• 제목/요약/키워드: Cleaning sponge ball

검색결과 8건 처리시간 0.025초

Reduction of energy demand for UF cross-flow membranes in MBR by sponge ball cleaning

  • Issa, Mohammad;Geissen, Sven-Uwe;Vogelpohl, Alfons
    • Membrane and Water Treatment
    • /
    • 제12권2호
    • /
    • pp.65-73
    • /
    • 2021
  • Sponge ball cleaning can generate an abrasion effect, which leads to an attractive increasing in both permeate flux and membrane rejection. The aim of this study was to investigate the influence of the daily sponge ball cleaning (SBC) on the performance of different UF cross-flow membrane modules integrated with a bioreactor. Two 1"-membrane modules and one 1/2"-membrane module were tested. The parameters measured and controlled are temperature, pH, viscosity, particle size, dissolved organic carbon (DOC), total suspended solids (TSS), and permeate flux. The permeate flux could be improved by 60%, for some modules, after 11 days of daily sponge ball cleaning at a transmembrane pressure of 350 kPa and a flow velocity of 4 m/s. Rejection values of all tested modules were improved by 10%. The highest permeate flux of 195 L/㎡.h was achieved using a 1"-membrane module with the aid of its negatively charged membrane material and the daily sponge ball cleaning. In addition, the enhancement in the permeate flux caused by daily sponge ball cleaning improved the energy specific demand for all tested modules. The negatively charged membrane showed the lowest energy specific demand of 1.31 kWh/㎥ in combination with the highest flux, which is a very competitive result.

스펀지 볼을 이용한 원전용 복수기 튜브 세정 시스템 개발 (Development on Cleaning System of Condenser for Nuclear Power Plant by Using Sponge Ball)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.21-26
    • /
    • 2015
  • This study presents a development of the cleaning system in a nuclear power plant condenser. The tube cleaning system is very important equipment in a power plant condenser. Specially, removal of the fouling is a key process in the condenser tube. The objective of this study is development of a ball collector system for cleaning a condenser by using a sponge ball. This study uses CFD in order to optimize design of the ball strainer screen. Through the CFD, the implication of the ball strainer screen for static pressure distribution is examined. Results of research, this study have developed a 1/5 scale model for application to the power plant and developed a performance test equipment.

발전소용 CTCS 내 Vortex Promoter 설계 변수에 따른 세척용 스폰지 볼 회수성능 분석 (Analysis of Cleaning Sponge Ball Recovery Performance According to Vortex Promoter Design Parameters in CTCS for Power Plant)

  • 정다운;이승율;김동선;서현규
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.126-133
    • /
    • 2023
  • This study analyzes the flow characteristics and sponge ball recovery performance in a ball strainer according to vortex promoter design variables through flow-particle analysis based on actual experiments to derive a method for improving the recovery rate of cleaning sponge balls of CTCS applied to existing power plants. Based on the ball strainer in CTCS used in the power plant, the experiment was conducted by changing the design factor of the improved shape. In addition, flow and particle analysis were performed under the same conditions as the experiment to numerically the flow characteristics and recovery rate in the ball strainer according to the design factor of the vortex promoter. As a result of the study, it was confirmed that the recovery performance was improved by about 3% by changing the design height of the Vortex promoter. And when comparing the difference between maximum and minimum recovery rate, it was found that the effect on the recovery performance increased slightly according to the distance condition compared to the vortex promoter design height condition.

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

버블 유동층과 세정 볼을 이용한 폐수 열원 히트펌프 시스템 증발기의 관 외측 오염 저감 장치에 관한 연구 (A fouling mitigation device for a wastewater heat recovery heat pump system using a bubbling fluidized bed with cleaning sponge balls)

  • 김종수;김도빈;김준하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.152-156
    • /
    • 2016
  • 폐수 열원 히트펌프 시스템은 목욕탕, 공장 또는 하천수 등을 히트펌프의 열원으로 사용한다. 증발기는 폐수로부터의 오염을 완화시키기 위하여 휜이 없는 나관식(bare tube) 열교환기가 주로 사용되고 있다. 대부분의 열 저항은 관외를 흐르는 폐수측에 생성되는 파울링에 의한 것이며, 히트펌프의 성능을 급격하게 감소시킨다. 따라서 본 연구에서는 나관식 열교환기 하부에서 버블 유동층을 형성시키고 세정 볼을 사용하여 관 외측의 파울링을 저감시키는 장치를 개발하였다. 실험 조건으로, 냉수온도 $20^{\circ}C$, 폐수 온도 $40^{\circ}C$, 관 내측 유량 100L/h, 수조 내 물의 양 50L, 열교환기 면적 $0.161m^2$ 이다. 실험결과 세정 볼 없이 버블유동층만 형성한 경우에는 버블유동층이 없는 경우에 비해 파울링에 의해 생성된 열 저항이 약 56% 감소되었으며, 세정 볼의 개수 밀도가 8,000(Number of $ball/m^3$) 일 때, 파울링에 의해 생성된 열 저항은 버블유동층 및 세정 볼이 없을 때와 비교하여 약 86% 감소되었다.

튜브 클리닝 시스템 내부의 유동 특성에 관한 수치해석적 연구 (The Numerical Analysis of Fluid Flow in the Tube Cleaning System)

  • 정경철;이치우
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2014
  • The numerical analysis of fluid flow in the tube cleaning system is examined. The working flow used in this study is seawater, and the temperature change is not considered as the temperature change of seawater in the tube cleaning system is negligible. Also, the analysis is performed under the assumption of steady state. The screens of complicated morphologies are simplified for the analysis, and only one fourth of the tube cleaning system is modeled as the system has a symmetrical shape. The velocity inlet boundary condition is employed for the seawater inlet, whereas the outflow boundary condition is employed for two seawater outlets. In applying the outflow boundary condition for the system with more than two outlets, the flow rate can be arbitrarily assigned. In the analysis, the finite-volume method based numerical analysis tool, the pressure based solver, the standard k-$\varepsilon$ model are utilized, and the under relaxation factor is modified appropriately. From the analysis, the distribution of velocity vectors, pressure and path lines are obtained, and the physical characteristics of fluid flow in the tube cleaning system is well-examined.

압축식 냉동기에서 세정장치에 의한 파울링 억제효과 (The Effect on Fouling Reduction by the Cleaning System in Compressed Type Refrigerator)

  • 이윤표;강상우
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.482-489
    • /
    • 2001
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

  • PDF

원자력 및 화력 발전소의 해수 담수 설비 중 콘덴서 튜브 클리닝 시스템(CTCS)의 스크린 파손사례 분석 (The failure Analysis of fractured Screen of Condenser Tube Cleaning for Seawater Desalination in Nuclear and Thermal Power Plants)

  • 장복수;임영민;김남훈;고진현
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 2부
    • /
    • pp.391-393
    • /
    • 2011
  • 본 연구에서는 원자력 발전 및 화력 발전소에서 Turbine 운전 시 열교환기 및 콘덴서에 증기를 응축시 열효율을 높여주기 위해 콘덴서 Tube 내에 이물질 및 스케일을 Sponge Ball을 이용하여 자동으로 제거하는 장치로서 콘덴서 튜브 클리닝 시스템(CTCS)에 사용되고 있는 Screen 재료인 Duplex Stainless Steel UNS S31803의 파손사례에 대해 연구하였다. 파손원인 분석은 스크린의 강도해석, 재료의 화학분석시험, 조직시험 및 점용접부의 신뢰성 시험(Peel-off test)으로 수행되었고 저항용접부의 용접 불량 때문에 발생하였을 확인하였다.

  • PDF