• Title/Summary/Keyword: Central corneal thickness

Search Result 18, Processing Time 0.027 seconds

Age and Sex Related Changes in Corneal Thickness and Anterior Corneal Curvature in Korean Young Population with Orbscan II Topography System

  • Lee, Dong-Hee;Kim, Douk-Hoon;Park, Seung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • This study investigated, using the Orbscan II topography system, the influence of age and sex related changes on the corneal thickness and anterior corneal curvature, more specifically the fine structure of the cornea, in a Korean young population. The Orbscan II topography system is a computer-assisted slit-beam scanning technology that can map the anterior section of the cornea. The mean central corneal thickness of all subjects was $547.532{\pm}44.529\;{\mu}m$. There was no statistical difference (p>0.5) in the mean central corneal thickness between males and females. Sex and age related changes in the mean central corneal thickness had no specific statistical difference (P>0.5). There was a negative correlation between the anterior corneal curvature and the central corneal thickness in all subjects, except for the twenty year olds. However, the thickness relationship between the mean central corneal and the eight paracentral corneal thicknesses had strong statistical differences in all subjects. Also age and sex related changes in the central corneal thickness and the anterior corneal curvature in all subjects had no statistically significant difference, except from 20-26 years old (p>0.05). This information could be a suitable reference basis for future studies in the young population of Asia and for the development of examination tools for corneal refractive surgery.

Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam (Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석)

  • Kim, Douk-Hoon;Bae, Han-Yong
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

The Changing Aspect of the Corneal Thickness by the Refractive Error (굴절이상도에 따른 각막두께의 변화 양상)

  • Park, Joon-Chul;Hwang, Jeong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.281-290
    • /
    • 2004
  • The purpose of this study is to investigate the correlation between the central corneal thickness and peripheral one, and the changing aspect of corneal thickness by the refractive error through the measure of central corneal thickness and peripheral one in myopic eyes. For this study, the central thickness and the peripheral one of the 198 eyes of 99 normal subjects was measured by Orbscan Topography System(Orbtex, Inc. USA). The latter was measured in each 2mm point distance of superior, inferior, nasal and temporal from the center of left & right eye. And the revealed results was analyzed according to sex, age, left & right eyes, and refractive error of the subjects. The mean central corneal thickness of the whole subjects was shown as $530.12{\pm}43.18{\mu}m$, and the mean peripheral ones were as follows : superior(SCT) $591.91{\pm}36.88{\mu}m$, inferior(ICT) $561.04{\pm}41.82{\mu}m$, nasal(NCT) $584.23{\pm}41.97{\mu}m$ and temporal(TCT) $567.35{\pm}43.25{\mu}m$. From this, we can see that the mean central corneal thickness and the peripheral ones show significantly difference, but there is no statistically Significant difference in the corneal thickness according to refractive error, age, sex, and left & right.

  • PDF

Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea (한국인 20세부터 24세까지 각막 두께와 안압의 분석)

  • Douk Hoon Kim;Kishor Sapkota
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

Comparison of Corneal Edema Induced by Material of Contact Lens (콘택트렌즈의 재질별 각막부종의 비교)

  • Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Tae-Hun;Kim, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.151-156
    • /
    • 2015
  • Purpose: This study has been compared the degree of corneal edema arising from the material of the lens after wearing the recommended wearing time for the contact lens. Methods: For the study, 43 adults of 77 eyes who did not use drugs and have not any disease participated. Three types of lenses including narafilcon A, HEMA, and silicone hydrogel material regular replaceable lenses were used. Central corneal thickness was measured before and after 8 hours from wearing lenses using Pentacam. The degree of corneal edema was determined by the difference before and after wearing. Results: The average corneal edema of narafilcon A, HEMA material lens, and silicone hydrogel material regular replaceable lens were $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$, respectively. The central corneal thickness after wearing narafilcon A was not statistically significant with the central corneal thickness before wearing the lens. Central corneal thickness before and after wearing HEMA material lens and silicone hydrogel material regular replaceable lens were statistically significant. Conclusions: The amount of corneal edema induced by silicone hydrogel material regular replaceable lens was no statistically significant difference to the amount of corneal edema induced by HEMA material lens, but there was significant difference to narafilcon A. Therefore, it is judged to be careful not to exceed the recommended wearing time depending on the composition of the contact lens material.

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

Intraocular Pressure and Its Determinants in Subjects With Type 2 Diabetes Mellitus in India

  • Biswas, Sayantan;Raman, Rajiv;Koluthungan, Vaitheeswaran;Sharma, Tarun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.44 no.4
    • /
    • pp.157-166
    • /
    • 2011
  • Objectives: This study was conducted to show the intraocular pressure (IOP) distribution and the factors affecting IOP in subjects with type 2 diabetes mellitus (DM) in India. Methods: We measured the anthropometric and biochemical parameters for confirmed type 2 DM patients. A comprehensive ocular examination was performed for 1377 subjects aged > 40 years and residing in Chennai. Results: A significant difference in IOP (mean ${\pm}$ standard deviation) was found between men and women ($14.6{\pm}2.9$ and $15.0{\pm}2.8$ mmHg, p = 0.005). A significantly elevated IOP was observed among smokers, subjects with systemic hypertension and women with clinically significant macular edema (CSME). After a univariate analysis, factors associated significantly with higher IOP were elevated systolic blood pressure, elevated resting pulse rate and thicker central corneal thickness (CCT). In women, elevated glycosylated hemoglobin was associated with a higher IOP. After adjusting for all variables, the elevated resting pulse rate and CCT were found to be associated with a higher IOP. Conclusions: Systemic hypertension, smoking, pulse rate and CCT were associated with elevated intraocular pressure in type 2 DM. Women with type 2 DM, especially those with CSME, were more prone to have an elevated IOP.

Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes

  • Lee, Hun;Kang, David Sung Yong;Ha, Byoung Jin;Choi, Jin Young;Kim, Eung Kweon;Seo, Kyoung Yul;Kim, Tae-im
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1115-1122
    • /
    • 2018
  • Purpose: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. Materials and Methods: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. Results: This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased CorvisIOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). Conclusion: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.