• Title/Summary/Keyword: Chemical durability

Search Result 756, Processing Time 0.023 seconds

Chemical Durability of Simulated Waste Glasses (모의 폐기물유리의 화학적 내구성)

  • 현상훈;송원선
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.4
    • /
    • pp.521-531
    • /
    • 1989
  • The dependence of the chemical durability of simulated waste glasses containing the simplified waste similar to the SRP waste on compositions of host glasses, amounts of waste loading, and kinds of leachants has been investigated as a basic study on the waste immobilization through vitrification. The maximum limit of the amount of waste loading for glassforming with the host sodium borosilicate glasses selected in this study was 50wt%. The chemical durability of waste glasses whose host glass belonged to the immiscible composition region was much higher than that of waste glasses whose host glass belonged to the miscible composition region. The former waste glass showed lower chemical durability in deionized and silicate waters than in brine, while the latter glass showed the lowest chemical durability in deionized and silicate waters than in brine, while the latter glass showed the lowest chemical durability in silicate water. It was also observed that the total leaching rates in brine were noticeably small in comparison with those in other solutions. The composition of the host borosilicate glass which was suitable for the treatment of the waste through vitrification was found to be 25 Na2O-5B2O3-70SiO2(wt.%).

  • PDF

Enhancement of Membrane Durability in PEMFC by Fucoidan and Tannic Acid (후코이단과 탄닌산에 의한 PEMFC 고분자막의 내구성 향상)

  • Mihwa Lee;Sohyeong Oh;Cheun-Ho Chu;Young-Sook Kim;Il-Chai Na;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.45-51
    • /
    • 2023
  • In order to improve the durability of the PEMFC(Proton Exchange Membrane Fuel Cells) polymer membrane, a radical scavenger and a support are used. In this study, the durability of membranes containing fucoidan extracted from seaweeds and tannic acid serving as a crosslinking agent is evaluated to improve chemical and physical durability. Physical durability is evaluated by measuring tensile strength, and chemical durability is measured by Fenton experiment. Membrane and electrode assembly (MEA) is prepared and mechanical and chemical durability are measured through accelerated durability evaluation in the cell. The tensile strength measurement showed that fucoidan and tannic acid can improve the mechanical durability of the membrane by improving the strain rate and yield strength. It is shown in Fenton experiment that fucoidan acts as a radical scavenger. As a result of the accelerated durability test in the unit cell, fucoidan improved both chemical and mechanical durability, increasing the accelerated durability evaluation time by 38.1% compared to the additive-free membrane. When tannic acid is added, the durability of the polymer membrane is improved by 13.9% by improving the mechanical durability.

Reducing the Test Time for Chemical Durability of PEMFC Polymer Membrane (PEMFC 고분자막의 화학적 내구성 평가시간 단축)

  • Oh, Sohyeong;Cho, Wonjin;Lim, Daehyeon;Yoo, Donggeun;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.333-338
    • /
    • 2021
  • The durability of the PEMFC stack for large commercial vehicles should be more than 5 times that for passenger vehicles. If the Chemical Accelerated Stress Test (AST) of PEMFC(Proton Exchange Membrane Fuel Cells) membrane for passenger cars is applied as it is for large commercial vehicles, there is a problem that the AST time becomes more than 2,500 hours. In order to shorten the AST time of DOE (Department of Energy), the chemical durability of the polymer membrane was evaluated using oxygen instead of air as a cathode gas. In this study, Nafion XL was used as a polymer membrane to evaluate accelerated durability under OCV, 90?, RH 30%, H2/(air or oxygen) conditions. Among the DOE membrane durability target criteria, the decrease rate of short resistance was the fastest. By using oxygen instead of air, the degradation rate of the polymer membrane was accelerated while being less affected by electrode deterioration, reducing the polymer membrane durability evaluation time to less than half.

Effect of Influent Gas on Mechanical Acceleration Durability Test of PEMFC Polymer Membrane (PEMFC 고분자막의 기계적 가속 내구 평가 과정에서 유입 가스의 영향)

  • Oh, Sohyeong;Hwang, Byungchan;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.321-326
    • /
    • 2022
  • As the thickness of the polymer membrane of PEMFC(Proton Exchange Membrane Fuel Cells) is getting thinner for PEMFC performance and price reduction, research on improving durability has become more important. In the durability evaluation of membranes, the mechanical durability evaluation time is more than twice that of the chemical durability evaluation time, so it is necessary to select the durability evaluation conditions well. In this study, we tried to check how much the mechanical durability evaluation time changes when there is a difference in the inflow gas type and flow rate in the mechanical durability evaluation protocol (Wet/Dry). When nitrogen was used at a flow rate of 2,000 mL/min, the evaluation time increased by 1.25 times compared to when air was used. An increase in the degradation rate of the electrode Pt was the main factor when air was used. When the flow rate was reduced to 800 mL/min, the air and nitrogen evaluation times increased by 1.5 times and 1.2 times, respectively.

Effect of Change in Wet/Dry Time of PEMFC Membrane Durability Test Protocol Using Oxygen as Cathode Gas (Cathode 산소 공급조건에서 고분자막 내구평가 프로토콜의 가습/건조 시간 변화의 영향)

  • Lim, Daehyeon;Oh, Sohyeong;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.16-20
    • /
    • 2021
  • Since the durability evaluation for improving the durability of PEMFC polymer membranes is very important for the development of PEMFC, research and development of the polymer membrane durability evaluation protocol (AST) continues. Recently, DOE's polymer membrane chemical/mechanical durability evaluation AST was developed and applied to Nafion XL for review. In order to shorten the evaluation time, oxygen was used as a cathode gas instead of air, and it was finished in 144 hours. Since DOE AST has a large number of voltage changes with 45 seconds of humidification and 30 seconds of drying, the degradation of the electrode has more influence on the MEA durability. Therefore, one cycle time was lengthened with 60sec of wet/300sec of dry, and the drying time was made longer than the humidification time to further deteriorate the polymer membrane, and it was finished in 240 hours. It was confirmed that the DOE AST for evaluation of the durability of the polymer membrane was accompanied by electrode degradation.

Chemical Durability Test of Thin Membrane in Proton Exchange Membrane Fuel Cells (고분자전해질 연료전지에서 박막의 화학적 내구성 평가)

  • Sohyeong Oh;Donggeun Yoo;Sunggi Jung;Jihong Jeong;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.362-367
    • /
    • 2023
  • Recently, research and development of proton exchange membrane fuel cells (PEMFC) membranes are progressing in the direction of thinning to reduce prices and improve performance. Demand for hydrogen-powered vehicles for commercial vehicles is also increasing, and their durability should be five times greater than those for passenger vehicles. Despite the thinning of the membranes, the durability of the membranes must be increased five times, so the improvement of the durability of the membranes has become more important. Since the acceleration durability evaluation time also needs to be shortened, the protocol using oxygen instead of air in the existing protocol was applied to a 10 ㎛ thin membrane to evaluate durability. The accelerated durability test (Open circuit voltage holding) was terminated at 720 hours. If the air-based department of energy (DOE) protocol was used, a lifespan of 450,000 km of driving hours would be expected, with a durability of about 1,500 hours. During the chemical durability evaluation, the active area of the electrode decreased by 51%, suggesting that catalyst degradation had an effect on membrane durability. Reducing the catalyst degradation rate is expected to increase membrane durability.

Durability enhancement of anion exchange membranes for water electrolysis: an updated review

  • Akter, Mahamuda;Park, Jong-Hyeok;Kim, Beom-Seok;Lee, Minyoung;Jeong, Dahye;Shin, Jiyun;Park, Jin-Soo
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.319-327
    • /
    • 2022
  • Ion exchange membranes have been developed from laboratory tools to industrial products with significant technical and trade impacts in the last 70 years. Today, ion exchange membranes are successfully applied for water and energy for different electro-membrane processes. Hydrogen could be produced by electrochemical water splitting using renewable energy, for example, solar, biomass, geothermal and wind energy. This review briefly summarizes the recent studies reporting the state-of-the-art anion-exchange membrane water electrolysis, especially focusing on the enhancement of the durability of anion-exchange membranes. Anion-exchange membrane water electrolysis could be used as inexpensive non-noble metal electrocatalysts that are capable of producing low cost of hydrogen. However, the main challenge of anion-exchange membrane water electrolysis is to increase the performance and durability. In this mini review, the limiting factors of the durability and the technology enhancing the durability will be discussed for anion exchange membrane water electrolysis.

Preparation and Characterization of the Polymeric Antioxidant for Improving the Chemical Durability of Polymer Electrolyte Membranes (고분자 전해질 막의 화학적 내구성 향상을 위한 고분자형 산화방지제 제조 및 특성 분석)

  • LEE, BYEOL-NIM;KODIR, ABDUL;LEE, HYEJIN;SHIN, DONGWON;BAE, BYUNGCHAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.308-314
    • /
    • 2021
  • Chemical durability issue in polymer electrolyte membranes has been a challenge for the commercialization of polymer electrolyte membrane fuel cells (PEMFCs). In this study, we proposed a manufacturing method of Nafion composite membrane containing a stable polyimide antioxidant to improve the chemical durability of the membrane. The thermal casting of the Nafion solution with poly (amic acid) induced polyimide reaction. We evaluated proton conductivity, oxidative stability with ex-situ Fenton's test, and fluoride ion emission to analyze the effect of polyimide antioxidants. We confirmed that incorporating the polyimide antioxidant improves the chemical durability of the Nafion membrane while maintaining inherent proton conductivity.

Durability Evaluation of Grout in Cablebolt System (케이블볼트 충전재의 내구성 평가)

  • Choi, Jung-In;Kim, Won-Keun;Jeon, Jae-Hyun;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.553-561
    • /
    • 2010
  • Like the shotcrete can be deteriorated by chemical compounds as service years increase, the grout which is used to fasten the cablebolt(rockbolt) system in the underground structures also can be deteriorated by chemical compounds such as sulphate and/or chloride contained in groundwater during service years. This can induce issues on the long term durability of cablebolt(rockbolt) system and consequently on the stability of underground structures. In this study, the deteriorations of long term durability of cement mortar grout by each chemical compound of sulphate or chloride are studied experimentally and also complex deterioration by the mix of sulphate and chloride is investigated. Based on the results obtained in this study, the characteristics and prediction of deterioration of long term durability of cement mortar grout for cablebolt(rockbolt) system are suggested.

  • PDF

An Experimental Study on Solidifying Mat of System Improving for Durability Improving (고화매트의 내구성 향상을 위한 시스템 개선의 실험적 연구)

  • Hong, Sung-Rog;Lee, Jung-Yoon;Kim, Young-Sam;Park, Hun-Il;Cho, Byoung-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.108-109
    • /
    • 2014
  • The purpose of this study is to enhance durability of solidifying mat. solidifying mat excellent mechanical properties of geotextile. multi-layer coating system is applied to the mat and the chloride ions penetration resistance, chemical resistance, accelerated carbonation test were evaluated by testing the durability. Durability test results are as follows. chloride ions penetration resistance results are coated mat is approximately 70 % lower than plain. chemical resistance test results are coated mat no discoloration. accelerated carbonation test results are coated mat is approximately 90 % lower than the plain.

  • PDF