• Title/Summary/Keyword: Change of Eccentricity

Search Result 68, Processing Time 0.027 seconds

Electromechanical Characteristics of a Squirrel Cage Induction Motor due to Broken Rotor Bars and Rotor Eccentricity (회전자 바 개방과 회전자 편심에 의한 단삼 유도 전동기의 전기 및 기계적 특성 해석)

  • Park, Sang-Jin;Jang, Jeong-Hwan;Jang, Geon-Hui;Lee, Yong-Bok;Kim, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.425-433
    • /
    • 2002
  • This research investigates the electromechanical characteristics of a sing1e-phase squirrel cage induction motor due to broken rotor bars and rotor eccentricity. Numerical analysis is performed by solving the nonlinear time-stepping finite element equation coupled with the magnetic field equation, circuit equation and mechanical equation of motion. It shows that the asymmetry of magnetic flux due to the broken rotor bars and rotor eccentricity introduce a change in the stator current, torque, speed, magnetic force and vibration of a rotor at the same time. However, even in the existence of rotor eccentricity, 3 broken rotor bar introduces a dominant change in the magnetic force and rotor displacement, i.e., beating phenomenon in time domain and sideband frequencies in frequency spectra, respectively.

In-Structure Response Spectra of Seismically Isolated Shear Buildings Considering Eccentricity Effect (면진된 전단 거동 구조물의 층응답스펙트럼에 대한 편심효과)

  • Lee, Seung Jae;Kim, Jung Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • For important structures such as nuclear power plants, In-Structure Response Spectrum (ISRS) analysis is essential because it evaluates the safety of equipment and components installed in the structure. Because most structures are asymmetric, the response can be affected by eccentricity. In the case of seismically isolated structures, this effect can be greater due to the difference between the center of mass of the structure and the center of rigidity of the isolator layer. Therefore, eccentricity effects must be considered when designing or evaluating the ISRS of seismically isolated structures. This study investigated the change of the ISRS of an isolated structure by assuming accidental eccentricity. The variables that affect the ISRS of the isolated structure were analyzed to see what additional impact they had due to eccentricity. The ISRS of the seismically isolated structure with eccentricity was amplified more than when there was non-eccentricity, and it was boosted more significantly in specific period ranges depending on the isolator's initial stiffness and seismic intensity. Finally, whether the displacement requirement of isolators can be applied to the variation of the ISRS due to eccentricity in the design code was also examined.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Seismic Response Evaluation of Seismically Isolated Nuclear Power Plant with Stiffness Center Change of Friction Pendulum Systems (마찰진자시스템의 강성중심 변화에 따른 면진된 원전 구조물의 지진응답평가)

  • Seok, Cheol-Geun;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.265-275
    • /
    • 2017
  • In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.

Tolerance Analysis Method of Camera Optics Using Floating System (플로팅 시스템이 적용된 카메라 광학계의 공차 분석)

  • Son, Hyun Jun;Ryu, Jae Myung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.303-309
    • /
    • 2022
  • Since the pixel size of the image sensor used in optical systems is gradually decreasing, the resolution specification of the optical system should be inevitably higher. If aberration change according to the eccentricity of a specific lens group occurs, only the amount of eccentricity of a specific lens group may be calculated with the traditional resolution adjustment method so that the aberration of the optical system is minimized to a certain extent. As a result, it is possible to increase the resolution of the optical system and to respond to a sensor with a large number of pixels. However, in the traditional method, there should be no change in specific aberration due to the eccentricity of a specific lens group. In this paper, we propose a new method to eliminate such a limitation of the traditional method in a camera optical system with a floating system, which is to choose and control the arbitrary two lens groups to easily minimize the eccentricity of the optical system in order to obtain an optical system with high resolution.

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.

Design of Elliptical Lobe Type Gear with Involute Profile (타원계 엽형기어의 설계 및 동특성에 관한 연구)

  • 유명섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.4
    • /
    • pp.7-14
    • /
    • 1998
  • Noncircular gears have been used for obtaining the modified anglualr velocity ratio between parallel axes. The elliptical gear, which is a kind of noncircular gears, makes use of ellipse as a pitch curve, and is applied for the measurement of the discharge of liquid. The applications of an elliptical gear are more advantageous than any other mechanism as like a crank-slider linkage or a cam mechanism in view of the accuracy and the reliability to transmit the prescribed motion. In this paper, acceding to the theoretical involute tooth profile, two pairs of the elliptical gears were manufactured by using CNC wire electronic discharge machine. The proper ranges of the operating pressure angle and of module not to generate under cutting are studied on the change of the eccentricity, because it is the eccentricity of the pitch curve that determines most of the characteristics of the elliptical gear and then the vibration analysis is executed for the verification of harmonious rotating.

  • PDF

Frozen Orbits Construction for a Lunar Solar Sail

  • Khattab, Elamira Hend;Radwan, Mohamed;Rahoma, Walid Ali
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • Frozen orbit is an attractive option for orbital design owing to its characteristics (its argument of pericenter and eccentricity are kept constant on an average). Solar sails are attractive solutions for massive and expensive missions. However, the solar radiation pressure effect represents an additional force on the solar sail that may greatly affect its orbital behavior in the long run. Thus, this force must be included as a perturbation force in the dynamical model for more accuracy. This study shows the calculations of initial conditions for a lunar solar sail frozen orbit. The disturbing function of the problem was developed to include the lunar gravitational field that is characterized by uneven mass distribution, third body perturbation, and the effect of solar radiation. An averaging technique was used to reduce the dynamical problem to a long period system. Lagrange planetary equations were utilized to formulate the rate of change of the argument of pericenter and eccentricity. Using the reduced system, frozen orbits for the Moon sail orbiter were constructed. The resulting frozen orbits are shown by two 3Dsurface (semi-major, eccentricity, inclination) figures. To simplify the analysis, we showed inclination-eccentricity contours for different values of semi-major axis, argument of pericenter, and values of sail lightness number.

Wear Analysis of Journal Bearings in a Misaligned Shaft During Motoring Start-up and Coast-down Cycles - Part I: Study on the Change in Oil Film Thickness at Potential Wear Regions (모터링 시동 및 시동정지 사이클에서 경사진 축을 갖는 저어널 베어링의 마모 해석 - Part I: 마모발생 가능영역에서의 유막 변화 연구)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.33 no.4
    • /
    • pp.153-167
    • /
    • 2017
  • The aim of this study is to find the change in trend in the eccentricities of two journal bearings supporting the crankshaft of a single cylinder engine and the degree of misalignment of the shaft. We analyze the change in oil film thickness considering the wear scar under mixed-elasto-hydrodynamic lubrication regime at potential wear regions. For this, we first calculate the central eccentricities of the two journal bearings by using the mobility method. Then we calculate the outer end eccentricity by using the geometry of the bearings. Further, the tilting angle and degree of misalignment of the shaft are calculated by using the eccentricities of the two bearings. We show that the eccentricity of bearing #1, on which higher load is applied, increases at the beginning of the start-up cycle and during the coast-down cycle. However, the eccentricity of bearing #2, on which lower load is applied, decreases at the beginning of the start-up cycle and increases during the coast-down cycle. From the results of the analysis of oil film thickness, we show that the mixed-elasto-hydrodynamic lubrication regime for a misaligned shaft is at the initial stages of the start-up cycle for both bearing #1 and #2 and at the final stage of the coast-down cycle for only bearing #1.

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.