search Result 10, Processing Time 0.019 seconds

Effects of Autotransfusion Using Cell Saver in Cardiovascular Surgery (심혈관수술에서 cell saver를 이용한 자가수혈)

  • 구자홍
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 1993
  • The efficacy of the autotransfusion system is a reducing the need of intraoperative and postoperative transfusion in cardiovascular surgery. Between January 1990 and December 1991, we experienced 23 cases of autotransfusion using Haemonetic Cell Saver in cardiovascular surgery [Experimental group]. Another 13 cases which were taken similiar operations without Cell Saver during same period [Control group]. The amounts of blood transfused are 4.23 1.84 units in Control group, 2.82 1.84 units in Experimental group. Postoperatively, both groups showed decreased platelet counts, mild prolongation of prothrombin and partial thromboplastin time compred to preoperative value [P<0.001], but there were no significant differences between two group [P=NS]. Plasma hemoglobin was markedly increased in Experimental group compared with Control group [p<0.05]. In Experimental group, amount of average processed blood by Cell Saver was 700ml of which composition was hemoglobin 17mg/dl, hematocrit 50.0%, RBC 5,590,000/ml, WBC 7500/ml, and platelet 40,000/ml. The culture of the processed blood revealed no growth of the organisms. Conclusively, Cell Saver autotransfusion system is a simple, safe, and cost effective method especially in the cases associated with massive bleeding. However, it requires familiarity with system, gentle manipulation of suction tip, and careful selection of candidates to obtain maximal benefits .

  • PDF

Effects of Autotransfusion using Cell Saver in Open Heart Surgery (개심술시 Cell Saver를 이용한 자가수혈의 효과)

  • 윤경찬;최세영;유영선;이광숙;박창권
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.28-31
    • /
    • 1998
  • Homologous blood transfusion entails substantial risks, including allergic reactions, transmission diseases such as hepatitis, acquired immunodeficiency syndrome. Autotransfusion system is a common method of reducing the need for homologous blood transfusion during cardiac operation. Between July 1993 and July 1995, a series of 40 patients undergoing open heart surgery was selected to an autotransfusion group(n=20) or a control group(n=20). The cell saver system(AT1000, Electromedics, Englewood, CO, USA) was employed for autotransfusion. With this system, shed blood in operative field during cardiopulmonary bypass(CPB) and remained blood in cardiotomy reservior after CPB was aspirated by means of a locally heparinized collecting system. After centrifuge salvaged blood, the resulting red cell concentrate reinfused subsequently. The amounts of blood loss were 766.5$\pm$121.3 ml in cell saver group, 770.1$\pm$113.6 ml in control group, and there were no significant differences between two groups(P=NS). The amounts of blood transfused were 2.91$\pm$1.72 units in cell saver group, 4.82$\pm$1.72 units in control group. Composition of processed blood by cell saver was hemoglobin 17.4 gm%, hematocrit 56.4%, RBC 5,780,000/ul, WBC 9,900/ul, and platelet 33,000/ul. There was no complication related to cell saver. Conclusively, cell saver autotransfusion system is safe, effective method for reducing the homologous blood trasfusion in cardiac surgery.

  • PDF

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 자가 수혈체계[Cell Saver]의 이용 효과)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1312-1317
    • /
    • 1992
  • Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations. Between June 1991 and May 1992, 12 cases [Group I] were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve replacement. Control group [N=12, Group II] was selected to above similar operation during same period. The Cell Saver system [Haemonetics Corp.] was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally heparinized collecting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused subsequently. The patient receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. [Group I; 3519 $\pm$ 869, Group II; 4622 $\pm$ 856, Respectively; P=0.005] There were no clinical infections in the autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters. We conclude the autotransfusion using Cell Saver is effective for reducing of the hom-ologlous blood transfusion in cardiac surgery.

  • PDF

Autotransfusion Using Ccell Saver in Cardiac Surgery (개심술에서의 자가수혈기(Cell Saver)를 이용한 자가수혈)

  • 육을수
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.125-130
    • /
    • 1995
  • Autotransfusion system is a common method of reducing the need of intraoperative and postoperative homologous blood transfusion in cardiac operation. Between August 1991 and August 1993, a series of 51 adults undergoing open heart surgery was selected. Autotransfusion using Cell Saver [COBE Baylor Rapid Autologous Transfusion System was done with homologous blood transfusion in 15 cases [Group II or without homologous blood transfusion in 17 cases [Group III . The other 19 cases were taken without Cell Saver for control [Group I . The shed blood in the operative field, remained blood in the oxygenator after cardiopulmonary bypass, and blood drained from chest tubes in postoperative care were aspirated by means of a locally heparinized collection system. After the salvaged blood was washed and centrifuged, the processed blood subsequently reinfused. Composition of processed blood by Cell Saver was hemoglobin 16.9gm%, hematocrit 49%, RBC 5,140,000/ml, WBC 670/ml, and platelet 30,000/ml. In three group, hemoglobin, hematocrit, and platelet counts were decreased postoperatively, but no significant differences between three group. Postoperatively, the amounts of drainage from chest tubes was 543$\pm$121ml in Group I, 809$\pm$201ml in Group II, and 631$\pm$147ml in Group III. In Group II, there was large amount of drainage compared with Group I [p<0.05 . The amount of homologous blood transfused was 1116$\pm$219 ml in Group I, 791$\pm$183 ml in Group II [p<0.05 . The homologous blood was not transfused in 17 cases [53% with Cell Saver.Preoperative and postoperative, coagulation parameters showed no significant differences between three group. And there was no complication related to Cell Saver. We conclude that the autotransfusion using Cell Saver is effective for reducing the homologous blood transfusion in cardiac surgery.

  • PDF

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 Cell Saver 를 이용한 자가수혈의 효과)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.260-267
    • /
    • 1990
  • During a eight month period[from December, 1988 to July, 1989], a series of 35 adults undergoing redo-valve replacement or coronary artery bypass grafting was selected to an autotransfusion group[n=10] or a control group[n=25]. The Cell Saver System[Haemonetics Corp., Graintree, Mass] was employed for autotransfusion. With this system, all blood shed in the operative field before and after cardiopulmonary bypass and remained in cardiotomy reservoir after cardiopulmonary bypass was aspirated by means of a locally heparinized collecting system. After the salvaged blood was centrifuged, the resulting red cell concentrate subsequently reinfused. The patients receiving autologous blood required significantly less banked homologous blood than their controls[3213k1020 ml and 506051931 ml, respectively: p=0.001] There were no clinical infections in the autotransfusion group, although 40% of the cultures of processed blood were positive. And there was no apparent intergroup difference of the clinical and the hematologic and hemostatic laboratory findings. We conclude that autotransfusion using cell saver is effective for saving the homologous blood transfusion in cardiac surgery.

  • PDF

Clinical Study on the Blood Conservative Effect of Cell Saver Apparatus During OHS (개심술시 자가수혈기의 동종혈액 요구량의 저하 효과에 관한 연구)

  • Won, Yong-Soon;Ahn, Hyuk;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.28 no.4
    • /
    • pp.365-370
    • /
    • 1995
  • We studied blood salvage effect of Cell Saver Apparatus[CSA with adult cardiac patients. This study compares blood salvage in two groups of patients undergoing valve replacement or congenital cardiac operation.Group 1 is composed with 60 patients operated during 1991-1992 using CSA. Group 2 is composed with 60 patients operated during 1990-1991. No special effort was made to salvage blood in Group 2. The average requirements in Group 1 were approximately one-fourth the amount of RBC products by Group 2. The hospital course, blood chemistry level were comparable for the two groups. CSA produced blood was concentrated, well oxygenated blood and the average amount was 830 ml. Any complication was not detected in transfusion of CSA produced blood. This study shows that CSA allows safe and practical blood salvage during adult cardiac operations.

  • PDF

Cardiac Transplantation in a Jehovah's Wittness A Case Report (여호와의 증인의 심장이식 - 1례 보고 -)

  • 박국양;박철현
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.537-539
    • /
    • 1997
  • An orthotopic cardiac transplantation was successfully performed in a 40 year-old Jehovah's witness without use of any blood product. Preoperatively, the patient had been on coumadin to prevent left atrial thrombi and the INR(Internation Normalized Ratio)of prothrombin titre was 2.4. During the operation, cell saver was used for shed blood and aprotinin was admini tered intravenously for platelet function. Total postoperative drainage was 860cc and the lowest hemoglobin was 12.2 gmldl. Postoperative course was complicated by central nervous system infection by wisteria monocytogenes and two episodes of rejection, both of which were effectively treated. The patient is on his 5th postoperative month and doing well.

  • PDF

Open Heart Surgery without Transfusion (수혈 없이 시행한 개심술)

  • Kim, Kun-Il;Lee, Weon-Yong;Kim, Hyoung-Soo;Kim, Shin
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.184-192
    • /
    • 2009
  • Background: Although complications from transfusion are known to happen, transfusion is performed during most open heart surgeries. The aim of this study was to investigate the possibility of performing cardiac surgery without allogenic blood transfusion. Material and Method: Between January to August 2007, 44 consecutive patients who underwent open heart surgery with using various blood conservation methods were retrospectively enrolled. They were divided into group I (the onpump group, n=17) and group II (the offpump group, n=27). The blood conservation methods were intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. Antianemic agents were administered to all the patients postoperatively. We analyzed the possibility of bloodless operations, the causes of homologous transfusion, the serial change of the hematocrit and the postoperative chest tube drainage, and we compared the results between the two groups. If comparison between the two groups was not reasonable, then we compared two groups with the individual control groups I and II (49 patients) in 2006. Result: 40 (90.9%) of 44 patients were successfully operated on without transfusion and the success rate was 88.2% (15/17) for group I and 92.6% (25/27) for group II. There was no statistical difference between the two groups (p=NS). The causes of transfusion were 2 cases of postoperative bleedings, 1 case of intraoperative bleeding and 1 mistake of the indication for transfusion. There was no statistical difference of the total chest tube drainage (Group I: $417{\pm}359mL$, Group II: $451{\pm}237mL$) (p=NS), but the total chest tube drainages of the two groups were less than each of the control groups 1 and II (p<0.05). The lowest hematocrit level of Group I was $16.4{\pm}2%$, and this occurred just after infusion of cardioplegics and the hematocrits of both groups were recovered to the preoperative level at 2 months postoperatively. Conclusion: In this study, bloodless open heart surgery could be performed in 90.9% of the patients with intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. A combination of various blood conservation methods is the most important and bloodless cardiac surgery could be performed with meticulous bleeding control and strictly following the transfusion indications.

Clinical Efficacy of Intra-Operative Cell Salvage System in Major Spinal Deformity Surgery

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.53-60
    • /
    • 2019
  • Objective : The purpose of this study was to determine the efficacy of intra-operative cell salvage system (ICS) to decrease the need for allogeneic transfusions in patients undergoing major spinal deformity surgeries. Methods : A total of 113 consecutive patients undergoing long level posterior spinal segmental instrumented fusion (${\geq}5$ levels) for spinal deformity correction were enrolled. Data including the osteotomy status, the number of fused segments, estimated blood loss, intra-operative transfusion amount by ICS (Cell $Saver^{(R)}$, $Haemonetics^{(C)}$, Baltimore, MA, USA) or allogeneic blood, postoperative transfusion amount, and operative time were collected and analyzed. Results : The number of patients was 81 in ICS group and 32 in non-ICS group. There were no significant differences in demographic data and comorbidities between the groups. Autotransfusion by ICS system was performed in 53 patients out of 81 in the ICS group (65.4%) and the amount of transfused blood by ICS was 226.7 mL in ICS group. The mean intra-operative allogeneic blood transfusion requirement was significantly lower in the ICS group than non-ICS group (2.0 vs. 2.9 units, p=0.033). The regression coefficient of ICS use was -1.036. Conclusion : ICS use could decrease the need for intra-operative allogeneic blood transfusion. Specifically, the use of ICS may reduce about one unit amount of allogeneic transfusion in major spinal deformity surgery.